UFDC Home | Search all Groups | Arts | Living in Florida | Architecture & Landscape Design | UF Architecture Archives | | Help |
Material Information
Subjects
Record Information
|
Full Text |
GENERAL NOTES 100. DESIGN CRITERIA 100.1 DESIGN BUILDING CODE: 1. 2001 FLORIDA BUILDING CODE 100.2 GRAVITY DESIGN LOADS: 1. UVE LOADS: a. ROOF ......... ........................20 PSF b. ELEVATED FLOORS ...... ....................40 PSF c. SLAB ON GRADE . . . . . . . . . . 100 PSF 100.3 LATERAL LOADS: 1. WIND LOADS (2001 FBC, ASCE 7-98) a. V = 110 MPH b. EXPOSURE CATEGORY: B c. ENCLOSURE CLASSIFICATION: "ENCLOSED" d. BUILDING CATEGORY: II e. IMPORTANCE FACTOR (I) = 1.0 f. INTERNAL PRESSURE COEFFICIENT: (GCpi) = M 0.18 g. COMPONENTS AND CLADDING PRESSURES: SEE "COMPONENTS AND CLADDING WIND LOADS" TABLE, AND "COMPONENTS AND CLADDING WIND PRESSURE DIAGRAM" 110. GENERAL 110.1 THIS DRAWING HAS BEEN PRODUCED ENTIRELY ON ATLANTIC ENGINEERING SERVICES CADD SYSTEM. ANY OTHER LETTERING, LINES OR SYMBOLS, OTHER THAN PROFESSIONAL STAMPS AND SIGNATURES, HAVE BEEN MADE WITHOUT THE AUTHORIZATION OF ATLANTIC ENGINEERING SERVICES AND ARE INVAULID. 110.2 THE STRUCTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL STRUCTURAL FEATURES, UNLESS NOTED OTHERWISE. THE ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL DIMENSIONS. 110.3 THE METHOD AND FREQUENCY OF ATTACHING MECHANICAL EQUIPMENT UNITS, ETC.. TO THE STRUCTURAL ELEMENTS SHALL BE SUBJECT TO THE STRUCTURAL ENGINEER'S REVIEW AND APPROVAL. 110.4 THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, ETC., AND SHALL NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES, ADDITIONAL INFORMATION, ETC., BEFORE BEGINNING THE WORK. 110.5 ALL STRUCTURAL WORK SHALL BE INSPECTED IN ACCORDANCE WITH THE BUILDING CODE AND ALL LOCAL ORDINANCES. THE OWNER SHALL ENGAGE AN EXPERIENCED, QUALIFIED INSPECTION AGENCY, SUBJECT TO THE REVIEW OF THE ARCHITECT, TO PERFORM ALL INSPECTION WORK, AS REQUIRED. THRESHOLD BUILDINGS SHALL BE INSPECTED BY A UCENCED THRESHOLD INSPECTOR IN ACCORDANCE WITH THE THRESHOLD INSPECTION PLAN. 110.6 STEP FOOTINGS BELOW ALL SANITARY AND WATER LINES. PROVIDE STEPS IN THE FOUNDATIONS IN ACCORDANCE WITH THE TYPICAL DETAILS. COORDINATE THE EXACT LOCATION AND ELEVATION OF THE PLUMBING LINES WITH THE MECHANICAL AND PLUMBING DRAWINGS AND CONTRACTORS. PROVIDE SLEEVES IN THE FOUNDATION WALLS AS REQUIRED FOR PIPE PENETRATIONS. 120 SHOP DRAWINGS 120.1 THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW BY ATLANTIC ENGINEERING SERVICES AND THE PROJECT ARCHITECT. SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL COMPONENTS INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: a. FABRICATED STRUCTURAL STEEL b. REINFORCING STEEL FOR CONCRETE AND MASONRY c. CONCRETE AND/OR MASONRY POST-INSTALLED ANCHORS d. PREFABRICATED WOOD TRUSSES e. ENGINEERED WOOD COMPONENTS (LAMINATED VENEER LUMBER) 120.2 SHOP DRAWINGS TO BE SUBMITTED SHALL PROVIDE COMPLETE INFORMATION FOR THE PRODUCTS OR COMPONENTS TO BE SUPPLIED. SUBMITTAL INFORMATION SHALL INCLUDE, BUT NOT BE LIMITED TO: MEMBER SIZES AND DIMENSIONS; GRADES OF MATERIAL FURNISHED; MATERIAL PREPARATION REQUIRED; MATERIAL FINISH AND MATERIAL COATINGS TO BE FURNISHED; INFORMATION REGARDING CUTS, COPES AND HOLES REQUIRED FOR OTHER TRADES; END CONNECTIONS; CAMBER AND OTHER DEVIATION FROM LINE; SPECIAL ERECTION AND/OR INSTALLATION PROCEDURES INCLUDING REQUIREMENTS FOR TEMPORARY STABILIZATION. 120.3 THE CONTRACTOR SHALL SUBMIT PRINTED COPIES OF SHOP DRAWINGS FOR REVIEW BY ATLANTIC ENGINEERING SERVICES. PRINTED COPIES OF SHOP DRAWINGS SHALL CONSIST OF TWO (2) NON-REPRODUCIBLE PRINTS AND ONE (1) REPRODUCIBLE TRACING/SEPIA. UPON THE COMPLETION OF THE SHOP DRAWING REVIEW, ONE (1) PRINT AND ONE (1) TRACING/SEPIA SHALL BE RETURNED TO THE PROJECT ARCHITECT FOR DISTRIBUTION TO THE CONTRACTOR. 120.4 THE CONTRACTOR SHALL NOT DIRECTLY INCORPORATE THE STRUCTURAL DRAWINGS, OR PORTIONS THEREOF, INTO SHOP DRAWINGS OR ERECTION DRAWINGS TO BE SUBMITTED FOR THIS PROJECT WITHOUT THE EXPRESS PERMISSION OF ATLANTIC ENGINEERING SERVICES. SUBMITTED SHOP DRAWINGS WHICH CONTAIN COPIES OR REPRODUCTIONS OF ANY PORTION OF THE STRUCTURAL DRAWINGS WITHOUT THE EXPRESS WRITTEN PERMISSION OF ATLANTIC ENGINEERING SERVICES WILL BE RETURNED REJECTED. IF PERMISSION TO USE THE STRUCTURAL DRAWINGS IS GRANTED BY ATLANTIC ENGINEERING SERVICES, THE CONTRACTOR SHALL BE REQUIRED TO ENTER INTO A WRITTEN AGREEMENT WITH ATLANTIC ENGINEERING SERVICES AND TO PAY A SERVICE FEE TO USE THE STRUCTURAL DRAWINGS IN THE PREPARATION OF SHOP DRAWINGS. 120.5 THE REVIEW OF SHOP DRAWINGS AND OTHER SUBMITTALS FOR THIS PROJECT IS FOR CONFORMANCE WITH THE DESIGN CONCEPT AND FOR GENERAL COMPLIANCE WITH THE INFORMATION CONTAINED IN THE CONTRACT DOCUMENTS. COMMENTS REGARDING THESE SUBMITTALS DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PERFORMING HIS WORK IN A SAFE AND SATISFACTORY MANNER. 200 FOUNDATIONS GENERAL 200.1 200.2 THE CONTRACTOR SHALL OBSERVE WATER CONDITIONS AT THE SITE AND TAKE THE NECESSARY PRECAUTIONS TO INSURE THAT THE FOUNDATION EXCAVATIONS REMAIN DRY DURING CONSTRUCTION. CONTRACTOR TO PROVIDE FOR DEWATERING AS NECESSARY. 200.3 THE CONTRACTOR SHALL USE EXTREME CAUTION DURING EXCAVATION. SUCH EXCAVATION SHALL BE PERFORMED IN SUCH A MANNER AS TO MAINTAIN THE STRUCTURAL INTEGRITY OF ALL EXISTING STRUCTURES TO REMAIN. CONTRACTOR TO PROVIDE TEMPORARY SHORING AS REQUIRED. 200.4 CONCRETE SLABS ON GRADE HAVE BEEN DESIGNED TO BEAR ON COMPACTED SUBGRADE SOILS OR PROPERLY COMPACTED FILL AS PER 200.1. 205. SITE NOTES 205.1 THE FOLLOWING SITE NOTES SHALL BE CONFIRMED BY A GEOTECHNICAL ENGINEER. 205.2 REMOVE ALL TOPSOIL, VEGETATION, ORGANIC AND DELETERIOUS MATERIAL STRIPPING DEPTHS ARE ANTICIPATED TO RANGE BETWEEN 0 INCHES AND 12 INCHES. SOME AREAS MAY REQUIRE STRIPPING DEEPER THAN 12 INCHES. 205.3 AFTER STRIPPING AND SITE CLEARING, COMPACT THE EXPOSED SOILS WITH A LIGHTWEIGHT WALK BEHIND SLED OR ROLLER. COMPACTION SHALL CONTINUE UNTIL A DENSITY OF AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D-1557) HAS BEEN OBTAINED TO A DEPTH OF AT LEAST 12 INCHES BELOW THE COMPACTED SURFACE. THE ROLLER COVERAGES SHALL BE DIVIDED EVENLY INTO TWO PERPENDICULAR DIRECTIONS. 205.4 STRUCTURAL FILL SHALL CONSIST OF AN INORGANIC, NON-PLASTIC, GRANULAR SOIL CONTAINING LESS THAN 10% MATERIAL PASSING THE NO. 200 MESH SIEVE. PLACE STRUCTURAL FILL IN LIFTS NOT EXCEEDING 6 INCHES IN LOOSE THICKNESS AND COMPACT EACH LIFT THOROUGHLY WITH A SLED OR ROLLER. COMPACTION SHALL BE CONTINUED UNTIL A DENSITY OF AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY IS OBTAINED IN EACH LIFT. 205.5 THE UPPER 12 INCHES OF ALL SANDY BEARING SOILS IN THE FOOTING EXCAVATION BOTTOM SHALL BE COMPACTED TO AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY. COMPACTION OR RE- COMPACTION OF SANDY BEARING SOILS SHALL BE DONE WITH A RELATIVELY LIGHTWEIGHT WALK BEHIND SLED OR ROLLER. WHEN USING A LIGHTWEIGHT COMPACTOR, INDIVIDUAL FILL LIFTS SHALL BE 6 INCHES OR LESS IN LOOSE THICKNESS. 205.6 TESTING: A MINIMUM OF ONE IN-PLACE DENSITY TEST PER 2000 SF (MINIMUM OF 1 PER LAYER) OF COMPACTED SURFACE AND AT LEAST ONE IN-PLACE DENSITY TEST FOR AT LEAST 50 PERCENT OF INDIVIDUAL SPREAD FOOTINGS AND EVERY 50 LINEAR FEET OF CONTINUOUS FOOTING. 205.7 FOR CONCRETE SLABS ON GRADE REMOVE ALL EXPOSED ORGANIC MATERIAL, RUBBLE AND DELETERIOUS MATERIAL. 205.8 COMPACT THE EXPOSED SOILS WITH A WALK-BEHIND VIBRATORY PLATE COMPACTOR UNTIL A DENSITY OF 95% OF THE MODIFIED PROCTOR IS OBTAINED AT LEAST 12 INCHES BELOW THE COMPACTED SURFACE. 210. SHALLOW FOUNDATIONS 210.1 SPREAD FOOTINGS HAVE BEEN DESIGNED TO BEAR ON UNDISTURBED SOILS OR PROPERLY COMPACTED FILL HAVING AN ALLOWABLE BEARING CAPACITY OF 2000 PSF, AS PER 200.1. 210.2 ELEVATIONS SHOWN ON THE DRAWINGS AT WHICH FOUNDATIONS ARE TO BEAR ARE APPROXIMATE. MATERIAL ON WHICH FOUNDATIONS ARE TO BEAR SHALL HAVE AT LEAST THE ABOVE NOTED CAPACITY. ALL EXTERIOR FOOTINGS SHALL BE A MINIMUM OF 1'-4" BELOW FINISHED GRADE. 210.3 THE OWNER/CONTRACTOR SHALL RETAIN THE SERVICES OF A PROFESSIONAL GEOTECHNICAL ENGINEER, SUBJECT TO THE APPROVAL OF THE ARCHITECT, TO INSPECT THE FOUNDATIONS, BEARING LEVELS, ETC., AND VERIFY THAT THE MATERIAL ON WHICH FOUNDATIONS BEAR HAS AT LEAST THE ABOVE NOTED CAPACITY AS PER 200.1. 300 REINFORCED CONCRETE 300.1 ALL REINFORCED CONCRETE WORK SHALL BE IN CONFORMANCE WITH THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318, LATEST EDITION) AND SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301, LATEST EDITION) OF THE AMERICAN CONCRETE INSTITUTE. 300.2 MINIMUM F'c REQUIRED AT 28 DAYS: a. FOUNDATIONS AND CONCRETE FILL . . MIN. f'c = 3000 PSI b. SLABS ON GRADE . . . . . . . MIN. f'c = 4000 PSI c. COLUMNS AND BEAMS . . . . . . MIN. f'c = 4000 PSI 300.3 MAXIMUM WATER CEMENT RATIO: a. FOUNDATIONS AND CONCRETE FILL . . . . . . 0.60 b. SLABS ON GRADE . . . . . . . . . . . 0.56 c. COLUMNS AND BEAMS. . . . . . . . . . . 0.56 300.4 ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE (144 PCF +) WITH ALL CEMENT CONFORMING TO ASTM C150, TYPE I. MAXIMUM AGGREGATE SIZE SHALL BE 1-1/2" FOR FOOTINGS AND 3/4" FOR WALLS AND SLABS, CONFORMING TO ASTM C33. 300.5 REINFORCEMENT a. DEFORMED BARS . . . . . . . ASTM A615, GRADE 60 b. WELDED WIRE MESH . . . . . . . . . ASTM A185 300.6 MINIMUM COVER FOR CAST-IN-PLACE CONCRETE REINF., UNLESS OTHERWISE SHOWN ON DRAWINGS, SHALL BE AS FOLLOWS: FOOTINGS & GRADE BEAMS ........ ...........................3" COLUMNS & PEDESTALS (OVER VERT. REINF.). ..................... 2" BEAMS (OVER MAIN REINF.) ........ ........................... 2" SLABS CAST AGAINST EARTH. ....... ....................... CENTERED 300.7 300.8 NO BACKFILLING AGAINST FOUNDATION WALLS SHALL BE PERMITTED UNTIL SUPPORTING STRUCTURAL ELEMENTS HAVE BEEN PLACED AND HAVE BECOME CAPABLE OF FURNISHING THE NECESSARY SUPPORT FOR THE WALLS. PROVIDE TEMPORARY SHORING WHERE REQUIRED. WHERE BACKFILL IS REQUIRED ON BOTH SIDES OF THE WALL, BACKFILL BOTH SIDES SIMULTANEOUSLY WITH A GRADE DIFFERENCE NOT TO EXCEED 2'-0" AT ANY TIME. CONTRACTOR SHALL USE EXTREME CAUTION DURING BACKFILULING TO PREVENT DAMAGE TO FOUNDATION WALLS. THE USE OF HEAVY EQUIPMENT FOR BACKFILLING IS NOT RECOMMENDED. 300.9 SPLICES IN REINFORCEMENT, WHERE PERMITTED, SHALL BE AS FOLLOWS: WELDED WIRE MESH . . . . .......................... . 8" ALL OTHERS . . . . . . . . . CLASS "B" TENSION, CASE "1" MINIMUM, UNLESS OTHERWISE NOTED CLASS "B" CASE "1" TENSION SPLICES IN INCHES, SHALL BE AS FOLLOWS: 3000 PSI 4000 PSI TOP BARS ALL OTHERS TOP BARS ALL OTHERS 3 10 28 22 24 19 i4 13 37 29 32 25 5 16 47 36 40 31 6 19 56 43 48 37 7 22 81 63 70 54 8 25 93 72 80 62 9 29 105 81 91 70 10 32 118 91 102 79 11 136 131 101 113 87 300.10 TOP BARS IN BEAMS SHALL TERMINATE IN A CLASS "B" TENSION SPLICE OR HOOK AT DISCONTINUOUS END. 300.11 PARALLEL REINFORCEMENT PLACED IN TWO OR MORE LAYERS SHALL HAVE A CLEAR DISTANCE BETWEEN LAYERS OF 1 INCH. UPPER LAYER BARS SHALL BE PLACED DIRECTLY ABOVE BARS IN THE BOTTOM LAYER. 300.12 ALL REINFORCING SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES DURING PLACEMENT OF CONCRETE. REINFORCING SUPPORTS FOR ALL EXPOSED CONCRETE SHALL BE GALVANIZED WITH PLASTIC COATED FEET. ALL WELDED WIRE MESH SHALL BE CHAIRED IN ACCORDANCE WITH THE 2001 FBC. 300.13 ALL TIES SHALL HAVE 135 DEGREE HOOKS. 300.14 PROVIDE 1/2" PRE-MOLDED EXPANSION MATERIAL WHERE SLAB ON GRADE IS POURED AROUND COLUMNS AND AGAINST WALLS UNLESS OTHERWISE SHOWN ON DRAWINGS. 300.15 CONSTRUCTION JOINTS FOR SLABS ON GRADE SHALL BE SPACED NO MORE THAN 16'-0" O.C. PANELS SHALL BE AS SQUARE AS POSSIBLE WITH A LENGTH TO WIDTH RATIO NOT TO EXCEED 1.5. 300.16 CONTRACTOR SHALL VERIFY DIMENSIONS AND LOCATIONS OF ALL SLOTS, PIPE SLEEVES, ETC., AS REQUIRED FOR MECHANICAL TRADES BEFORE CONCRETE IS PLACED. 300.17 PIPES OR CONDUITS PLACED IN SLABS SHALL NOT HAVE AN OUTSIDE DIAMETER LARGER THAN 1/3 THE SLAB THICKNESS AND SHALL NOT BE SPACED CLOSER THAN 3 DIAMETERS ON CENTERS. ALUMINUM CONDUITS SHALL NOT BE PLACED IN CONCRETE. NO CONDUITS SHALL BE PLACED IN SLAB WITHIN 12" OF COLUMN FACE OR FACE OF BEARING WALL. NO CONDUITS MAY BE PLACED IN EXTERIOR SLABS. 300.18 PRIOR TO PLACING CONCRETE, THE CONTRACTOR SHALL SUBMIT FOR REVIEW BY STRUCTURAL ENGINEER A CONCRETE POUR SCHEDULE SHOWING LOCATION OF ALL PROPOSED CONSTRUCTION JOINTS. 300.19 PRIOR TO CONCRETE PLACEMENT, THE CONTRACTOR SHALL SUBMIT A CONCRETE MIX DESIGN, PREPARED IN ACCORDANCE WITH THE SPECIFICATIONS, TO THE STRUCTURAL ENGINEER FOR REVIEW. 350 CONCRETE/MASONRY ANCHORS 350.1 ALL HEADED CONCRETE ANCHORS SHALL BE NELSON 3/4-INCH DIAMETER, 3/4-INCH S3L ANCHORS WITH FLUXED ENDS AS MANUFACTURED BY NELSON STUD WELDING COMPANY. UNLESS THE SIZE IS NOTED OTHERWISE ON THE STRUCTURAL DRAWINGS. 350.2 ALL HEADED CONCRETE ANCHORS SHALL BE MANUFACTURED FROM MATERIAL WHICH CONFORMS TO ASTM A108, GRADES 1015 THROUGH 1020. HEADED-STUD TYPE, COLD-FINISHED CARBON STEEL; AWS D1.1, TYPE B. 350.3 ALL WELDS SHALL BE MADE IN ACCORDANCE WITH STRUCTURAL WELDING CODE ANSI/AWS D1.1-86 OF THE AMERICAN WELDING SOCIETY AND THE RECOMMENDATIONS OF THE NELSON STUD WELDING COMPANY. 350.4 ALL ADHESIVE STUD ANCHORS SHALL BE "HILTI HIT-HY 150 ADHESIVE CONCRETE ANCHORS" AS MANUFACTURED BY HILTI FASTENING SYSTEMS, INC. (OR EQUAL). 350.5 ALL EXPANSION STUD ANCHORS SHALL BE "HILTI KWIK-BOLT II EXPANSION CONCRETE ANCHORS" AS MANUFACTURED BY HILTI FASTENING SYSTEMS. INC. (OR EQUAL). 350.6 THE "HAS ANCHOR ROD" SHALL CONFORM TO ASTM A36 STEEL, THE "HAS SUPER ANCHOR ROD" SHALL CONFORM TO ASTM A193 STEEL, THE "HAS STANDARD NUT" SHALL CONFORM TO ASTM A563, GRADE A, THE "HAS SUPER ANCHOR ROD NUT" SHALL CONFORM TO ASTM A 563, GRADE H. 350.7 THE "KWIK-BOLT II EXPANSION ANCHORS" STUD SHALL CONFORM TO ASTM A51 OR ASTM A108 STEEL AND THE NUT SHALL CONFORM TO ASTM A563, GRADE / 350.8 ALL EPOXY ADHESIVE ANCHORS FOR ANCHORING TO HOLLOW MASONRY SHALL BE "HILTI HIT-HY20 ADHESIVE ANCHORS" AS MANUFACTURED BY HILTI FASTENING SYSTEMS, INC. (OR EQUAL). 350.9 ALL EXPANSION ANCHORS FOR ANCHORING TO MASONRY SHALL BE "HILTI HLC SLEEVE ANCHORS" AS MANUFACTURED BY HILTI FASTENING SYSTEMS, INC. (OR EQUAL). 350.10 THE SPACING, MINIMUM EMBEDMENT, AND INSTALLATION OF THE ANCHORS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED PROCEDURES. 420 MASONRY 420.1 ALL MASONRY WORK SHALL BE IN CONFORMANCE WITH THE LATEST EDITION OF "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530) AND THE "SPECIFICATIONS FOR MASONRY STRUCTURES" (ACI 530.1) OF THE AMERICAN CONCRETE INSTITUTE. 420.2 ALL MASONRY WORK TO BE EXECUTED IN COLD WEATHER SHALL BE IN CONFORMANCE WITH THE RECOMMENDATIONS FOR COLD WEATHER CONSTRUCTION OF THE LATEST EDITION OF "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530) AND THE "SPECIFICATIONS FOR MASONRY STRUCTURES" (ACI 530.1) OF THE AMERICAN CONCRETE INSTITUTE WITH THE FOLLOWING ADDITION TO THE REQUIREMENTS OF ACI 530.1 SECTION 1.8-B: FOR ALL CONDITIONS WHEN TEMPERATURES FALL BELOW 40 DEGREES F, THE TEMPERATURE OF THE NEWLY LAID MASONRY OR NEWLY GROUTED MASONRY SHALL BE MAINTAINED ABOVE 32 DEGREES (F) FOR A MINIMUM OF 24 HOURS USING THE METHODS DESCRIBED IN ACI 530.1. 420.3 MORTAR SHALL CONFORM TO THE PROPORTION SPECIFICATION OF ASTM C270, TYPE M OR S. PROVIDE TYPE M MORTAR AT ALL HIGH STRENGTH MASONRY NOTED AS F'm = 2500 PSI OR GREATER. PROVIDE TYPE S MORTAR AT ALL STRUCTURAL MASONRY AND REINFORCED MASONRY UNLESS NOTED OTHERWISE. 420.4 GROUT .......... ........................... ASTM C476 a. F'c OF GROUT ...... ................... 3000 PSI MIN. b. SLUMP OF GROUT SHALL BE 8 TO 11 INCHES AS MEASURED ACCORDING TO ASTM C143. c. MAX. AGGREGATE SIZE SHALL BE 3/8" (AGGREGATE GRADED TO PRODUCE FINE GROUT IN CONFORMANCE WITH ASTM C476 AND C404). 420.5 LIMIT CEMENTITIOUS MATERIALS IN MORTAR TO: PORTLAND CEMENT CONFORMING TO ASTM C150 TYPE I; LIME CONFORMING TO ASTM C207; AND MORTAR CEMENT CONFORMING TO ASTM C1329. 420.6 CONCRETE BLOCK UNITS a. SOUD AND HOLLOW LOAD BEARING UNITS PER ASTM C90, TYPE N-Il, AS REQUIRED TO PROVIDE F'm AS NOTED BELOW. 420.7 MINIMUM 28-DAY ULTIMATE COMPRESSIVE STRENGTH OF MASONRY a. F'm ......... ............................. 1500 PSI SPLICES IN TOP REINFORCEMENT SHALL BE MADE AT MIDSPAN. SPLICES IN BOTTOM REINFORCEMENT SHALL BE OVER SUPPORTS UNLESS NOTED OTHERWISE. 420.8 HORIZONTAL JOINT REINFORCING FOR ALL EXTERIOR AND LOAD BEARING WALLS SHALL BE GALVANIZED LADDER TYPE DUR-O-WALL OR EQUAL AS APPROVED BY THE ENGINEER WITH 2-9 GAGE LONGITUDINAL WIRE AND 9 GAGE CROSS WIRE. SPACED AT 16 INCHES CENTER TO CENTER, UNLESS NOTED OTHERWISE. PROVIDE ADDITIONAL LAYERS OF JOINT REINFORCEMENT IN THE FIRST TWO COURSES ABOVE AND BELOW A MASONRY OPENING. PROVIDE LAP AS RECOMMENDED BY MANUFACTURER WITH A MINIMUM OF 6". DISCONTINUE JOINT REINFORCING AT CONTROL JOINTS. PROVIDE "L" SHAPE AND "T" SHAPE DUR-O-WALL AT ALL INTERSECTION CORNERS WITH 8" MINIMUM LAP. SEE TYPICAL DETAILS. 420.9 FULL BED AND HEAD JOINTS SHALL BE USED. 420.10 ALL MASONRY WALLS SHALL BE SECURELY BRACED UNTIL FLOOR OR ROOF SYSTEM HAS BEEN INSTALLED AND HAS BECOME CAPABLE OF STABILIZING THE WALLS. 420.11 REINFORCED MASONRY UNITS SHALL BE FILLED SOLID WITH 3000 PSI GROUT AT ALL CELLS CONTAINING REINFORCING AND WHERE SHOWN ON PLANS. GROUT ALL CELLS BELOW GRADE SOLID. 420.12 PROVIDE FINE GROUT PER ASTM C476 WHEN WIDTH OF GROUT SPACE IS LESS THAN 2". PROVIDE COARSE GROUT FOR GROUT SPACE WIDTHS 2" OR GREATER. PROVIDE FINE GROUT WHEN REINFORCING HAS LESS THAN 1/2" CLEARANCE. 420.13 PROVIDE CONTROL JOINTS IN MASONRY PER THE TYPICAL DETAILS. REFER TO ARCHITECTURAL DRAWINGS FOR CONTROL JOINT LOCATIONS. PROVIDE CONTROL JOINTS IN CONCRETE MASONRY BACKUP TO MATCH LOCATIONS IN MASONRY VENEER UNLESS OTHERWISE NOTED WHERE CONTROL JOINTS ARE NOT INDICATED ON THE ARCHITECTURAL DRAWINGS, CONTROL JOINTS SHALL BE LOCATED AT A MAXIMUM SPACING OF 24 FEET ON CENTER AND A MAXIMUM OF 10 FEET FROM CORNERS; AT MAJOR HEIGHT CHANGES; CHANGES IN WALL THICKNESS; AND AT WALL OPENINGS. THE CONTRACTOR SHALL SUBMIT THE PROPOSED CONTROL JOINT LAYOUT TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL. 420.14 PROVIDE CLEAN OUT AND INSPECTION HOLES AT BOTTOM OF MASONRY WALL IN ACCORDANCE WITH MASONRY CODE AT REINFORCING IF HIGH LIFT GROUTING (OVER 4 FEET HIGH) IS USED. 420.15 DEFORMED BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60. PROVIDE LAP SPLICES OF 48 BAR DIAMETERS MINIMUM. PROVIDE BAR SPACERS AS REQUIRED TO PROPERLY LOCATE REINFORCING. 420.16 MASONRY COURSING SHOWN IN SECTION IS APPROXIMATE. REFER TO PLANS AND ELEVATIONS FOR ACTUAL COURSING. COORDINATE ACTUAL COURSING REQUIREMENTS WITH ARCHITECTURAL DRAWINGS. 420.17 ALL ANCHOR BOLTS SHALL BE ASTM A307. 510 STRUCTURAL STEEL 510.1 ALL STRUCTURAL STEEL WORK SHALL BE IN ACCORDANCE WITH THE "LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" (1993 EDITION, AS REVISED) OF THE AISC. 510.2 GRADE OF STEEL a. STRUCTURAL SHAPES . . . . . . . ASTM A572, GRADE 50 b. STEEL TUBES (HSS SHAPES) . . . . . ASTM A500, GRADE B c. STEEL PIPE . . . . . . . . . . ASTM A500, GRADE B d. ANGLES AND PLATES . . . . . . . ASTM A36 510.3 GALVANIZED STRUCTURAL STEEL a. BOLTS, FASTENERS AND HARDWARE . . . . . ASTM A153 510.4 ALL BOLTS SHALL BE ASTM A325, 3/4-INCH DIAMETER, UNLESS NOTED OTHERWISE. WHERE NECESSARY DUE TO CONNECTION REQUIREMENTS PROVIDE BOLTS IN CONFORMANCE WITH ASTM A490. DO NOT MIX 0 GRADES OF BOLTS OF THE SAME DIAMETER ON THE PROJECT. 4. 510.5 ALL WELDING SHALL BE IN ACCORDANCE WITH THE STRUCTURAL WELDING CODE, AWS D1.1, LATEST EDITION, OF THE AMERICAN WELDING SOCIETY. ELECTRODES SHALL BE E7OXX FOR MANUAL ARC WELDING AND F7X-EXXX FOR SUBMERGED ARC WELDING. 510.6 ALL BEAM TO COLUMN CONNECTIONS SHALL BE DESIGNED FOR THE SUMMATION OF THE FOLLOWING LOADS: a. FOR ONE HALF THE UNIFORM LOAD CAPACITY OF THE MEMBER IN ACCORDANCE WITH AISC SPECIFICATIONS, BUT NOT LESS THAN 6 KIPS. b. A 10.0 KIP AXIAL FORCE (ACTING IN TENSION AND COMPRESSION). c. THE EFFECTS OF CONCENTRATED LOADS OCCURRING CLOSE TO THE ENDS OF THE BEAMS. 510.7 ALL NON-COMPOSITE BEAM END CONNECTIONS SHALL BE DESIGNED, UNLESS NOTED OTHERWISE, FOR AN END REACTION "R" EQUAL TO NOT LESS THAN ONE HALF THE UNIFORM LOAD CAPACITY OF THE MEMBER IN ACCORDANCE WITH AISC SPECIFICATIONS, BUT NOT LESS THAN 6 KIPS. THE EFFECTS OF CONCENTRATED LOADS OCCURRING CLOSE TO THE ENDS OF THE BEAMS SHALL BE CONSIDERED IN THE CONNECTION DESIGN. 510.8 CUTS, HOLES AND COPING, ETC. REQUIRED FOR OTHER TRADES SHALL BE SHOWN ON THE SHOP DRAWING AND MADE IN THE SHOP. CUTS OR BURNING OF HOLES IN STRUCTURAL STEEL IN THE FIELD WILL NOT BE PERMITTED. 510.9 ALTERNATE CONNECTION DETAILS MAY BE USED IF SUCH DETAILS ARE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL. HOWEVER, THE ENGINEER SHALL BE THE SOLE JUDGE OF ACCEPTANCE AND THE CONTRACTOR'S BID SHALL ANTICIPATE THE USE OF THOSE SPECIFIED DETAILS SHOWN ON THE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF SUCH ALTERNATE DETAILS WHICH HE PROPOSES. 510.10 ALL STRUCTURAL STEEL FRAMES SHALL BE SECURELY BRACED UNTIL ALL FLOOR SLABS, ROOF DECKS AND SHEAR WALLS HAVE BEEN INSTALLED AND BECOME CAPABLE OF STABILIZING THE FRAMES. 510.11 ALL STRUCTURAL STEEL WORK, EXCEPT PORTIONS OF MEMBERS TO BE WELDED, FIELD BOLTED OR FIREPROOFED, SHALL BE SHOP PAINTED WITH PAINT CONFORMING TO STEEL STRUCTURES PAINTING COUNCIL (SSPC) PAINT 25. APPLY PRIME PAINT ACCORDING TO SSPC PAINT SYSTEM GUIDE NO. 7.00. CLEAN STEEL FREE OF LOOSE SCALE, RUST, OIL AND GREASE. ADDITIONAL AREAS SHALL BE FiELD PAINTED AFTER WELDING. 510.12 BOLT AND WELD TESTING: a. ALL SHOP AND FIELD BOLTS SHALL BE TESTED PER AISC REQUIREMENTS. b. ALL WELDS SHOULD BE VISUALLY INSPECTED. c. TEN PERCENT OF ALL WELDS AT BEAM AND GIRDER SHEAR CONNECTIONS SHALL BE RANDOMLY INSPECTED BY MAGNETIC PARTICLE METHOD, COMPLYING WITH ASTM E109, PERFORMED ON ROOT PASS AND ON FINISHED WELD. d. ONE HUNDRED PERCENT OF FULL PENETRATION WELDS SHALL HAVE ULTRASONIC INSPECTION, COMPLYING WITH ASTM E164. e. ONE HUNDRED PERCENT OF WELDS IN BEAM AND COLUMN MOMENT CONNECTIONS SHALL HAVE ULTRASONIC INSPECTION, COMPLYING WITH ASTM E164. I |