Group Title: Historic St. Augustine: B7-L7 deBurgo-Pellicer
Title: Specifications for job DOS 6110
ALL VOLUMES CITATION MAP IT! THUMBNAILS PAGE IMAGE ZOOMABLE
Full Citation
STANDARD VIEW MARC VIEW
Permanent Link: http://ufdc.ufl.edu/UF00091331/00071
 Material Information
Title: Specifications for job DOS 6110
Series Title: Historic St. Augustine: B7-L7 deBurgo-Pellicer
Physical Description: Interpretive outline
Language: English
 Subjects
Subject: Saint Augustine (Fla.)
53 Saint George Street (Saint Augustine, Fla.)
de Burgo-Pellicer House (Saint Augustine, Fla.)
Spatial Coverage: North America -- United States of America -- Florida -- Saint Johns -- Saint Augustine -- 53 Saint George Street
Coordinates: 29.896143 x -81.31318
 Record Information
Bibliographic ID: UF00091331
Volume ID: VID00071
Source Institution: University of Florida
Holding Location: University of Florida
Rights Management: All rights reserved by the source institution.
Resource Identifier: B7-L7

Full Text



SPECIFICATIONS FOR JOB DOS 6110


SECTION 7C PAGE 1
ROOFING & SHINGLES

7C-1 GENERAL

A. WORK IN OTHER SECTIONS
Roof sheathing
Flashing of ducts and pipes thru roof.

B. EXTENT OF WORK
Complete installation of a Class "B" label cedar shingle roof using materials
below

C. SUBMITTALS
Submit manufacturers' literature describing all procedures to be used in
applying the Class "B" system.

D. GUARANTEE
Provide 2 year written guarantee on wo rkmanship and materials.

E. ROOFING SUBCONTRACTOR
Approved by manufacturer of roofing materials and the Architect.

F. PACKAGES & LABELS
Deliver materials in sealed packages, original manufacturers' labels thereon.
Do not remove labels or open packages until Architect inspects and approves.


7C-2 MATERIALS

A. MATERIALS AND WORKMANSHIP
Conform to Standard Specification of "Red Cedar Shingle and Hand Split Shake
Bureau, Seattle, Washington, and U. L. requirements.

B. INSULATION

(1) Material:
1" thick "Celo-therm" non-combustible perlite insulation as manufactured by
Celotex Corporation, or approved.

(2) Application:
Apply over roof sheathing as recommended by manufacturer.

C. UNDERLAYMENTS

(1) Steel Foil:
0. 002 in. thick x 27 in. wide "Koppers" polyethelene coated st eel foil.

(2) Roofing felt:
U. L. Labeled Type 15 (15 lb. ) plain asphalt asbestos felt.

(3) Application:
Apply steel foil underlayment over roof insulation; attach and position joints
as recnarzmaide by-Tnar-tfacturer.
Foil to cover entire roof.
Apply Labeled 15-lb. felt over steel foil and nail with tin tags.
Felt to cover entire roof surface.
Use only enough nails to hold underlayment until shingles are in place.


ROOFING & SHINGLES


PAGE 1


SECTION 7C






SECTION 7 C Page 2
ROOFING & SHINGLES




7C-2 Materials

D. SPECIFICATIONS Roofing, Shingles, Flashing

(1) Flashing:
16oz. copper. Provide flashing at ridge; intersection of dormers and main
roof; intersection of chimney and main roof.

E. SHINGLES CLASS C.

(1) Size and type:
No. 1, Koppers, Blue label, red cedar, machine split, 18" x 5/2" x 45".

(2) Application:
Lay in horizontal courses, straight butt lines, 5 1/2" to weather.

F. NAILS
Hot dipped galvanized, size and type as recommended by manufacturer.


ROOFING & SHINGLES


PAGE 2


END OF SECTION 7C




University of Florida Home Page
© 2004 - 2010 University of Florida George A. Smathers Libraries.
All rights reserved.

Acceptable Use, Copyright, and Disclaimer Statement