![]() ![]() |
![]() |
UFDC Home | Search all Groups | World Studies | Federal Depository Libraries of Florida & the Caribbean | Vendor Digitized Files | Internet Archive | | Help |
Material Information
Subjects
Notes
Record Information
|
Full Text |
E i. 8. SoLA"k /f038 /i /LJ3
SOLAR/1038-79/04 Monthly Performance Report SADDLE HILL TRUST LOT 36 APRIL 1979 U.S. Department of Energy SNational Solar Heating and Cooling Demonstration Program National Solar Data Program 4270 I NOTICE This report was prepared as an account of work sponsored by the United States Government. Neither the United States nor the United States Department of Energy, nor any of their employees, nor any of their contractors, subcontractors, or their employees, make any warranty, express or implied, or assume any legal liability or responsibility for the accuracy, completeness or usefulness of any information, apparatus, product or process disclosed, or represents that its use would not infringe privately owned rights. MONTHLY PERFORMANCE REPORT SADDLE HILL TRUST LOT 36 APRIL 1979 I. SYSTEM DESCRIPTION Saddle Hill Trust Lot 36 is a single-family residence in Medway, Massachusetts. Solar energy is used for space heating the home and preheating domestic hot water (DHW). The system has an array of flat-plate collectors with a gross area of 315 square feet. The array faces south at an angle of 58 degrees to the horizontal. A 60 percent glycerol solution is the transfer medium that delivers solar energy from the collector array to storage; water is the transfer medium that delivers solar energy from storage to the space heating and hot water loads. Solar energy is stored in the basement in a 750-gallon storage tank. The tank is made of steel and lined with polyurethane. Preheated city water is supplied, on demand, to a conventional 80-gallon DHW tank. When solar energy is insufficient to satisfy the space heating load, an oil furnace provides auxiliary energy for space heating. Similarly, a conventional electric 80-gallon DHW heater provides auxiliary energy for water heating. The system, shown schematically in Figure 1, has three modes of solar operation. Mode 1 Collector-to-Storage: This mode activates when the collector tempera- ture is either more than 400F higher than storage temperature or higher than 1500F. Pump P1 is on. Solar energy transfer takes place through a heat exchanger located inside the storage tank. Mode 2 Storage-to-Space Heating: This mode activates when there is a demand for space heating, storage temperature is 700F or higher, and house temperature is lower than storage temperature. Pump P3 is on. Solar energy transfer takes place through a heat exchanger located inside the air duct. Mode 3 Storage-to-DHW Tank: This mode activates when storage water is 50F higher than water in the DHW tank. Pump P2 is on. Solar energy transfer takes place through a heat exchanger located inside the DHW heater. II. PERFORMANCE EVALUATION INTRODUCTION The site was occupied in April and the solar energy system operated continuously during the month. Solar energy satisfied 69 percent of the DHW requirements and 20 percent of the space heating requirements. The solar energy system provided an electrical energy savings of 2.1 million Btu and fossil fuel energy savings of 1.8 million Btu. 1 4270 1001 COLLECTOR PLANE TOTAL INSOLATION V T001 OUTDOOR TEMPERATURE V T600 INDOOR TEMPERATURE T150 W401 T452 T453 SPACE RETURN HEATING AIR T402 SUPPLY EP401 O T451 < T401 F400 T100 OIL FURNACE DOMESTIC HOT SW100 HOT WWATER SEP400 I T352 L DHW T351 HEATER T301 \ W301 t4 T302 EP100 5W400 COLD S T151 T450 WATER i- 40 1 L SUPPLY EP300 Figure 1. SADDLE HILL TRUST, LOT NO. 36,SOLAR ENERGY SYSTEM SCHEMATIC WEATHER CONDITIONS During the month, total incident solar energy on the collector array was 11.1 million Btu for a daily average of 1178 Btu per square foot. This was below the estimated average daily solar radiation for this geographical area during April of 1230 Btu per square foot for a south-facing plane with a tilt of 58 degrees to the horizontal. The average ambient temperature during April was 470F as compared with the long-term average for April of 490F. The number of heating degree-days for the month (based on a 650F reference) was 546, as compared with the long-term average of 492. THERMAL PERFORMANCE System During April the solar energy system performed somewhat poorer than expected. The expected performance was determined from a modified f-chart analysis using measured weather and subsystem loads as inputs. Solar energy collected was 4.3 million Btu versus an estimated 5.2 million Btu. Solar energy used by the system was estimated by assuming that all energy collected would be applied to the load. Actual solar energy used was 3.4 million Btu. System total solar fraction was 30 percent versus an estimated 59 percent. Collector The total incident solar radiation on the collector array for the month of April was 11.1 million Btu. During the period the collector loop was operating, the total insolation amounted to 8.6 million Btu. The total collected solar energy for the month of April was 4.3 million Btu, resulting in a collector array efficiency of 38 percent, based on total incident insola- tion. Solar energy delivered from the collector array to storage was 4.3 million Btu. There was no measured energy loss during transfer from the collector array to storage. Operating energy required by the collector loop was 0.098 million Btu. Storage Solar energy delivered to storage was 4.3 million Btu. There were 3.4 million Btu delivered from storage to the DHW and space heating subsystems. Energy loss from storage was 0.62 million Btu. This loss represented 14 percent of the energy delivered to storage. The storage efficiency was 86 percent: This is calculated as the ratio of the sum of the energy removed from storage and the change in stored energy, to the energy delivered to storage. The average storage temperature for the month was 1150F. DHW Load The DHW subsystem consumed 2.4 million Btu of solar energy and 1.0 million Btu of auxiliary electrical energy to satisfy a hot water load of 1.2 million Btu. The solar fraction of this load was 69 percent. Losses from the DHW subsystem were 2.2 million Btu. The DHW subsystem consumed a total of 0.17 million Btu of operating energy, resulting in an electrical energy savings of 2.2 million Btu. A daily average of 53 gallons of DHW were consumed at an average temperature of 138F delivered from the tank. Space Heating Load The space heating subsystem consumed 1.1 million Btu of solar energy and 7.0 million Btu of auxiliary fossil fuel energy to satisfy a space heating load of 5.3 million Btu. The solar fraction of this load was 3 4270 20 percent. The space heating subsystem consumed a total of 1.8 million Btu of operating energy, resulting in an electrical energy expense of 0.020 million Btu. OBSERVATIONS The DHW loop was on continuously throughout the month. This was a prime contributor to the 2.2 million Btu energy loss in the DHW system. ENERGY SAVINGS The solar energy system provided a net electrical energy savings of 2.1 million Btu and a fossil fuel energy savings of 1.8 million Btu. The DHW subsystem provided an electrical energy savings of 2.2 million Btu, while the space heating subsystem provided a fossil fuel energy savings of 1.8 million Btu and incurred an electrical energy expense of 0.020 million Btu. III. ACTION STATUS The system designer is investigating DHW subsystem operation. 4 4270 SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM MONTHLY REPORT SITE SUMMARY SITE: SADDLE HILL TRUST LOT 36, REPORT PERIOD: APRIL,1979 MEDWAY, MA SOLAR/1024-79/04 SITE/SYSTEM DESCRIPTION: THE SADDLE HILL TRUST LOT #36 SOLAR ENERGY SYSTEM PROVIDES SPACE HEATING AND HOT WATER FOR A SINGLE FAMILY RESIDENCE. THE COLLECTOR IS A 14 PANEL LIQUID COLLECTOR* STORAGE IS A 750 GALLON WATER TANK LOCATED IN THE BASEMENT. AUXILIARY HEATING IS PROVIDED BY A 140,000 BTU/HR OIL FURNACE AND AUXILIARY HOT WATER BY A 14.676 BTU/HR ELECTRIC DOMESTIC HOT WATER HEATER. GENERAL SITE DATA: INCIDENT SOLAR ENERGY COLLECTED SOLAR ENERGY AVERAGE AMBIENT TEMPERATURE AVERAGE BUILDING TEMPERATURE ECSS SOLAR CONVERSION EFFICIENCY ECSS OPERATING ENERGY TOTAL SYSTEM OPERATING ENERGY TOTAL ENERGY CONSUMED 11.135 35350 4.269 13551 47 70 0.31 0.098 2.035 14.277 MILLION BTU BTU/SQ.FT. MILLION BTU 9TU/SQ*FT. DEGREES F DEGREES F MILLION BTU MILLION BTU MILLION BTU SUBSYSTEM SUMMARY: LOAD SOLAR FRACTION SOLAR ENERGY USED OPERATING ENERGY AUX. THERMAL ENERGY AUX. ELECTRIC FUEL AUX. FOSSIL FUEL ELECTRICAL SAVINGS FOSSIL SAVINGS HOT WATER 1.246 69 2.357 0.171 1.001 1.001 N.A. 2.185 N.A. HEATING 5.256 20 1 072 1.766 4.184 N.A. 6.973 -0.020 1.787 COOLING N.A. N.A. N.A. N.A. N. A N.A. N.A. N.A. N.A. SYSTEM TOTAL 6.497 MILLION STU 30 PERCENT 3.429 MILLION BTU 2.0,35 MILLION PTU 5.184 MILLION BTU 1.001 MILLION BTU 6.973 MILLION BTU 2.067 MILLION BTU 1.787 MILLION BTU SYSTEM PERFORMANCE FACTOR: 0.380 * DENOTES UNAVAILABLE DATA & DENOTES NULL DATA NeA. DENOTES NOT APPLICABLE DATA REFERENCE: USER'S GUIDE TO THE MONTHLY PERFORMANCE REPORT OF THE NATIONAL SCLAR DATA PROGRAM,FEBRUARY 28,1978, SOLAR/0004-78/18 SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM MONTHLY REPORT SITE SUMMARY SITE: SADDLE HILL TRUST LOT 36, REPORT PERIOD: APRIL,1979 MEDWAY, MA SOLAR/1024-79/04 SITE/SYSTEM DESCRIPTION: THE SADDLE HILL TRUST LOT #36 SOLAR ENERGY SYSTEM PROVIDES SPACE HEATING AND HOT WATER FOR A SINGLE FAMILY RESIDENCE. THE COLLECTOR IS A 14 PANEL LIQUID COLLECTOR. STORAGE IS A 750 GALLON WATER TANK LOCATED IN THE BASEMENT. AUXILIARY HEATING IS PROVIDED BY A 140.000 BTU/HR OIL FURNACE AND AUXILIARY HOT WATER BY A 14,676 BTU/HR ELECTRIC DOMESTIC HOT WATER HEATER. GENERAL SITE DATA: INCIDENT SOLAR ENERGY 11.748 COLLECTED SOLAR ENERGY AVERAGE AMBIENT TEMPERATURE AVERAGE BUILDING TEMPERATURE ECSS SOLAR CONVERSION EFFICIENCY ECSS OPERATING ENERGY TOTAL SYSTEM OPERATING ENERGY TOTAL ENERGY CONSUMED SUBSYSTEM SUMMARY: LOAD SOLAR FRACTION SOLAR ENERGY USED OPERATING ENERGY AUX. THERMAL ENG AUX. ELECTRIC FUEL AUX. FOSSIL FUEL ELECTRICAL SAVINGS FOSSIL SAVINGS HOT WATER 1.315 69 2.486 0.181 1.056 1.056 N.A. 2.306 N.A. HEATING 5.545 20 1.131 1.863 4.414 N.A. 7.356 -0.022 1.885 COOLING N.A. N.A. N.A. N.A. N. A N.A. N. A N.A. N.A. GIGA JOULES 401430 KJ/SQ.M. 4.503 GIGA JOULES 153885 KJ/SQ.M. 8 DEGREES C 21 DEGREES C 0.31 0.103 GIGA JOULES 2.146 GIGA JOULES 15.062 GIGA JOULES SYSTEM TOTAL 6.854 GIGA JOULES 30 PERCENT 3.617 GIGA JOULES 2.146 GIGA JOULES 5.470 GIGA JOULES 1.056 GIGA JOULES 7.356 GIGA JOULES 2.181 GIGA JOULES 1.885 GIGA JOULES SYSTEM PERFORMANCE FACTOR: 0.380 * DENOTES UNAVAILABLE DATA @ DENOTES NULL DATA N.A. DENOTES NOT APPLICABLE DATA REFERENCE: USER'S GUIDE TO THE MONTHLY PERFORMANCE REPORT OF THE NATIONAL SOLAR DATA PROGRAMFEBRUARY 28,1978, SOLAR/0004-78/18 SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM MONTHLY REPORT ENERGY COLLECTION AND STORAGE SUBSYSTEM (ECSS) SOLAR/1024-79/04 SITE: SADDLE HILL TRUST LOT 36, MEDWAY, MA REPORT PERIOD: APRIL,1979 DAY OF MONTH INCIDENT SOLAR ENERGY MILLION BTU 0.111 0.033 0.097 0.299 0.100 0.404 0.343 0.722 0.041 0.263 0.717 0.612 0.551 0.074 0.148 0.110 0.343 0.505 0.406 0 597 0.667 0.393 0.632 0.642 0.389 0.373 0.419 0.234 0.541 ----------I 11.135 0.371 0001 --I---------- AMBIENT TEMP DEG-F 44 38 41 40 40 38 35 38 34 38 44 48 43 38 41 41 43 46 44 47 50 52 63 60 62 63 * 64 59 65 - 47 N113 -----1- ENERGY TO LOADS MILLION STU 0.038 0.042 0.030 0.056 0.042 0.053 0.058 0.217 0.104 0.064 0.152 0.226 0.311 0.131 0.054 0.036 0.046 0.122 0 154 0 153 0.212 0.247 0.133 0*131 0.115 0.117 0.105 0.064 0.098 3.429 0.114 ----~-------- ECSS ENERGY REJECTED MILLION BTU N 0 T A P P L I C A B L E AUX THERMAL TO ECSS MILLION BTU N 0 T A P P L I C A B L E N.A. N.A. ECSS OPERATING ENERGY MILLION BTU 0.001 0.000 0.001 0.004 0.000 0.004 0.003 0.005 0.000 0.003 0.006 0.006 0.004 0.000 0.000 0.000 0.004 0.006 0.004 0.006 0.005 0.004 0.006 0.005 0.003 0.003 0.005 0.002 0.006 0.098 0.003 0102 0102 * DENOTES UNAVAILABLE DATA. 8 DENOTES NULL DATA. N.A. DENOTES NOT APPLICABLE DATA. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SUM AVG NBS ID ECSS SOLAR CONVERSION EFFICIENCY 0.348 1.274 0.313 0.187 0.415 0.130 0.169 0.301 2.542 0.245 0.212 0i369 0.565 1.765 0.366 0 330 0.134 0.242 0.379 0 257 0.318 0.630 0.211 0.205 0.296 0.314 0.252 0.275 0.181 0.308 N111 N.A. N.A. SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM MONTHLY REPORT COLLECTOR ARRAY PERFORMANCE SITE: SADDLE HILL TRUST LOT 36, MEDWAY, MA REPORT PERIOD: APRIL,1979 SOLAR/1024-79/04 ---------- ----------- INCIDENT SOLAR ENERGY MILLION BTU DAY OF MONTH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 29 30 SUM AVG NBSID I OPERATIONAL INCIDENT ENERGY MILLION BTU 0.036 0.000 0e025 0.243 0.011 0.320 0.207 0.647 0.000 0.150 0.651 0.542 0.493 0.000 0.009 0.000 0.254 0.432 0.322 0.522 0.585 0.274 00592 0.533 00257 0.216 0.360 0.113 0.470 ------------- 8.550 0.285 * DENOTES UNAVAILABLE DATA. 8 DENOTES NULL DATA. NsAe DENOTES NOT APPLICABLE DATA. ~----------1 0.111 0.033 0.097 0.299 0.100 0.404 0.343 0.722 0.041 0.263 0.717 0.612 0.551 0.074 0.148 0.110 0.343 0.505 0.406 0.597 0.667 0.393 0.632 00642 0.389 0.373 0.419 0.234 0.541 11.135 I----------- 0.371 Q001 -----(-------------- COLLECTED SOLAR ENERGY MILLION BTU I---------- 0.016 0.000 0.011 0 124 0 009 0.167 0.093 0.330 0.000 0.056 0.343 0.267 0.251 0.000 0.004 0.000 0.138 0.204 0.158 0.259 0.307 0*127 0.310 0.269 0. 120 0.098 0.169 0.067 0.231 4.269 ~------------1 0.142 -100- DAYTIME AMBIENT TEMP DEG F /----------1 45 38 45 49 42 44 38 42 34 42 51 57 53 40 45 46 52 53 54 59 67 65 71 74 73 73 65 * 52 ----------( COLLECTOR ARRAY EFFICIENCY -------------I 0.142 0.000 0.111 0.415 0.086 00413 0.270 0.456 0.000 0.212 0 479 0.436 0.456 0.000 0.028 0.000 0.404 0.403 0.388 0.434 0.461 0.324 0.492 0.419 0.309 0.263 0.403 0 285 0.427 -----------| ----_------ - 0.383 N100 SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM MONTHLY REPORT STORAGE PERFORMANCE SITE: SADDLE HILL TRUST LOT 36, REPORT PERIOD: APRIL,1979 MEDWAY. MA SOLAR/I 024-79/04 DAY OF MONTH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SUM AVG NBS ID ENERGY TO STORAGE MILLION BTU 0.017 0 000 0.013 0.124 -0.001 0.172 0.088 0.325 0.000 0.060 0.343 0.271 0.253 0.000 0.005 0.000 0.144 0.213 0.164 0.266 0.311 0.132 0.320 0.274 0.115 0.095 0.178 0.054 0.244 4.325 -~--------- 0.144 Q200 -~--------- ENERGY FROM STORAGE MILLION BTU 0.038 0.042 0.030 0.056 0.042 0.053 0.058 0.217 0.104 0.064 0.152 0.226 0.311 0.131 0,054 0. 036 0.046 0.122 0.154 0.153 0.212 0,247 0.133 0.131 0.115 0.117 0.105 0.064 0.098 3.429 ------------I 0.114 0201 I---------- CHANGE IN STORED ENERGY MILLION BTU -0.022 -0.033 -0.015 0.053 -0.028 0.097 0.012 0.079 -0.089 -0.010 0.147 0. 032 -0.073 -0.109 -0.044 -0.032 0.071 0.064 -0.000 0.087 0.062 -0.108 0.174 0.070 -0.030 -0 043 -0.134 0.040 -0.030 0.087 0.275 0.009 0202 STORAGE EFFICIENCY STORAGE AVERAGE TEMP DEG F 93 89 85 89 90 95 105 120 109 103 119 126 125 109 98 92 96 110 114 122 130 124 137 148 151 144 131 130 137 115 0,856 N108 * DENOTES UNAVAILABLE DATA. 8 DENOTES NULL DATA. NAA. DENOTES NOT APPLICABLE DATA. 1 006 1.000 1.218 0.880 -17.524 0 866 0.798 0.911 1 000 0.893 0.872 0.949 0.941 1.000 2.018 1.000 0.814 0.873 0.935 0.000 0.882 1 056 0.960 0.737 0.747 0 783 0.817 0.631 0.755 SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM MONTHLY REPORT HOT WATER SUBSYSTEM SITE: SADDLE HILL TRUST LOT 36, MEDWAY, MA REPORT PERIOD: APRIL,1979 SOLAR/1024-79/04 ---- I DAY OF MON. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SUM AVG NBS HOT WATER LOAD MILLION BTU 0.0261 0.043 0.018 0,040 0.043' 0.050 0 045 0.0561 0.037 0.0381 0 032 0 0301 0.023 0.058 0.052 0.043 0.0401 0.022 0.0351 0 057 0.025 0 086 0.042 0.052 0.042 0.0491 0.0541 0.016 0.0491 1.246 0.042 0302 ________ |- -------I----------- SOLAR FR.OF LOAD PER CENT 47 42 35 41 44 43 53 75 68 581 74 82 76 67 54 50 48 58 68 69 81 85 92 96 99 100 891 83 90 69 N300 SOLAR ENERGY USED MILLION BTU 0.038 0.042 0.030 0.0561 0.042 0.053 0.058 0.122 0.062 0.064 0.105 0.107 0.0731 0.070 0.0541 0 036 0.0461 0.060 0.096 0.104 0.072' 0.1241 0.133 0.1311 0,115 0.117 0.105 0.064 0.098 ---------- i 2.357 ------- 1 0.079 Q300 0300 OPER ENERGY MILLION BTU 0 006 0 006 0.005 0.006 0.006 0 0061 0.006 0.006 0.006 0.006 0.006 0.006 0.005 0.006 0.006 0.006 0.005; 0.006 0.006 0.006 0. 005 0.006 0.006 0.006 0.006 0.006 0.006 0.006 0.006 0.171 0.006 Q303 AUX THERMAL USED MILLION BTU 0.047 0.061 0.055 0.071 0.055 0.060 0.043 0.032 0. 039' 0.046 0.034 0.023 0.023 0.049 0.048 0.044 0.044 0 029 0.044 0.041 0.006 0.034 0.003 0.004 0.000 0.000 0.013 0.015 0.004 1.001 0.033 0301 Q301 AUX ELECT FUEL MILLION BTU 0.047 0.061 0.055 0.071 0.055 0 060 0.043 0.032 0.0391 046 0.0341 0.023 0.023 0.049 0.048 0.044 0.044 0.029 0 044 0.0411 0.006 0.034 0.003 0.004 0.000 0.000 0.013 0.015 0.004 --------- I 1.001 0.033 Q305 AUX FOSSIL FUEL MILLION BTU N 0 T A P Pi L I C A B L' El --- -_______ I N.A. N.A. 0306 -------- I ELECT ENERGY SAVINGS MILLION BTU 0.033 0.0361 0:025 0.050 0.036 0 047 0.0521 0.117 0.056 0.059 0.099 0.101 0.0671 0.064 0.048 0.0311 0.040 0.0551 0.090 0.098 0.067 0.118 0.127 0.125 0.1091 0.111 *I 0.100 0.059 0.092 2.185 _______ | 0.073 0311 * DENOTES UNAVAILABLE DATA. @ DENOTES NULL DATA. N.A. DENOTES NOT APPLICABLE DATA. --------I FOSSIL ENERGY SAVINGS MILLION BTU N 0 T A P P L Il C Al B| L El N. A. N.A. 0313 ---- I SUP. WAT. TEMP DEG F ---- i 59' 50 511 49 501 49 51 52 49 53 48 521 53 51 47 46 55 53 48 49 541 49 53 54 53 55 55 51 55 I 521 N305 ---- I HOT WAT. TEMP DEG F 139 143 1391 142 1421 143 142 139 140 136 139 139' 128 134 137 143 130 134 139 141 1361 140 1331 135 144] 138 130 141 136 -1 138] N307 HOT WATER USED GAL 35 52 24 52 53 61 56 74 46 51 39 39 29 75 65 57 55 28 45 72 32 109 54 64 50 64 73 21 65 1596 53 N308 SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM MONTHLY REPORT SPACE HEATING SUBSYSTEM SITE: SADDLE HILL TRUST LOT 36. REPORT PERIOD: APRIL,1979 MEDWAY, MA SOLAR/1024-79/04 DAY OF M3N. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SUM AVG NBS SPACE HEATING LOAD MILLION BTU 0.178 0.334 0.234 0.164 0.199 0.272 0.384 0.245 0.361 0.267 0.196 0.147 0.239 0.315 0.231 0.235 0.197 0.203 0.204 0. 166 0.185 0.124 0.000 0.000 0.000 0.000 0.000 0.000 0.000 5.256 0.175 0402 SOLAR FR. OF LOAD PCT 0 0 0 0 0 0 0 39! 12 0 24 81 100 19 0 0 0 31 28' 30 75 100 0 0' 0 0 0 0l -I 20 N400 SOLAR ENERGY USED MILLION BTU 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.043 0.000 0.047i 0.119 0.239 0.061' 0.000 0.000 0.000 0.062 0.058 0.049 0.140 0 124 0.000 0.0001 0.000 0.000 0.0000 0.000 0.000 ------"-- 1 1.072 -- ------ | 0.036 0400 0400 OPER ENERGY MILLION BTU 0. 043 0.082 0.058 0.042 0.048 0.065 0 090 0 097 0.109 0. 065 0.0641 0. 092 0.1701 0.111 0 0561 0.056 0.051 0.0791 0. C79 0.057 0. 106 0 0881 0.000 0 000 0.000 0.000 I* 0.000 0.0001 0 000 --------I 1.766 0.059 0403- 0403 --,------ i AUX ELECT FUEL MILLION BTU N 0 T A P P L I C A B L E AUX THERMAL USED MILLION BTU 0 178 0.334 0.234 0 164 0 199 0.272 0.384 0.150 0.318 0 267 0 148 0.028 0 000 0.253 0.231 0.235 0.197 0.141 0.146 0.117 0.046 0.000 0.000 0.000 0 000 0.000 0.000 0.000 0.000 4.184 0.139 0401 ----I AUX FOSSIL FUEL MILLION BTU 0.297 0.556 0.391 0.274 0.3311 0,454 0.6411 0.251 0 5301 0.446 0 247 0.047 0.000 0.4221 0.384 0:392 0.328 0.234 0.244 0 1951 0.076 0.000 0.0001 0.000 0.0000 0.000 0.000 00000 --------- 1 6.973 0.2320 0410 ELECT ENERGY SAVINGS MILLION BTU 0.000 0,000 0.000 0.000 0.0000 0.000 0.000 -0.002 -0.0011 0.000 -0.001 -0.002 -0 005 -0.0011 0.000 0.000 0.000 -0.001 -0 001 -0.001 -0.003 -0.002 0.000 0.000 00000 0,000 0.0000 0.000 0,000; -0.0201 -0.001 Q415 FOSSIL ENERGY SAVINGS MILLION BTU 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.158 0.071 0.000 0.078 0.198 0.398 0 102 0.000 0 000 0.000 0 103 0 097 0 082 0. 27- 0.206 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1 .787 0.060 0417 BLDG AMB TEMP TEMP DEG. F 68 70 711 67 68 67 67 68 69 70 70 70 70 701 70 70! 70 701 701 69 701 72 711 70 71 72 * 72 72 72 70 N406 DEG. 44 38 41 40 40 38 35 38 34 38 44 48 43 38 41 41 43 46 44 47 C0 52 63 60 62 63 * 64 59 65 47 N113 * DENOTES UNAVAILABLE DATA. 8 DENOTES NULL DATA. N.A. DENOTES NOT APPLICABLE DATA. NoAo N.A. N.A. SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM MONTHLY REPORT SPACE COOLING SUBSYSTEM SITE: SADDLE HILL TRUST LOT 36, REPORT PERIOD: APRIL,1979 MEDWAY, MA SOLAR/1024-79/04 DAY OF MON. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SUM AVG NBS SPACE COOLING LOAD MILLION BTU N' 0 T A P P LI I C A B L El N.A. ----------- N.A. Q502 ---------I SOLAR FR. OF LOAD PCT N 0 T Al Pi Pi L I C A B L E -I N.A. N500 ----I N.A. N.A. 0500 SOLAR ENERGY USED MILLION BTU N 0 T A P P L I C A B LI E OPER ENERGY MILLION BTU N 01 T A P P L I C A B Ll E N.A. ~-------- -IeA N.A. Q503 AUX THERMAL USED MILLION BTU N 01 Ol T A P P L I C Al B L E N.A. N.A. Q501 AUX ELECT FUEL MILLION BTU N 0 T A P P L I C A B L El N. A. N.A. -1 AUX FOSSIL FUEL MILLION BTU N O T A P P A B L E N.A. N.A. 0508 N.A. N.A. 0512 ELECT ENERGY SAVINGS MILLION BTU N O T A P P L I C A B L E N.A. N.A. 0514 * DENOTES UNAVAILABLE DATA. @ DENOTES NULL DATA. N.A. DENOTES NOT APPLICABLE DATA. FOSSIL ENERGY SAVINGS MILLION BTU N 0 T A P P L I C A B L E BLDG DRY BULB TEMP F 68 70 711 67 68 67 67 F8 69 70 70 701 70 70 70 70 70 70 70 69 70 72 71 70 71 72 72 72 72 72 70 N406 AMB TEMP DEG F 44 38 41 40 40 38 35 38 34 38 44 48 43 38 41 41 43 46 44 47 50 52 63 60 62 63 * 64 59 65 47 N113 SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM MONTHLY REPORT ENVIRONMENTAL SUMMARY SITE: SADDLE HILL TRUST LOT 36. MEDWAY, MA REPORT PERIOD: APRIL,1979 DAY TOTAL DIFFUSE AMBIENT OF INSOLATION INSOLATION TEMPERATURE MONTH BTU/SQ.FT BTU/SQ.FT DEG F 1 351 N 44 2 105 C 38 3 308 T 41 4 950 40 5 318 A 40 6 1283 P 38 7 1090 P 35 8 2293 L 38 9 130 I 34 10 836 C 38 11 2275 A 44 12 1943 B 48 13 1748 L 43 14 236 E 38 15 468 41 16 350 41 17 1088 43 18 1604 46 19 1289 44 20 1894 47 21 2116 50 22 1246 52 23 2005 63 24 2037 60 S25 1236 62 26 1183 63 27 * 28 1329 64 29 743 59 30 1718 65 1 ~---- W1-*--1 11 L------ > ---------*--- ----- S ---- ^w ---- --_ -----B-l*l M ***W M W*--- 4-- M SSUM 35350 .A. 0 _------- ---------- ---------_ -___________ AVG 1178 NA. 47 NBS ID 0001 N113 9 ~------_ ---------- ---------,*-. ------.----_ DENOTES UNAVAILABLE DATA. 8 DENOTES NULL DATA. N.A. DENOTES NOT APPLICABLE DATA. SOLAR/I 024-79/04 DAYTIME AMBIENT TEMP DEG F 45 38 45 49 42 44 38 42 34 42 51 57 53 40 45 46 52 53 54 59 67 65 * 71 74 73 * 73 65 * - 52 I---------- --------- RELATIVE HUMIDITY PERCENT ---------~--1 N T A P P L I C A B L E N-A. WIND DIRECTION DEGREES N 0 T A D P L I C A B L E /--------------- I ---- -----| N.A. N115 ------------I WIND SPEED M.P.H. N 0 T A P 0 L I C A B L E N.A. N114 UNIVERSITY OF FLORIDA 11111i lllll11111 llll III 111 3 1262 09052 6236 |
Full Text |
xml version 1.0 encoding UTF-8
REPORT xmlns http:www.fcla.edudlsmddaitss xmlns:xsi http:www.w3.org2001XMLSchema-instance xsi:schemaLocation http:www.fcla.edudlsmddaitssdaitssReport.xsd INGEST IEID EV7FG7Q7J_L9F7OP INGEST_TIME 2014-04-09T21:34:46Z PACKAGE AA00013812_00002 AGREEMENT_INFO ACCOUNT UF PROJECT UFDC FILES |