• TABLE OF CONTENTS
HIDE
 Front Cover
 Main
 Back Cover














Group Title: Historic St. Augustine: De Mesa Sanchez House, Block 7 Lot 6
Title: Tuttle and Bailey
ALL VOLUMES CITATION MAP IT! THUMBNAILS PAGE IMAGE ZOOMABLE
Full Citation
STANDARD VIEW MARC VIEW
Permanent Link: http://ufdc.ufl.edu/UF00091263/00154
 Material Information
Title: Tuttle and Bailey
Series Title: Historic St. Augustine: De Mesa Sanchez House, Block 7 Lot 6
Physical Description: Maintenance record
Language: English
Publication Date: 1979
 Subjects
Subject: Saint Augustine (Fla.)
43 Saint George Street (Saint Augustine, Fla.)
de Mesa-Sanchez House (Saint Augustine, Fla.)
Spatial Coverage: North America -- United States of America -- Florida -- Saint Johns -- Saint Augustine -- 43 Saint George Street
Coordinates: 29.896429 x -81.313225
 Record Information
Bibliographic ID: UF00091263
Volume ID: VID00154
Source Institution: University of Florida
Holding Location: University of Florida
Rights Management: All rights reserved by the source institution.
Resource Identifier: B7-L6

Table of Contents
    Front Cover
        Page 1
    Main
        Page 2
        Page 3
        Page 4
        Page 5
        Page 6
        Page 7
        Page 8
        Page 9
        Page 10
        Page 11
        Page 12
        Page 13
        Page 14
        Page 15
    Back Cover
        Page 16
Full Text



















1r









S TUTTLE & BAILEY
DIVISION OF ALLIED THERMAL CORPORATION








RESTORATION OF THE DEMESA-SANCHEZ HOUSE
FOR THE ST. AUGUSTINE HISTORIC PRESERVATION bOARD
Job Name ...JS.T....AU.GJUSI TINX ... FLO )IDA ...................................................................................................................

Contractor AUNTLEY BROTHERS INC. XECH.DIV.; PALATKA FL. (VERB FK)
Contractor ............. .. ..................... .. .......... ........ ..................... ...................... ...............................................................

Architect .....HEPARD ASOC. AT.ES; JACSONVILLE LOIDA

Engineer ..EVANS & HAMMOND; JACKSONVILLE, FLORIDA

Representative bLURNE--GARNiTET'T & ASSOCIATES ,INC.; JACKSONVILLE, FL.
R epresentati e .c ...- .-..- ..E- .-. --.-.........-....-..T-....-.... .......... ..... -.T _.. -. -._ .--. -. _. -. ..-. -- .---... -.- .................. ...........

10-16-79

SCHEDULE SYMBOLS


MATERIAL
AL Aluminum
XAL Extruded Aluminum
GALV Galvanized
STL- Steel


HIGH PRESSURE EQUIPMENT
DD Double Duct
SD Single Duct
L Left Hand fHot or Single Duct
R Right Hand IUnlet Location
DA- Direct Acting
RA Reverse Acting


TUTTLE & BAILEY STANDARD FINISHES
G1 Gray Enamel* Duct Accessories,
W1 White Enamel* Diffusers, Panels, T-CT, NT-CT.
SA Satin Anodized Steel Grilles, Registers,
Imperialine, EL Linear.
Extruded Aluminum Grilles, Registers, Diffusers.
Aluminum Duct Accessories mill finish.
*This finish it a durable baked enamel finish in itself. It may be repainted in the field
however, see FIELD REPAINTING section of catalog Architectural Paint Finish Chart.

OTHER ARCHITECTURAL COLOR FINISHES WHICH ARE AVAILABLE-SPECIFY BY SYMBOL

LACQUER FINISHES


Symbol Color
81 Dark Bronze
B2 Medium Bronze
J1 Flat Black


Symbol Color
W White*
Al Bright Aluminum


Symbol Color
D1 Matches Duranodic #311 E
D2 Matches Duranodic #312 E
D3 Matches Duranodic #313 E


*Specify by number from catalog Architectural Paint Finish Chart.








NOTE
The furnishing of all items listed on the attached schedules is subject to any government restrictions applicable thereto and
contingent upon our ability to procure the necessary raw materials required for the fabrication of same.


R-75


Printed in U.S.A.




U~ U T Y L. = Qi6 W A% I L. M
DIVISION OF AW1ED 77iERMAL CORPORA rlON
GRILLE AND DIFFUSER SCHEDULE

g.Ng CWM PLAN
OOCA1ION QUAN. ST"LE LST90 StZZ cm N o. MATINISHI RE MARK


A H DIST'RIBUTION TUTTTLE & MIL Y








Ceiling 4 b404-BO 36I x 4 Slot :LS 6400 Y L- S With

I 6403-BO 3611 x 3 -.'lot- 170 11 Vol Dp r

It 1 u403-BO 3611 x 3 Slot tbo & Ir atterr

I401-BO 36#" x 3 Slot 1135 Control

2 6403-IJO 30'" x 3 Slot 120

1 .4- 36" x 3 0lot 130 H



FLOOR jUPPIY REGISTUI _




Floor 43uU 30 .f4 X 1U 4-3ULisU X,' L CLrn heir-forcec

I, j For Floor'
2 _____ 24 x 4 1i0 0 LX. e.

I24 x4 1u ( 10

# 24 Y.x4 170 r H

I 1. I24 x 6 2) "0Q















.;On Re-itcratio n thDe emeca-Sanchez House; St.AugustAineTKFl. 10 OATZ
wWC By zs


Af
SHEET NUMBER
I or 3
or


3 SCHLULI NUMSeR


POINTWIOrN US.A R67


rrrvi~tunr




.J W. L_ A- I L-- =-- T
DIVISION OF AUIED THERMAL CORPORATION
S GRILLE AND DIFFUSER SCHEDULE
mII 0 AO A. Y
IN I.OCATION QUAN. STMI LLS UST SIZE CFM DNO. MATlt. PIN1S REMARK


AIR Dn STRIBUTION TT & BAILEYX----(C-t'-)


W____ALL RETI REGISTERS



Sidewall 2 A77D 12 x 2 A77 .---IAL.

S_1 __24 x 6 "

S___1 36 6 t ".
t 2 24 x 8 "



V99T VOLU1 DAU XFLLS


r An.h Dut 1 No.7S 16 x 12 No.7S STL G1T With

a" n i 18 x 16 N Side
.... ..Screw
1 12 x 8 O Operatcre




FLEXII Lk CUCT Thermofin. Xtc.



48 ft.ModelA-2<0 i sulated 8" Dia, X 8' long UL labeled flexi le cuct.

Double ply aliminim flexible duct with double wrap 3/4" fibe glass

insulation witt viryl sheath.





j BY DATE
keHtoration of the Demesa-Sanchez House; St.AugustineFl. WWG 10/16/
5 N


(1T


SHEIT NUMBER
2 or 3
SCHEDULE NUMBER
JS-
PRINTID IN U.S.A. "67


REMSIONS
I 1 "2
______!V a w ~ ^ .. ^ i L -I


I A l


3





DIVISION OF ALLIED THERMAL CORPORA TION
GRILLE AND DIFFUSER SCHEDULE

M LOCATIONN QUAN. STYLE OUSTED SI5Z CPr M. Ow. MATT. NI REMARM
*N0. NrOM.


SPIN N FI TINGS MET, iL MANUFACTURI 4G CO._



Ten have MS-1-1 ap n in fitting s 38 dia. for use with uheet metal duct work.






CEILING EXiAUST FAN ROAN MANUFACTUItNG CO.




One Model 35 insulated cab net ceiling ex aust fan n ted

76 CFM at .25 S 1050 RPM 1 70 HP, llbV-1- i- .b5 oiie__

complete wi h MHdel No, 57 polid state spe d control.
c

































.JO1B Y ATS
Restoration of the Demesa-Sanchez House; St.Augustine,Fl. WWG 10-16-
S-- --9......" .----


SI4ET NUM3maR
3 oa 3


f SCEDUUE NUMBER

is-


I -1 2






STATE OF fLORIDA


HISTORIC ST. AUGUSTINE PRESERVATION BOARD

V. --- P.O. BOX 1987
ST. AUGUSTINE, FL 32084
(904) 824-3356
DEPARTMENT OF STATE
George Firestone
Secretary of State


October 23, 1979








Huntley Bros., Inc.
P. O. Drawer 1319
1211 Madison Street
Palatka, FL 32077


Attention: Julie Van Cleave


This is to acknowledge receipt of six (6) sets of
submittals on plumbing, fans, and air conditioning for the
DeMesa-Sanchez House.


These have been forwarded to the architect, Shepard
and Associates this date together with our comments.


Sincerely,


Robert H.
Director,


Steinbach
Research and Development


RHS: jh


BOARD OF TRUSTEES


Mwhal Y'. k;annon
Chairman
'aluhcth M. ITowV2s


Mary Call Collins
Vice-chairman
Lawrence L. Lewis, Jr.


Maj. Gen. Henry McMillan (Ret.)
Secretary-Treasurer
John D. Bailey


William R. Adams
Director






STATE OF FLORIDA


HISTORIC ST. AUGUSTINE PRESERVATION BOARD

P.O. BOX 1987
ST. AUGUSTINE, FL 82084
(904) 824-3856
DEPARTMENT OF STATE
George Firestone
Secretary of State


William R. Adams
Director


November 15, 1979


Huntley Brothers Mechanical Division
1211 Madison Street
Palatka, Florida 32077

Gentlemen:

Please find enclosed two (2) copies
fans, equipment, diffusers and grilles.


of plumbing literature; AC,


Also enclosed is a Letter of Transmittal from the architect.
Under "Remarks" you will note "Floor registers are required to have
a duranodic finish to match flooring." Do you have available a color
chart from which we may make a selection?



Sincerely,




Robert H. Steinbach
Director, Research &
Development


RHS:jh
Enc:


BOARD OF TRUSTEES


Michael V. Gannon
Chairman
Elizabeth M. Towers


Mary Call Collins
Vice-chairman
Lawrence L. Lewis, Jr.


Mqj. Gen. Henry McMillan (Ret.)
Secretary-Toaurer
John D. Bailey





WITH FULL PATTERN CONTROL


OVERALL I OPENING SIZE-LISTED SIZE + 1546--
DUCT= LISTED LENGTH

i _--- ,_CORE--LISTED LENGTH- _/2 ___




I -- "-- ,_ ".... _. ."-: --. -._ -. ,T-- --. -


DUCT WIDTH -! /

DA

DAMPER


ADJUSTABLE PATTERN
DEFLECTOR


DAMPER AND
DEFLECTOR
SPECIFY.
64XX-BO


OUAN. SLOT
OF DUCT OVERALL DESIG-
SLOTS WIDTH WIDTH NATION

I :1 2 236 2 3 01

2 2 3m 1 35/8 02
3 4 /a 5 6 j /5 a 03
4 6 a 2 6 /2 04

5 7 7 '/ 7 6 05

6 a' 9 3/g 9 06

7 i 10 16 10 '16 07

8 I I 12 I 12 P 4 08

9 13 13 16 13 16 09

10 14 I 10
to 1' 1 !/s IS !/a 10


EQUALIZING P<
DAMPER ONLY DEFL
SPECIFY
63XXX-B0
Y MOUNTING FRAME
DESIGNATION NONE)
MARGIN DESIGNATION


PATTERN
ECTOR ONLY
SPECIFY
62XX-BO


NOTES;
* EXTRUDED ALUMINUM CONSTRUCTION
* MAX.ONE PIECE LENGTH -72"LISTED LENGTH
MIN. LENGTH-12"
* SECTIONS KEYED FOR PROPER ALIGNMENT

CONTRACTOR TO FRAME OPENING TO
INSURE STRAIGHT LINE INSTALLATION



1\ 0'; ,
'i / I1 MIN. *
4f f 'e MAX.

CEILING LINE '
DETAIL OF HEMMED EDGE OF DUCT S I
HEM OF DUCT SEALS SPACE
BETWEEN DUCT OPENING
AND DIFFUSER.


NO DEFLECTOR
OR DAMPER
SPECIFY
B6XX-BO


FEATURES
FULL IO1 PATTERN ADJUSTMENT


I-]-


1-I


IL


UNIQUE PATTERN CONTROL ALLOWS COMPLETE
ADJUSTMENT WITH CONSTANT DISCHARGE
VELOCITY AND STATIC PRESSURE NC NEED
TO REBALANCE AFTER CHANGING PATTERN-
ADJUSTS FROM FACE OF DIFFUSER SELF
LOCATING FOR HORIZONTAL PATTERNS

SEPARATE BALANCING DAMPER GIVES POSITIVE
VOLUME CONTROL WITHOUT AFFECTING AIR
PATTERN- ADJUSTS FROM FACE OF DIFFUSER

IMPERIALINE QUALITY THROUGHOUT
APPEARANCE PERFORMANCE -INSTALLATION
DIMENSIONS SHOWN CONTAIN EXPANSION
TOLERANCES BASED ON A TEMPERATURE
RISE OF 40 DEGREES F ABOVE THE
AMBIENT TEMPERATURE AT WHICH THE
MATERIAL IS FABRICATED.


S'DRAWN BY PLATE NO.
TUTTLE & BAILEY IMPERIALINE 6000 DIFFUSER 3/4. SLOT SERIES
STYLE "B MARGIN
DIVISION OF ALLIED THERMAL CORPORATION WITHOUT MOUNTING FRAME DATE 6000 -BO
n\ X- NuTAIN, CONNcIMIraT MIwA, flORro 5-15-77
fOMT 11, ONTARIO, CANADA LOKrIN, lLOIu

PIlNT&D IN U. S. A.


II
.r -- CC


6000



















TYPE 0 MARGIN


LISTED SIZE
LISTED SIZE-I (T







L LISTED OSIE T-:I-- ,
8 (TYP)

TYPE 0 MARGIN
FACE BARS ONLY 4100-00
WITH CONTROL GRID 4200-00


TYPE 0 MARGIN
WITH DAMPER ONLY 4300-00
WITH DAMPER A CONTROL GRID 4400-00

Ng 9 DAMPER FURNISHED ON LISTED WIDTH OF 22, 3" 3-
ONLY.


TYPE 0 MARGIN
WITH DAMPER ONLY
WITH DAMPER & CONTROL GRID


4300-00
4400-00


N-7 DAMPER FURNISHED ON LISTED WIDTHS OF 4& OVER.
- LISTED LENGTH
- LISTED LENGTH -
----L ~l Lu ,--- I
B-



TYPE 0 MARGIN
WITH MOUNTING BRACKET


TYPE G MARGIN


LISTED SIZE + ) I
16 1 1 1

I I






SDUCT SIZE=
LISTED SIZE + V4 (TYR)
TYPE G MARGIN
FACE BARS ONLY 4100- GO
WITH CONTROL GRID 4200-60


ONLY.


TYPE G MARGIN
WITH DAMPER ONLY
WITH DAMPER & CONTROL GRID


4300-GO
4400-GO


OPTIONAL FACE BARS
1/2 INCH CENTERS


56 2 33


III III ff
4100- 4101- 4115- 4130-

NOTES;
* EXTRUDED ALUMINUM CONSTRUCTION.
* G MARGIN HAS REMOVABLE CORE HELD SECURELY IN
PLACE BY CORE HOLDING RETAINERS.
SIZE LIMITATIONS- ONE PIECE:
LENGTH X WIDTH
C MARGIN- MIN. 4 X I I
MAX. 72 Y 36
0 MARGIN MIN. 6 X 2 /_
MAX. 72 X 36
LENGTHS OVER 72 INCHES FURNISHED AS 2 OR MORE
PIECES.
NOTE: G MARGIN SHIPPED LOOSE AND MUST BE
SUITABLY FRAMED TO DIMENSIONS SHOWN
ABOVE BY INSTALLING CONTRACTOR.
WIDTH CAN BE FURNISHED ONLY IN tj INCH INCREMENTS
DIMENSIONS SHOWN CONTAIN EXPANSION TOLERANCES
BASED ON A TEMPERATURE RISE OF 40 DEGREES F.
ABOVE THE AMBIENT TEMPERATURE AT WHICH
THE MATERIAL IS FABRICATED.


AVAILABLE ON ALL T
'


TUTTLE & BAILEY EXTRUDED ALUMINUM
4000 SERIES
DIVISION OF ALLIED THERMAL CORPORATION IMPERIALINE GRILLE
NMW bIIIAIN, CONNE IKT MIAMI, nLORA TYRE G AND 0 MARGINS
FORT IUr, ONTARIO, CANADA LOKERE, BIRUM


URAWIv DI


DATE
7-7-76


4001


PRINTED IN U. A. A.


I


nn~rrl ov arlrm~rl


I
















A70 SERIES
HORIZ. FACE BARS


A80 SERIES
VERT. FACE BARS


np


NOTES:
* BARS ON 3/4" CENTERS.
* SCREW HOLES STD. AS SHOWN UNLESS OTHERWISE SPECIFIED.
* MATERIAL: EXTRUDED ALUMINUM.
*MAX. ONE PIECE SIZE (MIN. SIZE 4W X 3H)
A70, A700. A77 & A770 72W x 48H
A80 A800, A88 & A880 48W X 72H


--I
DUCT SIZE
LISTED SIZE



J


A80D GRILLE


A77 REGISTER A88 REGISTER A77 D REGISTER
SHOWN) (SHOWN)
EXTRUDED ALUMINUM
TUTTLE II BAILEY RETURN GRILLES & REGISTERS
T DIVISION OF ALLID THURMAL CORPORATImO FIXED BARS
& m- NIIora MN, CMCmmr WIAL MuA a
S2J1OT .0L o T AuraI CANADA M, mMM4 uiM
PrINlTE IN U. L A.


A88D REGISTER


DRAWN
RR
DATI
5-1 --


LISTED
SIZE, 1I
4


A70 GRILLE
(SHOWN)


-I
DUCT SIZE
LISTED SIZE


A80 GRILLE


-.i




NOTES:
* STEEL CONSTRUCTION
* AVAILABLE WITH HORIZ. OR VERT. BLADES
.HORIZ: SPECIFY 8S -MIN. 3 x 4 MAX. 36 x 36
VERT :SPECIFY 7S-MIN. 4<3 MAX. 36 '36
* DAMPERS AVAILABLE IN I INCH INCREMENTS



_________


7S


U_


NOMINAL CAMPER SIZE
5,10,14,18,22,26,30 & 34 2
5,9,13,17,21,25,29 & 33 3

4,8,12,16,20.24,28,32 & 36 3
711,15,19.23,27,31 & 35 3
UNINSULATED DUCT ONLY


8S


LISTED
SIZE
5/64







X 4- -
SOPERATOR CLOCKWISE TO
OPEN (I DIA. MIN. HOLE
IN DUCT)
FACE VIEW
(7S SHOWN)

DUCT COLLAR




BRACKET 27/32



2 4




LISTED SIZE -

LISTED SIZE


8-32 2 LONG SCREW
CBY OTHERS) FIELD
INSTALLED USING
"LOCTITE" TO RETAIN
IN OPERATOR
INSULATED DUCT
APPLICATION


SIDE VIEW


TUTTLE & BAILEY
DIVISION OF ALLIID THERMAL CORPORATION
NaN SWIaN, CONNICtiCU MIAMI, frODA
FOT NUI, ONTANO, CANADA toKBM%, SIUUM


NO. 7S AND 8S DAMPER
SIDE SCREWDRIVER OPERATOR


PRINTED IN U. S. A.











MODEL ULTRA 100 AND 200

APPROXIMATE APPROXIMATE
WEIGHTS PER FOOT BENDING RADIUS
DUCT INSU- INSU-
INNER BARE LATED BARE LATED
DIA. DUCT DUCT DUCT DUCT

3" .123 .269 1%" 2'/1"
4" .161 .332 2" 3"
5" .199 .403 2/" 3W"
*3" .164 .310 1/" 2%"
*4" .215 .386 2" 3"
"5" .266 .470 2!." 3'i"
*6" .238 .466 3" 4"
*7" .276 .536 3%" 4'"
*8" .314 .598 4" 5"
'9" .352 .664 4%" 5%"
*10" .391 .729 5" 6%"
*12" .590 .992 6" 8"
*14" .686 1.138 7" 9"
16" .782 1.292 8" 10%"
18" .878 1.439 99" 11%"
20" .973 1.586 10" 13"
22" 1.069 1.735 11" 14"
24" 1.165 1.884 16"


*U/L LISTED. Air Duct Material Class
Each length of duct is so labeled.
Conforms to NFPA 90A and NFPA 90B


1 per U/L 181.


P~~ ''R r-.
.-s
s~~.( :.i..i
:h-
1
3


USE IT FOR ALL OF YOUR AIR
CONDITIONING HEATING -
VENTILATION SYSTEMS.


Write for Prices and Sample

CONNECTOR
Duct is available with one crimped end or male and/or female
connector per 8' length. Please specify when odering.


MODEL ULTRA 100
UNINSULATED DUCT


Ultra 100 is a semi-rigid, corrugated, easily bent metal
duct that can be formed by hand into curves and small
radius elbows.


Standard Ultra 100 Duct is fabricated in 8! lengths with an extra 2 inches of factory crimp on one end for tight, permanent,
male/female field connections. (Other lengths available on request.) In sizes 3" through 24" dia., ducts are spiral formed out
of 3003 bright reflective finished aluminum alloy, with 300 strength angles between ribs, mechanically locked together with a
continuous knurled leak-proof "Acme" lock.

Ultra 100 aluminum flexible duct is listed with the Underwriters' Laboratories, Inc. under U/L Guide FFGT, File MH9298,
Class I Air Duct Materials. and FEZU File MH9497, Class I Air Duct Connectors, and meets all requirements of U/L 181 and
complies with NFPA 90A and NFPA 90B. Since aluminum is not combustible it requires no fire rating.


MODEL ULTRA 200----INSULATED DUCT

Ultra 200 is the insulated line of semi-rigid corrugated, easily bent, aluminum metal duct that can be formed by hand into curves
and small radius elbows.

The inner core is our Ultra 100 Duct wrapped with two complete layers of 3/4" thick .75 Ibs. density fiberglass, covered with a
tough, 3 mil thick seamless vinyl tube, resisting the passage of moisture to 0.2 perms, and an overall "c" factor rating of 0.23
BTU's per hour, per square foot, per degree fahrenheit (F).

Ultra 200 insulated aluminum flexible duct is listed with Underwriters' Laboratories, Inc. under U/L Guide FFGT, File MH
9298, Class I Air Duct Materials, meets all the requirements of U/L 181 and complies with NFPA 90A and NFPA 90B. Using
the U/L listed Type "B" joint treatment Ultra 200 has a fire hazard classification rating with a flame spread not exceeding 25
and a smoke development not exceeding 50.

Ultra 200 insulated aluminum flexible duct is a high or low pressure duct, rated at 12 inches water gauge for positive and negative
working pressure for sizes 2" through 14" diameters. For diameters of 16" through 24", the duct is rated at 8 inches water
gauge for positive pressures, 8 inches water gauge for negative pressures.


~
~ .Ir







Spin-In & Twis-Lock

S'fittings


GENERAL DESCRIPTION
The Spin-In ard Twis-Lock is an air
positive finding, installed as a complete
unit it is engineered for making round
take off connections on any type of fi-
berglass duct board material or metal
duct. By nature of design, it insures
positive and fast installation substan-.
tially lowering labor costs and eliminat-
ing the need for tape, pins or screws.
TECHNICAL DATA
Fittings are constructed of galvanized
steel, securely riveted throughout.
Dampers are counter weighted and
positive locking. They are available in
sizes 4" thru 16" to standard pipe size
tolerances.


4 4













Fibit.qlass k, A
ApplLation Appi itior)


INSTALLATION PROCEDURE
1. Press spin-in fitting against duct.
Scribe outline of fitting on duct.
2. Using the appropriate tool, cut a round
hole approximately one-eighth larger
than the scribed line.
3. Cut a slot one inch deep so the start-
ing edge of spin-in will engage duct.
4. Insert starting edge into slot, turn the
entire fitting clockwise making certain
the fitting is held perpendicular to the
duct material and pressed firmly
against it.
5. Twist the fitting clockwise two com-
plete turns to insure it is properly seated.
6. Seal outer ring of fitting where it con-
tacts duct with mastic, in system that
exceed 0.5 inches w.g. internal
pressure.


Sr) O- L


U.. .** /* /


r,


/ '' ''' ,lr~ ~.;
c~
~' ,`~f











the fresh air people

LO-SONE VENTILATORS


Model 315 90 CFM
Model 317 130 CFM


Model 301 270 CFM Vertical
260 CFM Horizontal
Model 313 310 CFM
Model 319 190 CFM


FEATURES
0 Discharges horizontally or vertical-
ly to 31/4 x 10" duct. Damper
built-in.
0 Adjustable mounting brackets for
fast, easy installation.
0 Sound-deadening insulation in
housing.
0 Motor-fan assembly plugs in.
0 Rubber torsion mountings isolate
motor vibration noises.
0 Motor drives squirrel cage blower
at moderate speed to assure effec-
tive ventilation at minimum sound
levels.
Model 315 1050 RPM motor drives
51/4" (diam.) 3" blower wheel.
Model 317 1550 RPM motor drives
51/4" (diam.) 3" blower wheel.
Model 319 1050 RPM motor drives
two 51/4" (diam.) blower wheels.
0 Attractive anodized aluminum
grille on Models 301, 313, 319.
SHandsome satin-finish aluminum
grille on Models 315-317.
SBlower assembly can be easily in-
stalled or removed without tools.
SSpecifically designed to meet the
demand for quiet ventilation.
SRugged construction All-steel
housing.
SU.L. Listed, guaranteed 1 year.
SAir delivery certified by HVI.


FAN PERFORMANCE
Performance Ratings*
Wt. CFM at Varied Static Pressure
Model Ea. RPM AMPS H.P. 0 .1 .125 .250 .375 .5 Sones
301 17 1550 1.2 1/35 302 274 266 230 192 124 5.0
313 21 1550 2.4 1/15 340 310 302 256 218 180 5.0
315 14 1050 0.6 1/70 107 93 86 76 59 10 1.5
317 14 1550 0.8 1/50 147 134 131 112 92 56 3.0
319 21 1050 1.8 1/40 232 199 192 158 92 0 3.0

*Air delivery tests made in accordance with A.M.C.A. Bulletin 210 and Home Ventilating Institute Standard Test Code. Sound tests also conducted
at Texas Engineering Experiment Station are in accordance with Home Ventilating Institute's Sound Code.


L


II I


q;:::~


*MUMI*NGIKdlRm








LO-SONE DIMENSIONS


MODEL 319


FAN CAPACITY CUBIC FEET PER MINUTE


SUBMITTAL DISTRIBUTION



Project



Architect



Engineer



Contractor



Submitted by


CONTROL SWITCHES


59A 68


~.j*>*


No. 54A Solid State Infinite Speed Control.
Designed especially for Motordor Wall fans but can also be
used on all Broan fans and blowers. Installs in single-gang
box. Infinite speed control, rotary type switch withl positive
On/Off action. For use with shaded pole of permanent split
capacitor motors with ratings up to 5 amps. Brushed gold
color wall plate. Includes radio noise suppressor. 120V.,
60 cycle.
No. 57A Solid State Infinite Speed Control.
Features rotary dial movement for unlimited selection of air
speeds and sound levels. Full wove solid state, printed board
circuitry. Includes built-in radio noise suppressor. 118 v., 3
amp. capacity. Brushed gold color wall plate. For following
Broan models: 300, 312, 315, 317, 319, 461, 465, 466, 471,
475, 476, 477, 478, 479, 491, 496, 497, 499, 662, 668,
669, 670, 671, 675, 676.
No. 59A 60 Minute Time Control.
Provides timed control of heating or ventilation. Operates


for any set period up to 60 minutes, or continuously. Fits
single-gang 23/4 inch box.
No. 63 60 Minute Time Control with Toggle Switch.
Same as No. 59A except has two-gang switch plate. Toggle
switch included. Recommended for Broan models 162 & 164.
No. 61 15 Minute Time Control.
Fifteen minute timer control for heaters or ventilators. Oper-
ates from set period of up to 15 minutes. Fits single-gang
2%/4 inch box.
No. 66 Heater-Fan-Light Control.
Three independent circuits. Attractive brushed gold color wall
plate. For Models: 655 and 695. 12 v., 60 cycle, 15 amp.
circuit. Single gang.
No. 68 Dual Control.
Two independent circuits. Handsome brushed gold color wall
plate. 120 v., 60 cycle, 15 amp. circuit. For Models: 656,
657, 658, 678, 696, 162, 164. Single gang.


HVI CERTIFIED AIR DELIVERY
Air delivery ratings for all Broan ventilators are certified by the Home Ventilating Institute, based on independent tests made by the Texas
Engineering Experiment Station at Texas A & M University, and are rated on air movement performance in terms of cubic feet per minute
(CFM). Dupted Fans and Hoods are rated at 0.1" static pressure. Direct Discharge Wall Fans 0.03".


BROAN MFG. CO., INC.
the freshairpeople HARTFORD, WISCONSIN 53027