Title: St. Augustine assessment report
CITATION PDF VIEWER THUMBNAILS PAGE IMAGE ZOOMABLE
Full Citation
STANDARD VIEW MARC VIEW
Permanent Link: http://ufdc.ufl.edu/UF00090053/00001
 Material Information
Title: St. Augustine assessment report
Physical Description: Book
Language: English
Creator: Facilities Planning & Construction, Physical Plant Division, University of Florida
Publisher: Facilities Planning & Construction, Physical Plant Division, University of Florida
Place of Publication: Gainesville, Fla.
 Record Information
Bibliographic ID: UF00090053
Volume ID: VID00001
Source Institution: University of Florida
Holding Location: University of Florida
Rights Management: All rights reserved by the source institution and holding location.

Downloads

This item has the following downloads:

StAugReport ( PDF )


Table of Contents
    Front Cover
        Front Cover
    Introduction
        Page 1
    Table of Contents
        Page 2
    Building summary and budget estimate
        Page 3
    Building assessments
        Page 4
        Page 5
        Page 6
        Page 7
        Page 8
        Page 9
        Page 10
        Page 11
        Page 12
        Page 13
        Page 14
        Page 15
        Page 16
        Page 17
        Page 18
        Page 19
        Page 20
        Page 21
        Page 22
        Page 23
        Page 24
        Page 25
        Page 26
        Page 27
        Page 28
        Page 29
        Page 30
        Page 31
        Page 32
        Page 33
        Page 34
        Page 35
        Page 36
        Page 37
        Page 38
        Page 39
        Page 40
        Page 41
        Page 42
        Page 43
        Page 44
        Page 45
        Page 46
        Page 47
        Page 48
        Page 49
        Page 50
        Page 51
    Strategic business units
        Page 52
    ADA review
        Page A-1
        Page A-2
        Page A-3
        Page A-4
        Page A-5
        Page A-6
        Page A-7
        Page A-8
        Page A-9
        Page A-10
        Page A-11
        Page A-12
        Page A-13
        Page A-14
        Page A-15
        Page A-16
        Page A-17
        Page A-18
        Page A-19
        Page A-20
        Page A-21
        Page A-22
        Page A-23
Full Text













St.Augustine
Assessment Report

Prepared By:
Facilities Planning & Construction
Physical Plant Division
Environmental Health & Safety

July 2007
UF UNIVERSITY of
UF FLORIDA


I 1










Introduction


This document is intended to be a general assessment of 34 State-owned buildings in the City of St.
Augustine that are potentially being turned over to the University of Florida for initial rehabilitation and
future operations and maintenance. A team of University professionals, including representatives from
the Division of Facilities, Planning & Construction, Physical Plant, and Environmental Health & Safety,
spent over 300 hours evaluating structures, finishes, utilities infrastructure, life and fire safety, and ADA
accessibility with an eye toward assembling initial costs necessary to bring the condition of these
structures up to current codes and standards and to allow continued maintenance to begin under the
University's physical plant maintenance standards.

Each category of assessment, enumerated in the "component" column, was valued from 0, meaning not
surveyed, through 1, meaning no work necessary, to 5, indicating that complete replacement of that
component is necessary. Costs associated with these assessments are the best estimates of those
professionals conducting the surveys and are not intended to be actual construction prices. These
numbers include "soft costs" associated with managing the projects such as design, permitting,
inspections, contingencies, etc.


Proposed Historic Area Master Plan

The University of Florida proposes a partnership with the City of St. Augustine and local host
government to develop a master plan for the historic St. Augustine. The master plan will identify the
original town plan, significant buildings and sites, pedestrian and circulation, traffic, parking, wayfinding
through the historic area.


Funding Request: $500,000






St.Augustine Facility Assessment Report


Table of Contents


Section I-Building Summary and Budget Estimate

Section 2-GIS Location Map

Section 3-Building Assessments

Section 4-Financial Chart

Section 5-ADA Review


St. Augustine Facility Assessment Report July 2007 Page 2


St. Augustine Facility Assessment Report July 2007


Page 2









Building Summary and Budget Estimate
MINOR MAJOR
BLDG NAME ADDRESS GSF YR REHABILITATION $/SQ FT REHABILITATION $/SQ FT
3900 GOVERNMENT HOUSE 48 KING STREET 25,947 1710 $ 14,271,000 $ 550
3901 DE MESA SANCHEZ HOUSE 49 ST. GEORGE STREET 4,068 1760 $ 25,000 $ 6
3902 ARRIVAS HOUSE 46 ST. GEORGE STREET 4,041 1961 $ 885,000 $ 219
3903 PAREDES DODGE HOUSE 54 ST. GEORGE STREET 1,392 1808 $ 1,325,000 $ 952
3904 PAREDES DODGE OUTBUILDING 54 1/2 ST. GEORGE STREET 231 1808
3905 GALLEGOS HOUSE 21 ST. GEORGE STREET 905 1963 $ 198,000 $ 219
3906 RIBERA HOUSE 22 ST. GEORGE STREET 2,168 1964 $ 271,000 $ 125
3907 RIBERA KITCHEN 22 ST. GEORGE STREET 480 1964 $ 85,500 $ 178
3908 TRIAY HOUSE 29 ST. GEORGE STREET 690 1964 $ 106,875 $ 155
3909 GOMEZ HOUSE 27 ST. GEORGE STREET 314 1964 $ 57,750 $ 184
3910 CERVEAU HOUSE 26 CUNA STREET 3,059 1885 $ 1,682,000 $ 550
3911 HAAS HOUSE 28 CUNA STREET 2,337 1850 $ 511,000 $ 219
3912 PESO DE BURGO / PELLICER HOUSE 53 ST. GEORGE STREET 682 1976 $ 340,750 $ 499
3913 PESO DE BURGO N OUTBUILDING 53 ST. GEORGE STREET 337 1976 $ 54,750 $ 163
3914 PESO DE BURGOS OUTBUILDING 53 ST. GEORGE STREET 260 1976 $ 56,875 $ 218
3915 JOANEDA HOUSE 57 TREASURY STREET 1,424 1806 $ 178,000 $ 125
3916 RODRIGUEZ HOUSE 46 1/2 CUNA STREET 714 1966 $ 22,300 $ 31
3917 BENET HOUSE 65 ST. GEORGE STREET 2,706 1965 $ 84,500 $ 31
3918 COQUINA HOUSE 46 CUNA STREET 2,270 1966 $ 196,875 $ 87
3919 SANCHEZ DE ORTIGOSA HOUSE 60 ST. GEORGE STREET 1,172 1965 $ 250,000 $ 213
3920 DE HITA HOUSE 37 ST. GEORGE STREET 638 1979 $ 99,750 $ 156
3921 GONZALEZ HOUSE 39 ST. GEORGE STREET 519 1979 $ 32,500 $ 63
3922 NEW BLACKSMITH SHOP 37 1/2 ST. GEORGE STREET 242 1983 $ 30,250 $ 125
3923 FLORENCIA HOUSE 33 ST. GEORGE STREET 2,105 1965 $ 460,500 $ 219
3924 SPANISH MILITARY HOSPITAL 2 AVILES STREET 3,522 1965 $ 220,000 $ 62
3925 WATSON HOUSE 206 CHARLOTTE STREET 2,161 1965 $ 270,000 $ 125
3926 SALCEDO KITCHEN 42 1/2 ST. GEORGE STREET 563 1962 $ 52,750 $ 94
3927 SALCEDO HOUSE 42 ST. GEORGE STREET 2,191 1962 $ 274,000 $ 125
3928 GONZALEZ RESTROOMS 35 1/2 ST. GEORGE STREET 182 1983 $ 24,000 $ 132
3929 SIMS HOUSE 12 CUNASTREET 802 1964 $ 125,500 $ 156
3930 SIMS OUTBUILDING 12 CUNA STREET 173 1964 $ 22,000 $ 127
3931 OLD BLACKSMITH SHOP 26 CHARLOTTE STREET 363 1966 $ 117,250 $ 323
3932 HARNESS SHOP 17 CUNA STREET 566 1967 $ 106,000 $ 187
3933 PUBLIC RESTROOMS 40 ST. GEORGE STREET 624 1966 $ 78,000 $ 125
TOTAL ESTIMATED FUNDING REQUIRED: 69,848 GSF $ 5,236,675 $ 17,278,000
GRAND TOTAL REQUESTED FOR DEFERRED MAINTENANCE AND RENOVATIONS: $ 22,514,675
AMOUNT REQUESTED THROUGH LEGISLATIVE BUDGET REQUEST FOR PO&M FUNDING ($7/SQ FT): $ 488,937








Building 3900-GOVERNMENT HOUSE


Address: 48 King Street


Construction Year: 1710

Use: Administrative offices, museum exhibit
Description: This "L" shaped building was completely rebuilt in
1937 with the exception of the coquina walls in the East Wing,
which date from the Colonial Era. The building is a two story,
concrete incased, steel frame structure, with poured-in-place con-
crete floors, covered in most sections with hardwood flooring.
Utility area floors are exposed concrete. The lobby floor is ter-
razzo. A basement lies beneath a section of the west wing. Doors,
windows, and trim are clear cypress in areas not subsequently
modified. The gabled roof is covered with flat clay tile with the
exception of several small sections of built-up flat roof on the east
and west sides of the west wing.

Renovation Estimate: $14,271,000-$550/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. (North Entrance) Install new directional sign on wall near door
directing patrons to only accessible entrance on east side.
2. (North Entrance) Install new hand rails with 1.5 inch O.D. and
extensions at top and bottom
3. (East Entrance) Install sign (with wheelchair pictogram, text
"entrance") at door identifying the entrance as the accessible
entrance. Existing sign not sufficient.
4. (East Entrance) Install automatic door at entrance.
5. (South Entrance) Install directional sign at door that will direct
patrons to the accessible entrance.
6. (South Entrance) Install compliant handrails with correct O.D.
and top and bottom extensions.
7. (Restrooms) Pad exposed supply lines and trap at lavatory.
8. (Restrooms) Mirror is currently too high (bottom edge higher
than 40 inches) install new floor length mirror while keeping
the remaining mirror in place.
9. (Restrooms) Urinal rim is currently too high at 24 inches. Install
compliant urinal.
10. Convert elevator to passenger and investigate feasibility of
installing lift to access the 2nd floor areas not accessible via the
elevator.
11. Install sign at desk/counter notifying patrons that disability
related assistance is available upon request.
12. Develop pamphlet that addresses access issues throughout the
facilities. Pamphlet to be available in various formats (large
print, Braille, audio).


USI-: ZL,94/


ri-


St. Augustine Facility Assessment Report July 2007


Page 3








Building 3900-GOVERNMENT HOUSE, continued

COMPONENT RATING COMMENTS
Ceiling 2 Routine Maintenance Needed basement exposed concrete
Ceiling 4 Major Repairs Needed 1st floor plaster
Ceiling 3 Minor Repairs Needed 2nd floor plaster
Electrical 1- No Work Needed OK
Exterior 4 Major Repairs Needed Poured concrete lintels over windows/doors and beams over the southeast patio
areas have deteriorated to the point that rusting and missing reinforcing steel is
exposed. This condition has significant implications with regards to steel that can-
not be seen inside the remainder of the coquina rock structure. Precast decorative
window trim pieces are cracked and should be replaced, requiring custom fabrica-
S" tion. Wrought iron railings at all upper porches are deteriorated and should be

caused roof damage on lower roofs where scuppers currently empty. Although the
tile roof has been recently replaced, perimeter flashing of flat roofs still has leaks
causing interior and exterior damage. Granite carved walls at entries have pieces
of missing stone and may need complete replacement. Windows appear to be in
good condition and leak free. Fountain on west side of building should either be in
filled or restored to original condition. Existing exit signs contain hazardous mate-
rial and should be replaced along with an assessment of additional exit sign needs.
The museum and basement storage are currently protected by an automatic fire
sprinkler, however, the remainder of the building needs to be sprinkled, which will
require an assessment of the existing pipe sizes and water pressure to the building.
Fenestration 2 Routine Maintenance Needed doors: heavy wood
Fenestration 3 Minor Repairs Needed windows: Wood S.H. 9/9
Fire Code 4 Major Repairs Needed Museum and basement storage are currently sprinkled; verify existing sprinkler
system supply pipe sizes and sprinkle remainder of building.
Verify locations and replace existing EXIT signs with updated units.
Flooring 2 Routine Maintenance Needed basement floor concrete
Flooring 3 Minor Repairs Needed 1st & 2nd floor concrete tile, wood
HVAC 2 Routine Maintenance Needed basement A/C, 1st & 2nd floor heat pump systems
Hazardous 4 Major Repairs Needed OHC Environmental Engineering documents show removal of some thermal system
Materials insulation (TSI) and contaminated soil in the building's crawlspace in May-June of
2000. A 1994 survey by the same company showed chrysotile content in additional
pipe insulation and duct mastic throughout the building.
Interior 2 Routine Maintenance Needed walls: basement plaster masonry
Interior 3 Minor Repairs Needed walls:lst floor Plaster
Interior 3 Minor Repairs Needed walls:2nd floor Plaster
Plumbing 2 Routine Maintenance Needed 1st floor restrooms & kitchen
Plumbing 5 Replacement basement main water supply
Plumbing 2 Routine Maintenance Needed 2nd floor restrooms
Roof 4 Major Repairs Needed built-up
Roof 4 Major Repairs Needed Sloped roofs replaced in 1998-99; some flat roofs have flashing problems at junc-
tures with downspouts.
Roof 3 Minor Repairs Needed sloped clay tile
Site Features 4 Major Repairs Needed Garden walls, constructed of similar coquina block as the main building, have been
deformed and cracked by intrusion of massive tree roots.


St. Augustine Facility Assessment Report July 2007 Page 4


St. Augustine Facility Assessment Report July 2007


Page 4








Building 390 1-DE MESA SANCHEZ HOUSE


Address: 49 St. George Street


GSF: 4,068


Construction Year: 1760

Use: Museum
Description: L-shaped, two-story coquina masonry
structure with masonry gable ends. Wood floors
throughout, with the exception of concrete tabby in
the small east addition. All walls and ceilings are plas-
tered. Wooden balcony over St. George Street. Roof
covered with wood shingles. The structure contains
architectural elements from the First Spanish, British,
Second Spanish, and American Territorial Periods.

Maintenance Estimate: $25,000-$6/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install ramped access to front door off St. George St.
2. If the side door access is used by patrons then a ramp on the out-
side should be installed to provide patron access to the back room
(which is lower than the rest of the first floor). By ramping the en-
try a patron could exit the door and then access the other side door
(ground level).
3. Install stair handrails.
4. Educational materials on second floor. The educational information
on the second floor should be available to patrons that cannot ac-
cess the second floor. A program book with the information should
be developed and available upon request. The publication should
be available in alternate formats.
5. Install sign at stair describing what is on the second floor and in-
form patrons that cannot access the upper level that a program
book is available.
Ceiling 2 Routine Maintenance Needed Gyp Board on rafters
Electrical 1 No Work Needed OK
Exterior 1 No Work Needed Recent paint, building in relatively good condition.
Exterior 1- No Work Needed Walls: Stucco
Fenestration 2 Routine Maintenance Needed Windows: Wood S.H. 9/6
Fenestration 2 Routine Maintenance Needed Doors: Exterior solid board
Fire Code 2 Routine Maintenance Needed Replace and add additional exit signs.
Flooring 2 Routine Maintenance Needed wood
HVAC 2 Routine Maintenance Needed Heat Pump
Asbestos survey by ATS Environmental in November, 1994 revealed no
Hazardous Materials 1- No Work Needed asbestos present.
Interior 2 Routine Maintenance Needed Walls: Plaster
Plumbing 1 No Work Needed None
Roof 2 Routine Maintenance Needed Wood shakes


St. Augustine Facility Assessment Report July 2007


Page 5




Building 390 1-DE MESA SANCHEZ HOUSE-Photos

El P._M


St. Augustine Facility Assessment Report July 2007 Page 6


St. Augustine Facility Assessment Report July 2007


Page 6








Building 3902-ARRIVAS HOUSE


Address: 46 St. George Street


GSF: 4,041


Reconstruction Year: 1961

Use: Retail & Museum Administration
Description: Coquina masonry walls on the first
floor, wood frame covered with lapped siding on sec-
ond floor. Gable roof covered with wood shingles. A
wooden balcony virtually surrounds the second floor.
Concrete tabby floors on first floor, wood floors on
second floor and attic. Exposed wood beam ceiling
on the first floor, plaster walls and ceilings throughout
the balance of the building. Separate central heat and
air conditioning for all three floors.

Maintenance Estimate: $885,000-$219/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install ramp at main door off St. George St (5 inch step).
2. Install handrails at stairs to upper levels.
3. Grade ground surfaces in the courtyard leading to the upper levels.
Electrical 2 Routine Maintenance Needed Electrical: normal maintenance
Exterior 1 No Work Needed Decks and porches are new. Gable roof ends recently reconstructed in
cypress.
Exterior 2 Routine Maintenance Needed Walls: Exposed masonry
Exterior 2 Routine Maintenance Needed Walls: Stone
Fenestration 2 Routine Maintenance Needed Doors: Panel doors
Fenestration 1- No Work Needed Windows: 1st floor casement 2x8
Fenestration 3 Minor Repairs Needed Windows: 2nd floor 4 over 3 D.H
Fenestration 1- No Work Needed Windows: 3rd floor 4 over 3 D.H.
Fire Code 5 Replacement Need automatic sprinkler system. Additional exit signs may be required.
Flooring 3 Minor Repairs Needed 1st floor concrete, 2nd floor wood, 3rd floor wood
HVAC 2 Routine Maintenance Needed Mechanical:2 straight cool systems
Hazardous Materials 3 Minor Repairs Needed Asbestos survey by ATS Environmental in November, 1994 revealed vinyl
asbestos floor tile (mastic not tested).
Interior 2 Routine Maintenance Needed 2nd floor ceiling needs plaster repairs. Air handling unit needs to be re-
zoned to segregate floors.
Interior 3 Minor Repairs Needed Walls: 1st floor Plaster
Interior 2 Routine Maintenance Needed Walls: 3rd floor Plaster
Interior 2 Routine Maintenance Needed Walls: 1st floor Plaster
Interior 3 Minor Repairs Needed Ceiling: 2nd floor Plaster
Interior 2 Routine Maintenance Needed Ceiling: 1st floor Board on joist
Interior 2 Routine Maintenance Needed Ceiling: 3rd floor Plaster
Plumbing 3 Minor Repairs Needed Plumbing: 2 bathrooms 3rd floor
Roof 4 Major Repairs Needed Roof: Wood shakes


St. Augustine Facility Assessment Report July 2007


Page 7







Building 3902-ARRIVAS HOUSE-Photos


St. Augustine Facility Assessment Report July 2007 Page 8


St. Augustine Facility Assessment Report July 2007


Page 8








Building 3903-PAREDES DODGE HOUSE

I Address: 54 St. George Street


GSF: 1,392


Construction Year: 1808

Use: Retail
Description: One and one-half story with coquina ma-
sonry walls, masonry gables with wood shingle roof.
Shares a common wall with the building to the north. Ex-
posed beam ceiling on first floor. Plastered walls. Some
plumbing on second floor. Window units are used for cli-
mate control. Minimal electric service.

Renovation Estimate: $1,325,000-$952 Sq/Ft


St. Augustine Facility Assessment Report July 2007 Page 9


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install platform and ramp at main door off St. George St.
Electrical 1 No Work Needed OK
Exterior 4- Major Repairs Needed Building needs full restoration. Evidence of termite damage with active
infestation.
Exterior 3 Minor Repairs Needed Walls: Exposed masonry
Fenestration 2 Routine Maintenance Needed Doors: Exterior solid board
Fenestration 5 Replacement Windows: Fixed sash
Fire Code 3 Minor Repairs Needed Requires automatic sprinkler system.
Flooring 4 Major Repairs Needed 1st floor concrete
Flooring 5 Replacement 2nd floor plywood
HVAC 2 Routine Maintenance Needed 2nd floor Heat Pump system
Hazardous Materials 4 Major Repairs Needed Asbestos survey by ATS Environmental in November, 1994 revealed as-
bestos present in roofing material.
Interior 3 Minor Repairs Needed Walls: 1st floor Plaster, 2nd floor exposed roof
Interior 1- No Work Needed Ceiling: 1st floor Board on joist
Interior 3 Minor Repairs Needed Ceiling: 2nd floor Board on joist
Plumbing 1- No Work Needed None
Roof 5 Replacement Roof: Wood shakes. Deteriorating due to improper material and/or in-
stallation. Total replacement required at next maintenance cycle. Pro-
_ected life less than 5 years.


St. Augustine Facility Assessment Report July 2007


Page 9








Building 3904-DODGE OUTBUILDING


Address: 54 1/2 St. George Street


GSF: 231


Construction Year: Unknown

Use: Rental
Description: Frame, one story gable end, wood
floor.

Renovation Estimate: $0


COMPONENT RATING COMMENTS
Electrical 1- No Work Needed OK
Exterior 4 Major Repairs Needed Evidence of termite damage
Exterior 5 Replacement Walls: Board & Batten E&N, Metal Siding S&W
Fenestration 2 Routine Maintenance Needed Windows: Wood S.H.
Fenestration 2 Routine Maintenance Needed Doors: wood dutch door
HVAC 2 Routine Maintenance Needed window A/c
Interior 5 Replacement Plywood floor rotting
Interior 4 Major Repairs Needed Walls: gyp board
Interior 2 Routine Maintenance Needed Ceiling: exposed rafters
Plumbing 1- No Work Needed one sink
Roof 5 Replacement 5-v crimp metal


St. Augustine Facility Assessment Report July 2007 Page 10


St. Augustine Facility Assessment Report July 2007


Page 10








Building 3905-GALLEGOS HOUSE


Address: 21 St. George Street


GSF: 905


Reconstruction Year: 1963

Use: Museum Interpretation
Description: One story poured tabby concrete walls
with exterior stucco finish. Built-up flat roof. Board
covered shed roof over loggia. Exposed beam ceiling.
Plastered interior walls. Tabby concrete floors. Con-
cealed utility electric service at rear of yard. No
plumbing or HVAC.

Maintenance Estimate: $198,000-$219/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Grade natural path walkway in and around the exhibit trail provide access to
the concrete pad surface to home. This may require a ramp (concrete prefera-
bly).
Ceiling 1- No Work Needed Ceiling: board on Purlins
Electrical 1- No Work Needed None
Exterior 5 Replacement Walls: Exterior Plaster on concrete
Exterior 5 Replacement Porch- roof (wood shakes), framing & posts, termite damage evident
Fenestration 1 No Work Needed Doors: Exterior solid board
Fenestration 1- No Work Needed Windows: Wood Shutters
Fire Code 1 No Work Needed No automatic fire sprinkler system needed since furniture is reproduction.
Flooring 1- No Work Needed Concrete
HVAC 1- No Work Needed None
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no asbestos
present.
Interior 1 No Work Needed Walls: Interior Plaster on concrete
Plumbing 1- No Work Needed None
Roof 5 Replacement Built-up






S i i e R JP


St. Augustine Facility Assessment Report July 2007


Page I I







Building 3905-GALLEGOS HOUSE-Photos


I.


St. Augustine Facility Assessment Report July 2007 Page 12


St. Augustine Facility Assessment Report July 2007


Page 12








Building 3906-RIBERA HOUSE


Address: 22 St. George Street


GSF: 2,168


Reconstruction Year: 1964

Use: Retail
Description: Two story coquina masonry structure with a
flat roof. Plastered interior walls on both floors. Exposed
beam ceiling on first floor, plastered ceiling on second floor.
Tabby concrete floor on first floor, wood floor on second.
Most doors and exterior shutters are antique pieces from
Mexico. Central heat and air for both floors. Adequate
wiring for current use. No plumbing.
Maintenance Estimate: $271,000-$125/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Ramp entrance from street to courtyard and plaza.
2. Grade surface from courtyard walkway to kitchen.
3. Install ramped surface at entry to kitchen (2 to 3 inch sill).
4. Install handrails at second floor stair.
Electrical 1 No Work Needed OK
Exterior 5- Replacement Walls: Plaster on masonry
Fenestration 3 Minor Repairs Needed Doors: wood panel doors
Fenestration 2 Routine Maintenance Needed Windows: Wood Shutters 2-panel
Fire Code 5 Replacement Needs automatic sprinkler system.
Flooring 2 Routine Maintenance Needed 1st floor concrete, 2nd floor wood
HVAC 3 Minor Repairs Needed package A/C on roof
Hazardous Materials 1- No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 3 Minor Repairs Needed Damaged ceiling on second floor from previous roof leak needs replace-
ment.
Interior 4 Major Repairs Needed Ceiling:lst floor board & purlin
Interior 3 Minor Repairs Needed Ceiling: 2nd floor Gyp Board on joists
Interior 3 Minor Repairs Needed Walls: 2nd floor Plaster
Interior 2 Routine Maintenance Needed Walls: 1st floor Plaster
Plumbing 1- No Work Needed None
Roof 4 Major Repairs Needed Built-up






St. A


St. Augustine Facility Assessment Report July 2007


Page 13





Building 3906-RIBERA HOUSE


a A I I


St. Augustine Facility Assessment Report July 2007 Page 14


St. Augustine Facility Assessment Report July 2007


Page 14


-I
~e~ r~r








Building 3907-RIBERA KITCHEN


Address: 22 St. George Street


GSF: 480


Reconstruction Year: 1964

Use: Retail
Description: one story coquina masonry structure
with a flat roof and tabby concrete floor, exposed
beam ceiling, and plastered interior walls. Climate
control is supplied by a window unit. Adequate wir-
ing but no plumbing.
Maintenance Estimate: $85,500-$178/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Ramp entrance from street to courtyard and plaza.
2. Grade surface from courtyard walkway to kitchen.
3. Install ramped surface at entry to kitchen (2 to 3 inch sill).
Electrical 1- No Work Needed OK
Exterior 2 Routine Maintenance Needed Walls: Plaster on masonry
Fenestration 2 Routine Maintenance Needed Windows: casement double 2x8
Fenestration 2 Routine Maintenance Needed Doors: board and cross buck
Flooring 1- No Work Needed Concrete
HVAC 1- No Work Needed window shaker
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 3 Minor Repairs Needed Walls: Plaster
Interior 3 Minor Repairs Needed Ceiling: Board on purlins
Plumbing 1- No Work Needed None
Roof 5 Replacement needs replacement
Roof 2 Routine Maintenance Needed Built-up


St. Augustine Facility Assessment Report July 2007 Page I 5


St. Augustine Facility Assessment Report July 2007


Page 15








Building 3908-TRIAY HOUSE


Address: 29 St. George Street


GSF: 690


Reconstruction Year: 1964

Use: Museum Store
Description: One-story, with stuccoed concrete
block masonry walls and gables. Wood shingle roof.
Simulated tabby concrete floors. Plastered walls.
Central heat and air. Electric service adequate for
current use. No plumbing.
Maintenance Estimate: $ 106,875-$ 155/Sq Ft


St. Augustine Facility Assessment Report July 2007 Page I 6


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Entrance: This facility has entrance on the south side of the building with
a 3 to 4 inch step up.
Recommendation:
1. Ramp step into facility.
Ceiling 1- No Work Needed plaster
Electrical 1- No Work Needed OK
Exterior 4 Major Repairs Needed wood trim at fascia is decayed and needs replacement.
Exterior 1- No Work Needed Walls: plaster on concrete
Fenestration 4 Major Repairs Needed Doors: Wood door
Fenestration 4 Major Repairs Needed Windows: S. H. 9/9
Flooring 1 No Work Needed concrete
HVAC 4 Major Repairs Needed Heat Pump
Hazardous Materials 4 Major Repairs Needed Asbestos survey by ATS Environmental in November, 1994 revealed as-
bestos present in gray cementitious roofing material.
Interior 1- No Work Needed Walls: plaster on concrete
Plumbing 1- No Work Needed None
Roof 5 Replacement Wood shakes over asbestos sheeting. Deteriorating due to improper
material and/or installation. Total replacement required at next mainte-
nance cycle. Projected life less than 5 years.


St. Augustine Facility Assessment Report July 2007


Page 16







Building 3908-TRIAY HOUSE-Photos


St. Augustine Facility Assessment Report July 2007 Page I 7


St. Augustine Facility Assessment Report July 2007


Page 17










Address: 27 St. George Street


GSF: 314


Reconstruction Year: 1964

Use: Museum Interpretation
Description: One story wood post and beam with
lapped vertical wood siding and gable ends. No inte-
rior wall finish. Roof covered with wood shingles.
Wood floor. No electric service, no plumbing.
Maintenance Estimate: $57,750-$ 184/Sq Ft


St. Augustine Facility Assessment Report July 2007 Page 18


Building 3909-GOMEZ HOUSE


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install platform and ramp at entrance.
2. Grade exterior path to the concrete pad to allow for grade level access
(preferably concrete ramp).
Ceiling 1- No Work Needed Board on Purlins
Electrical 1- No Work Needed None
Exterior 5 Replacement Walls: Exterior Board & Bat needs replacement over 50% siding
Fenestration 2 Routine Maintenance Needed Doors: Board on ladder
Fenestration 2 Routine Maintenance Needed Windows: Wood Shutters
Flooring 1- No Work Needed Wood wide board
HVAC 1- No Work Needed None
Hazardous Materials 4- Major Repairs Needed Asbestos survey by ATS Environmental in November, 1994 revealed asbes-
tos present in gray cementitious roofing material.
Interior 1- No Work Needed Walls: Board
Plumbing 1- No Work Needed None
Roof 5 Replacement Wood shakes on sheathing. Deteriorating due to improper material and/or
installation. Total replacement required at next maintenance cycle. Pro-
jected life less than 5 years.


St. Augustine Facility Assessment Report July 2007


Page 18








Building 3910-CERVEAU HOUSE

Address: 26 Cuna Street

LConstruction Year: 1885


GSF: 3,059

Use: Retail


Description: Two-story wood frame structure covered with bev-
eled siding. Hipped roof covered with wood shingles. Wood bal-
cony and porch on east and south sides. One story lean-to addi-
tion to rear. Wood floors, plaster walls and ceilings throughout.
Separate central heat and air conditioning on both floors. Rest
rooms on both floors. Exterior wood stairs on rear. Wiring ade-
quate for current use. Sprinkler system.
Renovation Estimate: $1,682,000-$5501Sq Ft

COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install directional signage at main stair to direct patrons to side east
side ramp entrance. On the sign install the wheelchair pictogram with
an arrow pointing to the direction of the ramp.
2. Install compliant sill to the store entrance.
3. Install compliant handrail at the stair to the apartment.
4. Install compliant handrails on both sides at east side ramp.
Electrical 1 No Work Needed OK
Exterior 5 Replacement Rear porch/stairway decayed and need replacement. Exterior needs paint.
Exterior 4- Major Repairs Needed walls: clapboard
Exterior 5 Replacement External stairs to apt.
Fenestration 2 Routine Maintenance Needed panel doors, wood S.H.6/6
Fire Code 5 Replacement Needs automatic sprinkler system.
Flooring 2 Routine Maintenance Needed wood
HVAC 2 Routine Maintenance Needed 1st floor straight cool system, 2nd floor straight cool system
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 2 Routine Maintenance Needed walls: plaster
Interior 2 Routine Maintenance Needed ceiling: plaster
Plumbing 1 No Work Needed 1st floor bathroom and water heater
Plumbing 3 Minor Repairs Needed 2nd floor bathroom & Kitchen
Roof 4 Major Repairs Needed wood shakes. Deteriorating due to improper material and/or installation.
Total replacement required at next maintenance cycle. Projected life less
than 10 years.


St. Augustine Facility Assessment Report July 2007 Page I 9


St. Augustine Facility Assessment Report July 2007


Page 19







Building 391 I-HAAS HOUSE

Stl I Address: 28 Cuna Street


GSF: 2,336


Construction Year: 1850

Use: Retail
Description: Two-story frame house with beveled siding. Ga-
ble ends with wood shingle roof. Plaster walls and ceiling on
both floors. Wood floors throughout. Central heat and air
on both floors. Bathrooms on both floors. Minimal electric
service. Exterior wood stairs on rear.
Maintenance Estimate: $51 1,000-$219/Sq Ft


:r- S
St. ugusineFaciity ssesmen Reort Jul 207 Pae 2


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Upgrade ramp to facility and install compliant handrails.
2. Upgrade sill at store entrance with a new sloped sill.
3. Install handrails to apartment (no handrails at present).
4. The issue of pedestrian access should be discussed with the City.
Currently it is very difficult for a pedestrian to access any shops on
this part of Cuna St.
Electrical 2 Routine Maintenance Needed smoke alarm hanging
Exterior 3 Minor Repairs Needed Walls: clapboard
Fenestration 2 Routine Maintenance Needed Doors: solid wood
Fenestration 3 Minor Repairs Needed Windows: Wood S.H. 1/1
Flooring 3 Minor Repairs Needed wood board
HVAC 2 Routine Maintenance Needed 1st floor straight cool & gas furnace (disc.)
HVAC 2 Routine Maintenance Needed 2nd floor straight cool unit, 2nd floor bathroom & kitchen
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 2- Routine Maintenance Needed Ceiling: plaster
Interior 3 Minor Repairs Needed Walls: plaster
Plumbing 2 Routine Maintenance Needed 1st floor bathroom & fire system
Roof 5 Replacement wood shakes. Deteriorating due to improper material and/or installa-
tion. Total replacement required at next maintenance cycle. Projected
life less than 5 years.


St. Augustine Facility Assessment Report July 2007


Page 20





Building 391 I-HAAS HOUSE-Photos






Li-j!


St. Augustine Facility Assessment Report July 2007 Page 21


St. Augustine Facility Assessment Report July 2007


Page 21








Building 3912-PESO DE BURGO / PELLICER HOUSE


Address: 53 St. George Street


GSF: 682


Reconstruction Year: 1976

Use: Spanish Quarter Museum
Description: Main building and two outbuildings are wood
post and beam construction covered with beveled pine sid-
ing. Gable end roofs are covered with wood shingles. The
interior of the main building has plastered walls, and an ex-
posed beam ceiling.
Maintenance Estimate: $340,750-$499/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install platform and ramp at front door to allow for easy access for
all patrons.
2. If ramp not installed in front then appropriate directional and infor-
mation signage needs to be installed at door that will inform patrons
how to access the property.
3. With alternate side access the sidewalks to the rear ramp will need
to be upgraded. (At present the sidewalks are only 36 inches wide.)
4. Replace current rear access ramp to main facility (even if new ramp
is installed at the front entrance).
5. Replace small ramp with compliant ramp at the rear building.
6. From this point people pass along a dirt path to other facilities. The
current crushed stone natural path walkway needs to be upgraded
to something more user friendly. In the current state there are trip
hazards and uneven areas.
7. In the event that the steps in the front are maintained then install
handrails at entrance.
Ceiling 2 Routine Maintenance Needed Gyp Board on rafters
Electrical 1- No Work Needed OK
Exterior 5 Replacement Walls: Clapboard Outside Gyp Board inside (on studs?)
Exterior 3 Minor Repairs Needed Siding on building is custom shaped cypress. 20% of siding is rotten and
needs replacing.
Flooring 2 Routine Maintenance Needed Wood
HVAC 2 Routine Maintenance Needed Heat Pump
Hazardous Materials 1- No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 2 Routine Maintenance Needed Walls: Gyp Board both sides (on studs?)...
Plumbing 1- No Work Needed None
Roof 4 Major Repairs Needed Wood shakes. Deteriorating due to improper material and/or installa-
tion. Total replacement required at next maintenance cycle. Projected
life less than 10 years.
Site Features 4 Major Repairs Needed Drainage on front of the building allowing water to damage siding. Sug-
gested trench drain to intercept rain water.
Foundation deteriorated and needs to be replaced by jacking building up
for new construction.

St. AuutnIaiiyAssmntRpr uy20 ae2


St. Augustine Facility Assessment Report July 2007


Page 22












Building 3912-PESO DE BURGO / PELLICER HOUSE-Photos


-C_,._____
I---,,____~ ~---~
----,---,
--'--
----
'-------------`------1
-~~----
------------------e I--
----~
-I,,,,_ ----.
c-lr '---------4-_
--~------~ --- ----- --~U---_-~--_-~______
-F--~--- ---~~-~~-~, ~
~-~---C-~------~~_
'-~c----~----~
-- -C~--- ____


St. Augustine Facility Assessment Report July 2007 Page 23


St. Augustine Facility Assessment Report July 2007


Page 23








Building 3913-PESO DE BURGO N OUTBUILDING


Address: 53 St. George Street


GSF: 337


Reconstruction Year: 1976

Use: Spanish Quarter Museum
Description: The outbuilding are unfinished on the inside. All
have wooden floors. Functional fireplace in north outbuilding.
Maintenance Estimate: $54,750-$163/Sq Ft


RATING


COMMENTS


ADA 3 Minor Repairs Needed Recommendations:
1. With alternate side access the sidewalks to the rear ramp will need
to be upgraded. (At present the sidewalks are only 36 inches wide.)
2. Replace small ramp with compliant ramp at the rear building.
3. From this point people pass along a dirt path to other facilities. The
current crushed stone natural path walkway needs to be upgraded
to something more user friendly. In the current state there are trip
hazards and uneven areas.
Ceiling 2 Routine Maintenance Needed Board on joist
Electrical 1- No Work Needed None
Exterior 4 Major Repairs Needed Walls: Clapboard Outside Plaster inside on stud
Exterior 1- No Work Needed Walls: Plaster in masonry
Fenestration 2 Routine Maintenance Needed Doors: Exterior board, Windows: Wood Shutters
Flooring 2 Routine Maintenance Needed Wood
HVAC 1- No Work Needed None
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Plumbing 1- No Work Needed None
Roof 4 Major Repairs Needed Wood shakes. Deteriorating due to improper material and/or installa-
tion. Total replacement required at next maintenance cycle. Projected
life less than 10 years.














St. ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ k AuutieFaiit sesmntRpot-Juy207Pae2


St. Augustine Facility Assessment Report July 2007


Page 24








Building 3914-PESO DE BURGO S OUTBUILDING


Address: 53 St. George Street


GSF: 260


Reconstruction Year: 1976

Use: Spanish Quarter Museum/Staff Lounge
Description: The outbuilding are unfinished on the inside.
All have wooden floors. Window unit in the south outbuild-
ing. Toilet in south outbuilding.
Maintenance Estimate: $56,875-$218/Sq Ft


St. Augustine Facility Assessment Report July 2007 Page 25


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. When the new ramp to 3912 is installed then access to this facility
should be reviewed. Install compliant ramped access.
Ceiling 2 Routine Maintenance Needed Gyp Board on rafters
Exterior 5 Replacement Walls: Clapboard Outside Gyp Board inside (on studs?)
Fenestration 2 Routine Maintenance Needed Doors: Exterior solid board, Windows: Wood S.H. 9/6
Flooring 2 Routine Maintenance Needed Wood
HVAC 2 Routine Maintenance Needed Window AC
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed as-
bestos no present.
Interior 2 Routine Maintenance Needed Walls: Gyp Board both sides (on studs?)
Plumbing 2- Routine Maintenance Needed One Restroom
Roof 5 Replacement Wood shakes. Deteriorating due to improper material and/or installa-
tion. Total replacement required at next maintenance cycle. Projected
life less than 5 years.


St. Augustine Facility Assessment Report July 2007


Page 25








Building 3915-JOANEDA HOUSE


Address: 57 Treasury Street

Construction Year: 1806

Use: Residential Rental


GSF: 1,424


Description: One story, coquina masonry with finished
attic space. Loggia on south side. Gable roof with wood
shakes. Exposed beam ceiling, plastered walls. Central
heat and air. Kitchen, living, and dining areas on first floor,
bedroom in attic space. Bath facilities on both floors. Elec-
tric service adequate for current use.
Maintenance Estimate: $178,000-$125/Sq Ft


St. Augustine Facility Assessment Report July 2007 Page 26


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Provide street level access to property (can leave as is due to occu-
pancy).
2. Make no changes to the structure.
Electrical 2 Routine Maintenance Needed no GFI's at sink
Exterior 2 Routine Maintenance Needed Walls: plaster on masonry
Fenestration 2 Routine Maintenance Needed Windows: wood S.H. 6/6, Doors: solid wood
Flooring 2 Routine Maintenance Needed wood
HVAC 2 Routine Maintenance Needed 2 straight cool systems
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 2 Routine Maintenance Needed Walls: plaster, Ceiling: plaster
Plumbing 3 Minor Repairs Needed one kitchen, 2 bathrooms
Roof 5 Replacement Wood shakes. Deteriorating due to improper material and/or installation.
Total replacement required at next maintenance cycle. Projected life less
than 5 years.
Roof 5 Replacement Possible candidate for replacement........covered with moss on north side.
Slope on dormers not code-compliant, too shallow.


St. Augustine Facility Assessment Report July 2007


Page 26








Building 3916-RODRIGUEZ HOUSE

1 Address: 46 1/2 Cuna Street


GSF: 714


Reconstruction Year: 1966

Use: Leased Storage
Description: One-story, stuccoed concrete block
masonry walls with flat roof. Exposed, round pole
ceiling joists. Plaster walls. Wall mounted HVAC.
Electric service adequate for current use.
Maintenance Estimate: $22,300-$3 I/Sq Ft


COMPONENT RATING COMMENTS
ADA 1- No Work Needed This is a leased storage facility off a crushed lime stone parking area.
When and if the occupancy changes it would be possible to provide ac-
cess via a ramp to the entrance.
Electrical 1- No Work Needed OK
Exterior 2 Routine Maintenance Needed Walls: Plaster on Masonry (conc.?)
Exterior 3 Minor Repairs Needed some siding needs to be replaced
Fenestration 2 Routine Maintenance Needed windows: wood shutters
Fenestration 2 Routine Maintenance Needed doors: solid wood
Flooring 2 Routine Maintenance Needed concrete
HVAC 2 Routine Maintenance Needed mini split system
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 2 Routine Maintenance Needed Ceiling: board on timber purlins
Interior 2- Routine Maintenance Needed Walls: Plaster
Plumbing 1- No Work Needed one sink
Roof 5 Replacement Built-up roof on 1x8 sheathing

















-

"St."Augustine Facility Asses-sm-entRpor- Jul-y200 '.Page-.2


St. Augustine Facility Assessment Report July 2007


Page 27








Building 3917-BENET HOUSE


Address: 65 St. George Street


GSF: 2,706


Reconstruction Year: 1965

Use: Rental-I st floor retail, 2nd floor residential
Description: A two-story stuccoed concrete block ma-
sonry building with wood balcony over St. George Street.
Interior plaster walls, wood floors throughout. Exposed
beam ceiling on first floor. Fire place on first and second
floors. Wood shingle roof with masonry gable ends. Sepa-
rate central heat and air conditioning systems for both
floors. Separate Electric service for each floor, adequate
for current use. Toilet facilities on first floor, full bath on
second floor.
Maintenance Estimate: $84,500-$3 I/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install platform and ramp off one of the entrances to the store.
Ceiling 3 Minor Repairs Needed some damage on ceiling in second floor apartment from previous roof
leak.
Electrical 2 Routine Maintenance Needed routine maintenance
Exterior 2 Routine Maintenance Needed Walls: Plaster on masonry
Exterior 4 Major Repairs Needed rotten gate at privacy wall.
Fenestration 2 Routine Maintenance Needed doors: wood panel doors
Fenestration 3 Minor Repairs Needed windows: Wood S.H. 9/9
Flooring 2 Routine Maintenance Needed 1st floor VCT & concrete, 2nd floor wide wood 8" boards
HVAC 2 Routine Maintenance Needed straight cool system; refrigeration chamber outside
Hazardous Materials 5 Replacement Asbestos survey by ATS Environmental in November, 1994 revealed as-
bestos present in gray cementitious roofing material.
Interior 2 Routine Maintenance Needed Walls:lst floor Plaster
Interior 3 Minor Repairs Needed Walls:2nd floor Plaster
Interior 2 Routine Maintenance Needed Ceiling: 1st floor wood on purlins
Interior 3 Minor Repairs Needed ceiling: 2nd floor Plaster
1st floor water heater, washer, outside sink; 2nd floor bathroom and
Plumbing 2 Routine Maintenance Needed kitchen
Roof 2 Routine Maintenance Needed Wood shakes on asbestos sheets. Deteriorating due to improper mate-
rial and/or installation. Total replacement required at next maintenance
cycle.
Roof 1- No Work Needed Recently replaced


St. Augustine Facility Assessment Report July 2007 Page 28


St. Augustine Facility Assessment Report July 2007


Page 28







Building 3917-BENET HOUSE-Photos


St. Augustine Facility Assessment Report July 2007 Page 29


St. Augustine Facility Assessment Report July 2007


Page 29








Building 3918-COQUINA HOUSE


Address: 46 Cuna Street


GSF: 2,270


Reconstruction Year: 1966

Use: Maintenance Shop
Description: One-story stuccoed concrete block ma-
sonry. Vertical board gable ends. Wood shingle roof. At-
tic storage. Wood floors. Painted plywood ceiling. Toilet
on first floor. Central HVAC system. Stuccoed concrete
block masonry flat roof addition on east side. No interior
finish. Electric service adequate for current use.
Maintenance Estimate: $196,875-$87/Sq Ft


COMPONENT RATING COMMENTS
ADA 1- No Work Needed This structure is currently used as a City workshop. There is no public
access to the space. There are two entrances to this facility and each has
a 2 to 4 inch step up.
Recommendations: Make no changes to the property at present.
Electrical 2 Routine Maintenance Needed Conduit not secure North wall
Exterior 4- Major Repairs Needed Walls: vertical boards
Exterior 2 Routine Maintenance Needed Walls: plaster on masonry
Fenestration 3 Minor Repairs Needed Windows: Wood S.H. 12/12
Fenestration 3 Minor Repairs Needed Doors: board on cross buck
Fire Code 5 Replacement Due to nature of stored materials, automatic sprinkler system is needed.
Flooring 2- Routine Maintenance Needed Concrete
HVAC 2 Routine Maintenance Needed Heat pump system in attic
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 2 Routine Maintenance Needed Ceilings: plaster
Interior 2 Routine Maintenance Needed Walls: plaster
Plumbing 2 Routine Maintenance Needed One water cooler
Plumbing 2 Routine Maintenance Needed One bathroom
wood shakes. Deteriorating due to improper material and/or installa-
tion. Total replacement required at next maintenance cycle. Projected
Roof 5 Replacement life less than 10 years.
Roof 3 Minor Repairs Needed Garage built-up


St. Augustine Facility Assessment Report July 2007 Page 30


St. Augustine Facility Assessment Report July 2007


Page 30








Building 3919-SANCHEZ DE ORTIGOSA HOUSE


Address: 60 St. George Street


GSF: 1,172


Reconstruction Year: 1965

Use: Rental, retail
Description: One story, stuccoed concrete block masonry
with flat roof. Exposed beam ceiling with ceramic tile.
Maintenance Estimate: $250,000-$213/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed There is a 7 inch step up into the facility from St. George St. Area could
be ramped.
Recommendations: Install platform and ramp at store entrance.
Ceiling 5 Replacement Exposed beam and purlin
Electrical 1- No Work Needed OK
Exterior 1- No Work Needed Walls: plaster and masonry
Exterior 2 Routine Maintenance Needed Walls: frame board & batten
Fenestration 2 Routine Maintenance Needed Doors: solid wood doors
Fenestration 2 Routine Maintenance Needed Windows: 2x8 casement windows
Flooring 5 Replacement Mexican tile
HVAC 2 Routine Maintenance Needed Heat Pump system
Hazardous Materials 3 Minor Repairs Needed Asbestos survey by ATS Environmental in November, 1994 revealed as-
bestos present in black tar of built-up roofing material.
Interior 1- No Work Needed Walls: Plaster & masonry
Plumbing 3 Minor Repairs Needed One bathroom
Roof 5 Replacement Attached shed roof-Wood shake
Roof 3 Minor Repairs Needed Built-up on plywood


St. Augustine Facility Assessment Report July 2007 Page 3 I


St. Augustine Facility Assessment Report July 2007


Page 31








Building 3920-DE HITA HOUSE

-Address: 37 St. George Street


GSF: 638


Reconstruction Year: 1979

Use: Museum Interpretation
Description: The two buildings have stuccoed concrete
block masonry walls. The de Hita House has a hip roof
covered with wood shingles. Both have open loggias and
tabby concrete floors, plastered interior walls, exposed
beam ceilings and central heat.
Maintenance Estimate: $99,750-$ I 56/Sq Ft


St. Augustine Facility Assessment Report July 2007 Page 32


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations: Grade exterior path and provide access to front
door concrete pad (3 to 4 inch step up).
Ceiling 1- No Work Needed board on purlins
Electrical 1- No Work Needed OK
Exterior 1- No Work Needed Walls: plaster on masonry
Exterior 1 No Work Needed Walls: board on wood stud
Exterior 4 Major Repairs Needed Some termite damage on exterior warrants replacement of some siding
and columns. Wooden door sills need repair or replacement.
Exterior 5 Replacement Walls: replace posts (termites)
Fenestration 2 Routine Maintenance Needed Doors: board on cross buck
Fenestration 2 Routine Maintenance Needed Windows: 2-panel shutters
Fenestration 1- No Work Needed Doors: 3-panel door
Flooring 2 Routine Maintenance Needed concrete
HVAC 1- No Work Needed None
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 1- No Work Needed Walls: plaster on masonry
Plumbing 1- No Work Needed None
Roof 4- Major Repairs Needed Wood shakes. Deteriorating due to improper material and/or installa-
tion. Total replacement required at next maintenance cycle. Projected
life less than 10 years.


St. Augustine Facility Assessment Report July 2007


Page 32






Building 3920-DE HITA HOUSE-Photos

III ~ ?;~:~;x mq-*~=


I ;
~~v;~~ ~o~t~ ---~~ ~cr~.-.c~s~a.- ~d~r:
i' ~~~Js'... .I ~'1. ...
I "i'. -i


SA i F lo Jul 2007P


St. Augustine Facility Assessment Report July 2007


Page 33








Building 392 I -GONZALEZ HOUSE

Address: 39 St. George Street GSF: 519

Reconstruction Year: 1979

Use: Museum Interpretation
Description: The two buildings have stuccoed concrete
block masonry walls. The Gonzalez House a flat roof.
Both have open loggias and tabby concrete floors, plas-
tered interior walls, exposed beam ceilings and central
heat.
Maintenance Estimate: $32,500-$63/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Replace noncompliant sill ramp at main entrance.
2. Ramp the rear exit that leads to the exterior restrooms.
Ceiling 1- No Work Needed Board on purlins
Exterior 1 No Work Needed Walls: Plaster on masonry
Fenestration 1 No Work Needed Doors: Board door
Fenestration 1- No Work Needed Windows: Board on ladder
Flooring 2 Routine Maintenance Needed Concrete
HVAC 3 Minor Repairs Needed Straight cool
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 1- No Work Needed Walls: plaster on masonry
Plumbing 1- No Work Needed None
Roof 3 Minor Repairs Needed Built-up


St. Augustine Facility Assessment Report July 2007 Page 34


St. Augustine Facility Assessment Report July 2007


Page 34








Building 3922-NEW BLACKSMITH SHOP

.- A Address: 37 1/2 St. George Street


GSF: 242


Reconstruction Year: 1983

Use: Museum Interpretation
Description: Poured tabby concrete walls. Hip roof covered
with wood shingles. Dirt floor. Electric service adequate for
current use. No plumbing or HVAC.
Maintenance Estimate: $30,250-$125/Sq Ft


St. Augustine Facility Assessment Report July 2007 Page 35


COMPONENT RATING COMMENTS
ADA 2 Routine Maintenance Needed Entrance: The entrance to this facility is by natural crushed rock walkway.
Recommendations: Grade exterior walkways.
Ceiling 3 Minor Repairs Needed wood shakes on poles and beams
Electrical 1 No Work Needed None
Exterior 1- No Work Needed Stone masonry
Fenestration 2 Routine Maintenance Needed Windows: Heavy Timber Wood Shutters
Fenestration 2 Routine Maintenance Needed Doors: Heavy Timber Wood doors
Flooring 1- No Work Needed concrete
HVAC 1- No Work Needed None
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Plumbing 1- No Work Needed None
Roof 4 Major Repairs Needed Wood shakes. Deteriorating due to improper material and/or installation.
Total replacement required at next maintenance cycle. Projected life less
than 10 years.
Roof 3 Minor Repairs Needed North side of roof moss covered; needs replacement. Roof trim deterio-
rated and needs replacement.


St. Augustine Facility Assessment Report July 2007


Page 35








Building 3923-FLORENCIA HOUSE


Address: 33 St. George Street


GSF: 2,105


Reconstruction Year: 1965

Use: Museum store and staff support facilities
Description: One-story stuccoed concrete block masonry with flat
roof on front section. Rear addition is concrete block masonry cov-
ered with vertical boards. Plastered interior walls. Exposed beam
ceiling in front section. Plastered ceiling in rear section. Gabled
wood shingle roof on rear addition. Front section has central heat
and air, rear section utilizes window units. Floor in front section is
concrete tabby, floor in rear section is plain concrete.
Maintenance Estimate: $460,500-$219/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install directional signage at front door directing patrons to the ei-
ther the north of south side entrance. Install sign at door with direc-
tions on asking for assistance.
2. Investigate possibility of replacing narrow double doors for some-
thing more user friendly and period appropriate. Currently the
doors are not compliant for width and will require someone provid-
ing assistance.
Ceiling 1- No Work Needed Board on purlins
Electrical 1 No Work Needed OK
Exterior 3 Minor Repairs Needed Walls: plaster on masonry and vert. board on board
Fenestration 2 Routine Maintenance Needed Doors: double ladder&board,french 12/12
Fenestration 2 Routine Maintenance Needed Windows: Wood D.H. 12/12
Flooring 2 Routine Maintenance Needed Concrete
HVAC 1- No Work Needed New unit
Hazardous Materials 5 Replacement Asbestos survey by ATS Environmental in November, 1994 revealed as-
bestos present in vinyl-asbestos floor tile and its mastic.
Interior 2 Routine Maintenance Needed Walls: plaster on wood
Plumbing 3 Minor Repairs Needed Three restrooms
Roof 5 Replacement Wood shakes. Deteriorating due to improper material and/or installa-
tion. Total replacement required at next maintenance cycle. Projected
life less than 5 years.
Roof 1- No Work Needed New flat roof.


St. Augustine Facility Assessment Report July 2007 Page 36


St. Augustine Facility Assessment Report July 2007


Page 36







Building 3923-FLORENCIA HOUSE


- Photos


St. Augustine Facility Assessment Report July 2007 Page 37


St. Augustine Facility Assessment Report July 2007


Page 37








Building 3924-SPANISH MILITARY HOSPITAL


Address: 2 Aviles Street


GSF: 3,522


Reconstruction Year: 1965

Use: Minor exhibit, leased office space
Description: One and one/half story stuccoed concrete block ma-
sonry with wooden gable end roof covered with wood shingles.
Roofed loggia along east side of structure. Small one story frame
addition covered with beveled siding on northeast corner. Wood
floors throughout with the exception of the loggia, which is tabby
concrete. Plastered interior walls. Separate electric service and
central HVAC for both floors. Private entrance to second floor.
Maintenance Estimate: $220,000-$62/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install directional signage at door informing patrons about ac-
cess to property.
2. Either ramp north entrance or provide compliant path on the
south side.
Ceiling 2 Routine Maintenance Needed 1st & 2nd floor plaster
Electrical 2 Routine Maintenance Needed 2 receptacle covers missing
Exterior 1- No Work Needed Walls: Plaster on masonry, porch, gable ends clapboard
Exterior 1 No Work Needed Building has new windows.
Fenestration 2 Routine Maintenance Needed Doors: wood panel doors
Fenestration 2 Routine Maintenance Needed Windows: Wood S.H. 9/6
Fire Code 5 Replacement Needs automatic sprinkler system....
Flooring 2 Routine Maintenance Needed 1st & 2nd floor wood
HVAC 2 Routine Maintenance Needed 2 gas furnace systems
Asbestos survey by ATS Environmental in November, 1994 revealed
Hazardous Materials 1- No Work Needed no asbestos present.
Interior 2 Routine Maintenance Needed Walls: 1st & 2nd floor plaster
Plumbing 1 No Work Needed 2 bathrooms
Roof 4- Major Repairs Needed Wood shakes, improperly installed, deteriorating


St. Augustine Facility Assessment Report July 2007 Page 38


St. Augustine Facility Assessment Report July 2007


Page 38







Building 3925-WATSON HOUSE


Address: 206 Charlotte Street


GSF: 2,161


,' Reconstruction Year: 1965

Use: Residential


infill. Gable roof with wood shingles. Lapped siding on exterior
n Description: Two story, post and beam construction with brick
walls. Wood frame porch and balcony on front. Plaster walls and
ceilings. Divided into first and second floor apartments. Full bath
and kitchen in each apartment. Electric service adequate for cur-
rent use. The historical authenticity of this building needs to be
investigated.
Maintenance Estimate: $270,000-$ 125/Sq Ft
COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Provide compliant stair handrails.
2. Install handrails at porch step.
Ceiling 2 Routine Maintenance Needed Plaster & Wood board
Electrical 3 Minor Repairs Needed Main panel off/screws missing
Exterior 4 Major Repairs Needed Walls: Clapboard
Exterior 4- Major Repairs Needed Second floor balcony/stairway needs to be completely replaced.
Exterior 3 Minor Repairs Needed Walls: Plaster on Masonry/painted
Exterior 4 Major Repairs Needed Porches: Wood framing and wood members
Fenestration 2 Routine Maintenance Needed Doors: 6-panel wood doors
Fenestration 2 Routine Maintenance Needed Windows: Wood S.H. 9/6 w/shutters
HVAC 4 Major Repairs Needed 2- gas furnace systems
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 2 Routine Maintenance Needed Walls: Plaster
Interior 3 Minor Repairs Needed Needs major cleanup and disinfecting
Plumbing 1- No Work Needed Upstairs-kitchen, bathroom, w&d
Plumbing 3 Minor Repairs Needed downstairs-kitchen, bathroom, w&d
Roof 5 Replacement Wood shakes. Deteriorating due to improper material and/or installation.
Total replacement required at next maintenance cycle. Projected life less
than 5 years.
Site Features 4- Major Repairs Needed Adjacent site overgrown, rat-infested. Need major cleanup.


F''_q


St. Augustine Facility Assessment Report July 2007 Page 39


St. Augustine Facility Assessment Report July 2007


Page 39








Building 3926-SALCEDO KITCHEN


Address: 42 1/2 St. George Street


GSF: 563


Reconstruction Year: 1962

Use: Bakery
Description: One story coquina masonry building with north/
south shingled gable roof. Open porch (loggia) across east side.
Masonry oven and fireplace in south wall. Floor is masonry tabby.
Maintenance Estimate: $52,750-$94/Sq Ft


St. Augustine Facility Assessment Report July 2007 Page 40


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Replace wooden sill ramp at kitchen front door.
2. Provide access to picnic tables. All picnic tables should be accessible
but at least one should have access. Currently there is a 3 to 4 inch
drop off from sidewalk to natural surface picnic area.
3. Install directional signage at stepped access at Whetstone Choco-
lates directing patrons to accessible entrance.
4. Install directional signage at gate notifying patrons that the gate
entrance provides access to kitchen and chocolate shop.
Ceiling 1- No Work Needed Lath on Purlins
Electrical 2 Routine Maintenance Needed 2- 4" boxes missing covers
Exterior 2 Routine Maintenance Needed Walls: Plaster on masonry
Fenestration 2 Routine Maintenance Needed Doors: board on cross buck, Windows: Wood D.H. 6/6
Flooring 2 Routine Maintenance Needed concrete
HVAC 1- No Work Needed None
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed no
asbestos present.
Interior 2 Routine Maintenance Needed Walls: Plaster on masonry
Plumbing 1 No Work Needed None
Wood shakes. Deteriorating due to improper material and/or installa-
tion. Total replacement required at next maintenance cycle. Projected
Roof 4 Major Repairs Needed life less than 10 years.


St. Augustine Facility Assessment Report July 2007


Page 40








Building 3927-SALCEDO HOUSE

Address: 42 St. George Street

h ~Reconstruction Year: 1962


GSF: 2,191


Use: Retail first floor, Residential second floor
Description: Two story coquina masonry with pigmented
stucco. One story wood frame addition covered with beveled sid-
ing to the west. Exposed beam ceiling in first floor of masonry
section. Plaster ceiling on second floor. Interior walls plastered.
E/W gable roof with wood shingles. First floor finish is tabby ma-
sonry, second floor is wood.
Maintenance Estimate: $274,000-$ 125/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Replace wooden sill ramp at front door (install ramped access
along the entire section of the front door patio).
2. Install directional signage at stepped entrance off St. George
and Gated entrance off St. George. (same comment for Sal-
cedo Kitchen)
Ceiling 3 Minor Repairs Needed 2nd floor Plaster cracks living room & bedroom
Ceiling 2 Routine Maintenance Needed 1st floor Plaster
Electrical 3 Minor Repairs Needed no GFI at sink,2" PVC to slab not in coupling
Exterior 2 Routine Maintenance Needed Walls: plaster on masonry
Fenestration 2 Routine Maintenance Needed Doors: Wood doors, Windows: Wood S.H. 12/12
Fire Code 3 Minor Repairs Needed Electrical meter at sidewalk a fire hazard.
Flooring 2 Routine Maintenance Needed 2nd floor wood
Flooring 2 Routine Maintenance Needed 1st floor concrete
HVAC 2 Routine Maintenance Needed 1 window air conditioner, 2 straight cool systems
Hazardous Materials 1 No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed
no asbestos present.
Interior 4- Major Repairs Needed Walls: 2nd floor Plaster water dam. around windows
Interior 2 Routine Maintenance Needed Walls:lst floor plaster
Plumbing 2- Routine Maintenance Needed 2nd floor bath & kit.
Plumbing 1- No Work Needed 1st floor bath & kit.
Roof 5 Replacement Wood shakes
Roof 5 Replacement Porch framing, plywood ice & water shield
Roof 1- No Work Needed New roof on porch in 2007.


St. Augustine Facility Assessment Report July 2007 Page 41


St. Augustine Facility Assessment Report July 2007


Page 41







Building 3927-SALCEDO HOUSE-Photos



.n; n |


St. Augustine Facility Assessment Report July 2007 Page 42


St. Augustine Facility Assessment Report July 2007


Page 42








Building 3928-GONZALEZ RESTROOMS

A Address: 35 1/2 St. George Street

Construction Year: 1983

Use: Visitor Rest Area


Description: This rest room was constructed under the aus-
pices of the Historic St. Augustine Preservation Board in 1982 to
serve the living history museum it had recently developed in
Block 12.
Maintenance Estimate: $24,000-$ 132/Sq Ft


COMPONENT RATING COMMENTS
ADA 4- Major Repairs Needed Recommendations:
1. Provide compliant path of travel from Gonzalez house and sur-
rounding natural path areas.
2. Because the public restrooms are limited in the area, these
restrooms should be fully compliant.
3. Add rear handrails and pad exposed pipes and trap (men and
women rooms). Both sinks are noncompliant due to rim height
(36.5 inches).
4. This area would benefit from a family restroom. Investigate
the possibility of installing an addition to the existing Gonzalez
restroom.
5. Grade surrounding surface to provide access to the restrooms.
Ceiling 1- No Work Needed plaster
Electrical 1- No Work Needed OK
Exterior 3 Minor Repairs Needed Walls: Board on board
Exterior 4 Major Repairs Needed Siding needs repair
Fenestration 3 Minor Repairs Needed Doors: Board on Cross-buckoard, hollow core
Flooring 1- No Work Needed concrete & tile
HVAC 1- No Work Needed None
Hazardous Materials 0 Not Surveyed There was no data on asbestos survey for this building.
Interior 2 Routine Maintenance Needed Walls: tile & plaster
Plumbing 3 Minor Repairs Needed 2 Restrooms & water cooler
Roof 5 Replacement Wood shakes. Deteriorating due to improper material and/or in-
stallation. Total replacement required at next maintenance cycle.
Projected life less than 5 years.













St. ugusineFaciity ssesmen Reort Jul 207 Pae 4


GSF: 182


St. Augustine Facility Assessment Report July 2007


Page 43







Building 3928-GONZALEZ RESTROOMS-Photos


St. Augustine Facility Assessment Report July 2007 Page 44


St. Augustine Facility Assessment Report July 2007


Page 44








Building 3929-SIMS HOUSE

Address: 12 Cuna Street

Reconstruction Year: 1964

Use: Retail


I *~- I


1.1


Description: The main building is a one-story, L shaped frame
with lapped siding. Gable end roof with split wood shingle roof.
Plastered walls and ceiling, wood floors. The outbuilding is wood
framed, covered with beveled siding. The roof is gabled on one
end and hipped on the other. It is covered with wood shingles.
Central HVAC system in main building.
Maintenance Estimate: $125,500-$156/Sq Ft


St. Augustine Facility Assessment Report July 2007 Page 45


GSF: 802


- f "
-1 -


COMPONENT RATING COMMENTS
ADA 4- Major Repairs Needed Recommendations:
1. Provide access to the north side entrance. Install approxi-
mately 100 ft of sidewalk to north entrance (connect from ex-
isting sidewalk running east to west from main road (A1A) to
restaurant).
2. Install platform and ramp at north entrance.

Ceiling 1- No Work Needed Plaster
Electrical 1- No Work Needed OK
Exterior 2 Routine Maintenance Needed Walls: Clapboard
Exterior 1 No Work Needed recently painted
Fenestration 2 Routine Maintenance Needed Doors: Exterior 6-panel wood door, Windows: Wood D.H. 12/12
Flooring 2 Routine Maintenance Needed Wood board
HVAC 4 Major Repairs Needed Straight cool central A/C
Hazardous Materials 1- No Work Needed Asbestos survey by ATS Environmental in November, 1994 revealed
no asbestos present.
Interior 2 Routine Maintenance Needed Walls: Plaster
Plumbing 1- No Work Needed None
Roof 5 Replacement Wood shakes. Deteriorating due to improper material and/or in-
stallation. Total replacement required at next maintenance cycle.
Projected life less than 5 years.


_
~~-_


I I rlilis- I


:..I~-


St. Augustine Facility Assessment Report July 2007


Page 45








Building 3930-SIMS OUTBUILDING

L'" M Address: 12 Cuna Street


GSF: 173


Reconstruction Year: 1964

Use: Storage
Description: There is a single restroom in outbuilding.
Maintenance Estimate: $22,000-$ 127/Sq Ft


COMPONENT RATING COMMENTS
ADA 1- No Work Needed Storage facility and no work needed.
Ceiling 1- No Work Needed Plaster
Exterior 5 Replacement Walls:Clapboard
Fenestration 1- No Work Needed Doors:6-panel wood
Fenestration 1- No Work Needed Windows: 6 light sliding
Flooring 1 No Work Needed Painted plywood
Interior 1- No Work Needed Walls: Plaster
Plumbing 2- Routine Maintenance Needed 2 restrooms
Plumbing 2 Routine Maintenance Needed water cooler
Roof 5 Replacement Wood shakes. Deteriorating due to improper material and/or in-
stallation. Total replacement required at next maintenance cycle.
Projected life less than 5 years.



















SA iFlA sJ 2


St. Augustine Facility Assessment Report July 2007


Page 46








Building 393 I-OLD BLACKSMITH SHOP


Address: 26 Charlotte Street


GSF: 363


Reconstruction Year: 1966

Use: Retail
Description: Post and beam frame with board and batten sid-
ing. Gable roof covered with wood shingles. Shed roofed addi-
tion to south. Wood block floor. No other interior finish.
Maintenance Estimate: $117,250-$323/Sq Ft


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Have city install curb ramp to sidewalk in order to access store.
2. Speak with city about pedestrian access to the shops along the
eastern leg of Cuna St. The only access is in the street which
has a brick paver surface.
Ceiling 4- Major Repairs Needed timber and sheathing
Ceiling 3 Minor Repairs Needed Gyp board (kit.)
Electrical 1- No Work Needed OK
Exterior 3 Minor Repairs Needed Siding needs partial replacement
Exterior 5 Replacement Walls: Board & Batten
Fenestration 5 Replacement Windows: Wood Shutters cross buck & board
Fenestration 3 Minor Repairs Needed Doors: board and ladder
Flooring 2- Routine Maintenance Needed Wood (brick)
Flooring 2 Routine Maintenance Needed Board flooring (kit.)
HVAC 2 Routine Maintenance Needed Window A/C
Asbestos survey by ATS Environmental in November, 1994 revealed
Hazardous Materials 1 No Work Needed no asbestos present.
Interior 5 Replacement Walls: Board (must be removed w/outside wall)
Plumbing 2 Routine Maintenance Needed One sink
Roof 5 Replacement Wood shakes
Roof 4 Major Repairs Needed Rear portion new, remainder needs replacement


St. Augustine Facility Assessment Report July 2007 Page 47


St. Augustine Facility Assessment Report July 2007


Page 47







Building 393 I-OLD BLACKSMITH SHOP-Photos


I 'w.


-I. I'c-


St. Augustine Facility Assessment Report July 2007 Page 48


St. Augustine Facility Assessment Report July 2007


Page 48








Building 3932-HARNESS SHOP


Address: 17 Cuna Street


GSF: 566


Reconstruction Year: 1967

Use: Rental, retail
Description: Concrete block walls with applied
wood siding. Hipped wood shingle roof with shed
roof on street front. Concrete floor.
Maintenance Estimate: $106,000-$ 187/Sq Ft


St. Augustine Facility Assessment Report July 2007 Page 49


COMPONENT RATING COMMENTS
ADA 3 Minor Repairs Needed Recommendations:
1. Install curb ramp and sidewalk access.
2. Increase the width of the brick paver walkway to store en-
trance.
3. Install compliant sill access (2 inch rise).
Ceiling 2 Routine Maintenance Needed Gyp Board on joists
Electrical 2 Routine Maintenance Needed OK
Exterior 4- Major Repairs Needed Walls: Board & Batten
Fenestration 2 Routine Maintenance Needed Windows: Wood D.H. 6/6
Fenestration 3 Minor Repairs Needed Doors:Board & Batten
Flooring 1- No Work Needed Int.- Wood t&g oak
Flooring 2 Routine Maintenance Needed Ext.- End cut Wood brick
HVAC 2 Routine Maintenance Needed mini split system
Hazardous Materials 4 Major Repairs Needed Asbestos survey by ATS Environmental in November, 1994 revealed
asbestos present in gray cementitious roofing material.
Interior 2 Routine Maintenance Needed Walls: 1x3 T&G vert. Board
Plumbing 1- No Work Needed None
Roof 5 Replacement leaks over porch, needs repair
Roof 5 Replacement Wood shakes(can be replaced with metal roof). Deteriorating due
to improper material and/or installation. Total replacement re-
quired at next maintenance cycle. Projected life less than 5 years.


St. Augustine Facility Assessment Report July 2007


Page 49








Building 3933-PUBLIC RESTROOMS


Address: 40 St. George Street


GSF: 624


Construction Year: 1967

Use: Public Restrooms
Description: The men's and women's rest rooms are di-
vided by a small storage room. Handicap accessible.
Maintenance Estimate: $78,000-$ 125/Sq Ft


COMPONENT RATING COMMENTS
ADA 4- Major Repairs Needed Recommendations:
1. Install compliant handrails at ramp.
2. Install side handrail at both the men and women restroom.
Currently there is a left side and rear rail. Install right side rail.
3. The area is lacking in accessible restrooms. Advise that both
the men's and women's room be brought up to Florida Building
Code Guidelines. Or, install a family style accessible restroom.
4. Install directional signage on wall of exterior wall (on St.
George St.) that notifies visitors about the restrooms and ac-
cess for the bakery and chocolate shop.
Ceiling 1 No Work Needed plaster
Electrical 2- Routine Maintenance Needed OK
Exterior 3 Minor Repairs Needed Walls: Plaster on masonry
Fenestration 1- No Work Needed Doors: S.C. Wood Doors
Flooring 1 No Work Needed Ext.-concrete, Int.- tile (glazed quarry tile))
HVAC 1 No Work Needed None
Asbestos survey by ATS Environmental in November, 1994 revealed
Hazardous Materials 1 No Work Needed no asbestos present.
Interior 2 Routine Maintenance Needed Walls: tile & plaster
Plumbing 2 Routine Maintenance Needed 2 Restrooms & water cooler
Roof 5 Replacement Built-up


St. Augustine Facility Assessment Report July 2007 Page 50


St. Augustine Facility Assessment Report July 2007


Page 50























Commercial
Real Estate (16 bldgs)

Residential
Real Estate (7 units)

Parking Lots (9)


- Sala Room


Museum
Gift Store

- Gov't House
Gift Store

- Taberna del Gallo
(Tavern)
Gov't House
Brochure Rack


Colonial
Spanish Quarters

Gov't House
Museum

- Summer Camp (new)


- Bookstore


Menendez
Festival Sponsors

Menendez
Festival Sales

-Other Events
(Sponsors and Sales)


Heritage Tourism





Dr. Kenneth J. Osfield
EH&S
ADA Compliance Office
University of Florida
Gainesville, FL 32611-5055

ADA Review





State-Owned Buildings in

St. Augustine


ADA Review St. Augustine, FL


Review Dates:


July 5, 2007
July 19, 2007















C aveat ........................................................................................................... 6

H historic D resignation .........................................................................................6

Project D description ...........................................................................................7

Introduction.................................................................................................. 8

Historic Preservation.................................................................................. 8

University of Florida's Obligations ........................................... .......... ... 9

Feasibility of Completing Recommendations............ ........................10

Designation of Appropriate Staff to Handle ADA & 504 Issues .............10

A D A O office ..... ................................................ ...... .... .... .......... 10

Project Overview....................................................................................... 10

Facility Overview....................................................................................... 11

F a c ility A c c e s s ................... ................ .... ............ ... ...... ................. 1 1

Staff Commitment .............................................................................. 11

Exterior Facility Review ......................................................................... 11

P parking A access ....... .. ...... .. ............................................. ...... ... 11

Sidewalk Access ......... ................................... ....................... 12

Natural Paths (crushed stone) Access ........................... .......... 12

Drainage Grates Located in Sidewalks ............................................. 13

Curb Ramp Access.................................... ................. 13

Exterior Directional Signage Overview............................................ 14

Picnic Area Accessibility.................................................................. 14

Automatic Door Operating Devices ................... ...... ........... 14

Ramped Facility Entrances.......................................... .................. 15

Vertical Access.......................................................................................... 16

Exterior Stair Access ................. .............................................. 16

Interior Facility Review ........................................................................................17












R estroom S ignage ................................................. .................. 17

D oor H and le ................ .................. ........................ .......... .... .. 17

Restroom Accessibility ............. .... ........................ ................ 17

Historic Facility Policy Development ............................................ .... 18

General Statement on Accessibility................................... 18

Educational Areas Access Policy ................... ..... ............ 18

W orld W ide W eb Access Policy ............................. .................. 18

Parking Lot Access Policy .......................................... ................ 18

Facility-Wide Committee Review Process ....................................... 19

R eferences ........ .............. .... ......................................................... 20



Appendices A-C

Appendix A Facility Inventory with building-by-building deficiencies

Appendix B Florida Building Code, Chapter 11 (Accessibililty) Sections 11-4.1.7(2)
& (3) Accessible buildings: Historic Preservation

Section 11-4.1.7(2)(a)- Alterations to qualified hsitoric buildings and facilities subj ect
to Section 106 of the National Historic Preservation Act

Section 11-4.1.7(2)(b) Alterations to qualified historic buildings and facilities not
subject to Section 106 of the National Historic Preservation Act

Section 11-4.1.7(3) Historic preservation; Minimum requirements

Appendix C (1) February 9, 2007 report compiled by Dr. William R. Adams, Director -
Department of Heritage Tourism "Description and Photographs of the State-Owned
Buildings in St. Augustine Managed by the City of St. Augustine" and (2) a report by the
Special Task Force on St. Augustine State-Owned Historic Properties dated December 1,
2006, titled "State-Owned Historic Properties and Programs in St. Augustine, Florida:
Recommendations".



















































































4









State-Owned Buildings in
St Augustine
ADA Review











Caveat


This report is submitted as a result of the potential transfer of state-owned
buildings in St. Augustine, managed by the City of St. Augustine to the
University of Florida. This is an independent report requested for proactive
reasons and not the result of any action against the State of Florida, the City of
St. Augustine or the University of Florida. As such, it is a tool to be used by
the University of Florida to provide options for improved access to the
transferred facilities. The comments and suggestions contained within are
based on the guidelines in the Rehabilitation Act of 1973, Section 504 (Public
Law 93-112, as amended, 34 CFR part 104), the Americans with Disabilities
Act of 1990 (Public Law 101-336, 42 U.S.C., 12101-12132), and the Florida
Building Code (FBC, Chapter 11).


Historic Designation

There is some question as to which buildings are designated Historic under
Section 106 of the National Historic Preservation Act. The appropriate
University group will need to make the final determination as to which
buildings are covered under Section 106. For purposes of this report only 7
structures are considered historic:

1. Government House c. 1710 (restoration and reconstruction)
2. De Mesa Sanchez House ca. 1760 (expanded in 1760's & ca. 1830)
3. Arrivas House c. 1740
4. Parades Dodge House ca. 1808
5. Cerveau House ca. 1885
6. Hass House ca. 1880
7. Joaneda House ca. 1806

Recommendation:
1. Appropriate University committee should determine which buildings
come under Section 106 of the National Historic Preservation Act.











Project Description


Dr. Kenneth Osfield, ADA Coordinator for the University of Florida,
conducted an ADA review of the facilities on July 5 and July 19, 2007. The
review included:
An ADA review of the State-owned buildings under the
management of the City of St. Augustine. (Refer to Appendix
A for a complete list of buildings.) A total of 34 buildings are
listed in the inventory.

Historic facilities -7 structures.

Reconstructed facilities -27 structures (1963-1966; 1976-83)

The audit for each building included:

Review exterior access to each facility. Path of travel to
and from parking and bus stops to the facility.

Review exterior entry points and evaluate how patrons are
informed of which entrances are accessible.

Interior review the review will included all public areas
(restrooms, meeting space, exhibition space, retail, housing,
educational)

The report includes a narrative report and a building
specific report with building-by-building deficiencies.

The audit will not include

Any review of private offices, equipment rooms, and
other non-public space.

The report will not include any cost estimates for
correcting the non-compliant items.

The following report is based upon an on-site review of the State-owned
facilities in St. Augustine under the management of the City of St. Augustine
conducted by Dr. Kenneth J. Osfield, University of Florida ADA Compliance.
Prior to the onsite review two reports were reviewed that provided valuable
information about the properties reviewed. Refer to Appendices C for
information about the reports.













Introduction


State and local governments have been required since 1973, under the
Rehabilitation Act of 1973 (Section 504) to ensure that


I No qualifiedperson with a disability shall, on the basis of the disability, be
excluded from participation in, be denied the benefits of or otherwise be
subjected to discrimination under program or activity which receives or benefits
from Federal financial assistance.


Prior to 1990, Section 504 was a piece of legislation that did not fulfill all the
expectations of people with disabilities and those that developed the
legislation. It was not until 1990, when the Americans with Disabilities Act
was signed, that people with disabilities began to make gains in accessing
programs and services, and facilities operated and maintained by state and
local governments.

Seventeen years after the Americans with Disabilities Act and thirty-four
years after the Rehabilitation Act (Section 504) were signed there is still
considerable discussion about what the legal requirements are for state and
local governmental agencies under both ADA and 504. Some agencies see it
as a moral more than a legal responsibility and provide services to patrons
with no thought of cost, while other agencies fight the smallest cost using the
defense that it is not their responsibility.

The State of Florida has made a moral and financial commitment to provide
access to programs and services by individuals with disabilities and with the
change in management for the properties the issue of ADA needs to be
addressed by the State, the City of St. Augustine, and the University of
Florida. On campus there are many departments that will need to review
various aspects of the properties in question and the ADA issues are but one
area that will require attention.


Historic Preservation

Under section 11-4.1.7 (Accessible buildings: Historic preservation) of the
Florida Building Code the general rule when considering ADA access:











Alterations to a qualified historic building or facility shall comply
ii ilh Section 11-4.1.6 (Accessible buildings: Alterations), the
applicable technical specifications of Section 11-4.2 through
Section 11-4.35 and the applicable special application Section 11-
5 through Section 11-10 unless it is determined in accordance i i/h
the procedures in Section 11-4.1.7(2) that compliance i i/h the
requirements for accessible routes (exterior and interior), ramps,
entrances, or toilets would threaten or destroy the historic
significance of the building or facility in which case the alternative
requirements in Section 11-4.1.7(3) may be usedfor the feature.
(For the full-titles of the following sections refer to Appendices B
11-4.1. 7(2) and 11-4.1.7(3).

It should be noted that the appropriate University agency should
determine which facilities come under Section 106 of the National
Historic Preservation Act.


University of Florida's Obligations

For a public institution such as the University of Florida, it is clear that it is
covered under the Americans with Disabilities Act and the Rehabilitation Act
of 1973, as amended (Section 504). Together, the two pieces of legislation
provide wide sweeping protection to students, staff, faculty, visitors, and
ultimately to anyone taking part in any program, service or activity sponsored
by the University.

The University of Florida, under the ADA, is subject to all Titles of the ADA,
however, the major responsibilities come under Title I (employment), Title II
(state and local government), and Title IV (communications). It is also
subject to the provisions within Section 504 of the Rehabilitation Act of 1973
for its treatment of students, staff, faculty and visitors.

Within the guidelines of Section 504 [34 CFR 104.7(a)(1980)] and ADA an
employer (UF) is required to coordinate the institutions compliance efforts.
How that is achieved is up to the discretion of the institution.

As a title II entity under the ADA and a recognized 504 entity (funded by
federal funds) the University is required to provide access to all programs and
services. How does this apply to the historic St. Augustine properties?
Because many of the facilities are historic it still needs to be determined
which facilities can be modified and how. At the least alternate access will
need to be provided as specified in chapter 11 of the Florida Building Code
(11-4.1.7).











Feasibility of Completing Recommendations

The recommendations within this report and the facility review report for the
most part are within reason. The majority of facility issues are minor (ramps,
directional signage, handrails, policy development). Some of the issues are
outside the jurisdiction of the University and will require the City taking the
lead (parking access, sidewalk access to and from parking and bus stops to the
historic district, sidewalk curb ramps, drainage grates within paths of travel).
Overall, the recommendations are all attainable as long as funding is provided.


Designation of Appropriate Staff to Handle ADA & 504 Issues

The University has professional staff in place with very specific
responsibilities under ADA and 504. The UF ADA Office is responsible for
all ADA facility reviews, manages the complaint process (visitors, students,
faculty and staff), employee issues, compliance issues, and ADA facility
compliance. UF has had an ADA coordinator since 1989, one year prior to
the ADA being signed.

ADA Office
The ADA coordinator at UF is the person designated as the ADA Compliance
Officer and handles all issues related to compliance and facility access.


Project Overview

As a result of the recommendation that The University of Florida take over
managerial responsibilities for the State-owned properties in St. Augustine
that are under the management of the City of St. Augustine, the UF ADA
coordinator notified university administration that a review would need to be
conducted in order to obtain a clear picture of the properties and what may or
may not be needed to bring the facilities into compliance with both Section
504 of the Rehabilitation Act of 1973 and the Americans with Disabilities Act
(ADA). The ADA Office made this request not as a result of any pending
complaints but instead in a proactive manner to ensure that the University
facilities are compliant.

The areas of review are specified in the Project Description section on page 7.
The review will focus on facility compliance only.

Facility review The facility review was completed in 2 phases, with phase-I
taking place on July 5, 2007, and the second review taking place on July 19,
2007.











Facility Overview


The following sections are an overview of various aspects of the external
accessibility and the interior facility conditions. A facility-by-facility review
can be found in Appendices A. The building deficiencies have also been
entered into the Facilities Planning STARS Building Assessment module.

Facility Access
The State-owned facilities under review vary in age significantly with at least
7 considered historic (c. 1710 to 1885) and 25 other structures built or
reconstructed from 1962 to 1983.

The use varies from educational facilities, administration and office, retail
rental stores and living areas (apartments). This report provides a building by
building review for each facility.

Due to the age of the area involved there are inherent problems that will
impact accessibility issues.

With the exception of the Government House with its freight elevator none of
the other facilities have any ADA vertical access (stairs only). In the case of
the Government House, vertical access could be provided using the current
freight elevator (alternate access), however it does not provide access to all
sections of the upper level.

Street access becomes problematic in that many of the adjoining streets and
sidewalks are very narrow which doesn't allow for a continuous safe and
protected path of travel. Once access to the old section is attained access is
somewhat easier in that some of the areas are pedestrian traffic only and the
cars on the areas with vehicle access are held to a 5 mph. Many of the street
related access issues need to be discussed with the City of St. Augustine (side
walks, curb ramp, pedestrian cross walks, parking, etc...).

Staff Commitment
The university staff are very involved with the University's commitment to
students, staff and visitors with disabilities and will continue to provide
consulting services to the UF Historic committee, City of St. Augustine and
others.


Exterior Facility Review

Parking Access
One of the first areas that visitors, students and staff are exposed to at any
tourist area is the availability of parking. As such, it is a very important











component to any agency master plan and deserves very close attention and
constant review. The buildings within the scope of this review are contained
within a pedestrian area and parking is very limited to a few areas. The
majority of parking is outside the scope of the properties in question as they
are provided by the City (Garage) or Federal Government (Fort). There is a
parking garage and surface lot adjacent to the area in question. Currently all
parking associated with the properties in question are reserved for store
owners, apartment renters.

Recommendations:

2. Meet with both the City and Federal agencies that oversee the tourist
parking in the area to ensure the spaces are compliant for size, number and
provide safe paths of travel to and from sidewalks.

Sidewalk Access
Overall, the sidewalks to and from the parking lots, bus stops and to and from
historic buildings vary in terms of access. Many of the sidewalks serving the
historic district are narrow with very few compliant curb ramps. However,
one of the main streets (St. George) has been converted into a pedestrian only
zone so access is spacious and accommodating. The structures off the street
however have inherent problems due to the elevation differences of the street
and the shops. Many of the shops are 10-12 inches above grade thus making
code access currently non-existent. Streets such as Cuna Street also present
problems due to lack of sidewalks, curb access and poor walking surface on
street surface (brick pavers).

Recommendation:

3. Meet with City of St. Augustine to discuss compliant sidewalk access in
and around the historic district.

Natural Path (Crushed Stone) Walkway Access
Many of the facilities within the review are connected to one another through
the use of crushed rock/mulch (limestone, bark mulch, etc...) walkways.
These areas need to be reviewed and regularly maintained. During the time of
this review many of the areas appear to have not been maintained. For
example the crushed rock path to the Gonzalez restrooms are at least 3-4
inches lower than the concrete patio that provides access and thus the
restrooms (though marked accessible) are in fact not accessible.











Recommendation:


4. Staff on both locations should meet to discuss how they want to provide
access in the future. Should impervious surfaces be used or do we
continue with natural surfaces already in place.

Drainage Grates Located in Sidewalks (issue for the City of St. Augustine)
For the most part there are at least 3 drainage grates located within walking
surfaces in the areas reviewed. Those grates that are not compliant with 11-
4.5.4 are under the City's jurisdiction and will need to be reviewed.

Any grate within a walking surface shall comply with 11-4.5.4 ("if gratings
are located in walking surfaces, then they shall have spaces no greater than 12
inch wide in one direction [refer to figure 8g in the FBC]. If gratings have
elongated openings, then they shall be placed so that the long dimension is
perpendicular to the dominant direction of traffic" [refer to figure 8h in the
FBC]).

Recommendation:

5. Meet with City of St. Augustine to discuss grates within pedestrian
pathways and develop plan to upgrade non-compliant grates. Location of
grates in question:

a. St. George and Treasury Streets large street rated grate that is
within the pedestrian area and is non-compliant due to size of
openings.

b. St. George and Hypolita Streets large street rated grate that is
within the pedestrian area and is non-compliant due to size of
openings.

c. Tilley Hat shop there is a grate in front of the Tilley hat shop that
has openings that are 1 inch wide.

Curb Ramp Access (issue for the City of St. Augustine)
Curb ramps need to be reviewed by the City of St. Augustine and corrections
and upgrades completed as necessary. Please note, that because the FDOT
and the ADAAG provide a greater degree of accessibility they override the
FBC in the case of 11-4.29.2. In any case any system other than truncated
domes are noncompliant, especially any system that uses grooves of any sort
cut or fixed into the surface (saw cut, diamond mess, etc).

The appropriate agencies should meet as soon as possible to discuss a City
standard for the detectable warning system and curb ramps in general. It is
recommended that a representative from the City Facilities Planning Office,











City Code Compliance Office, and UF ADA Office meet to discuss FDOT,
FBC and ADAAG regulations for curb ramps.

Recommendation:

6. Meet with City of St. Augustine to discuss compliant curb ramp access.

Exterior Directional Signage Overview
Many of the facility entrances (retail areas) are not accessible and in few
instances there is alternate access provided. The alternate access is not always
obvious.

Signs should be installed that would make navigation in and around the
historic district easier for visitors and town residents with mobility related
disabilities.

Recommendation:

7. At all noncompliant pedestrian facility entrances, install directional sign
that will inform patrons where the nearest accessible entrance is located.
The sign should include the wheelchair pictogram and the text "wheelchair
access" along with an arrow leading to the direction of the nearest
entrance. The signs need to be very visible with a functional and clear
message. When access is not available install sign informing patrons what
the next step is. For programs, some sort of alternate access should be
provided (written materials, audio materials, etc.).

Picnic Area Accessibility
For those areas with kitchen service and subsequent picnic table areas there
should be a compliant path of travel to the kitchen area and the surrounding
picnic tables. Tables should meet specifications in 11-4.32 (tables):

Recommendations:

8. In each separate picnic location provide a compliant path of travel to a
minimum of one picnic table (preferably all).

9. Install at least one table in each area that will allow for wheelchair seating.
The best tables to use are those with fixed benches and open ends that
extend at least 19 inches and have a minimum of 30 inches between the
two benches (these tables allow for two wheelchair users, one on each
end). Accessible picnic tables should comply with 11-4.32 of the FBC.
There are other designs, which remove one of the fixed seats, but these
designs then limit the number of people that can use the table.











Automatic Door Operating Devices at Main Building Entrances
(Government House only)
There is no requirement under either the FBC or the ADAAG to provide
automatic doors in any facility. The only time automatic doors are required
are when the doors cannot be adjusted to the correct manual opening force
requirements (8.51bf. for exterior doors and 51bf for interior doors). UF
Construction Standards call for automatic door opening devices at all main
entrances. Only one of the properties would fall under this requirement
(Government House).

Recommendation:

10. Install auto door at east side ramp entrance of the Government House.

Ramped Facility Entrances
This is one of the weakest areas within the facilities under review. Many of
the existing ramps are noncompliant, in poor shape or non-existent. Those
areas with specific ramp deficiencies have been addressed individually within
the building review sections of this report and Facilities STARS. Many of the
retail areas have no ramped access. Overall the areas of concern are:

Recommendations:

11. Educational facilities wooden ramps installed must comply with all
aspects of the FBC, including section 11-4.8 (ramps). Ramps shall
comply with slope and rise (11-4.8.2), landings (11-4.8.4) and handrails
(11-4.8.5). Currently, both new and old ramps at many of the areas have
many noncompliant features. Install compliant ramps (refer to specific
building comments).

12. Retail areas As a result of the pedestrian zone at St. George Street there
is an opportunity to provide ramped access to many of the shops that
currently do not have ADA access. Access should be provided as long as
the historical integrity of the area is not impacted. Install a raised platform
(5 ft. x 5 ft.) at various entrances with a ramp to the platform.

Generally speaking, when ramps are used the slope and rise should be as
gradual as possible with the preference at less than a 1:20 slope. In many
instances this is not possible but it should be the design goal of all projects to
eliminate all sloped surfaces greater than 1:20.











Vertical Access


Exterior Stair Access
The external stairs at many of the buildings are not compliant primarily due to
the lack of handrails. The handrails are noncompliant with many aspects of
11-4.9.4 and 11-4.26. To be compliant handrails must meet the following
code specifications as listed in 11-4.9.4 and figure 39:

Recommendations:

13. Install compliant handrails at all stairs within the facilities under review.

a. Handrails shall be continuous along both sides of stairs. The inside
handrail on switchback or dogleg stairs shall always be continuous.

b. If handrails are not continuous, they shall extend at least 12 inches
beyond the top riser and at least 12 inches plus the width of one
tread beyond the bottom riser. At the top, the extension shall be
parallel with the floor or ground surface. At the bottom, the
handrail shall continue to slope for a distance of the width of one
tread from the bottom riser; the remainder of the extension shall be
horizontal. Handrail extension shall comply with 11-4.4.

c. The clear space between handrails and wall shall be 11/ inches.

d. Gripping surfaces shall be uninterrupted by newel posts, other
construction elements, or obstructions.

e. Top of handrail gripping surfaces shall be mounted between 34
inches and 38 inches above stair nosing.

f. Ends of handrails shall be either rounded or returned smoothly to
floor, wall or post.

g. Handrails shall not rotate within their fittings.

The handrails are also required to be compliant with 11-4.26:

h. The diameter or width of the gripping surfaces of a handrail or
grab bar shall be 114 to 1 /2 inches, or the shape shall provide an
equivalent gripping surface. If handrails or grab bars are mounted
adjacent to a wall, the space between the wall and the grab bar
shall be 1 /2 inches.












Interior Facility Review


Restroom Signage
There are only 3 public restrooms (Government House, Gonzalez Restrooms,
Public restrooms near Salcedo Kitchen) available within the facilities under
review. Accessible restrooms should have the following:

1. Wheelchair and gender specific pictograms installed in the correct location
on the wall adjacent to the latch side of the door and at a mounting height
of 60 inches above the finish floor to the centerline of the sign.

2. Signs should be in Braille and raised letters and pictograms shall have the
equivalent verbal description placed directly below the pictogram. It is
recommended that all pictograms used be raised and tactile.

3. Signs should not be installed on the door. The only sign that should be
located on the door is the decal for an automatic door-opening device
(when available).

4. Directional signage should located around the city informing patrons
where restrooms are located.

Signs need to be consistent and code compliant.

Recommendation:

14. Have UF Physical Plant install new compliant signage. Install directional
signage around facilities that will inform patrons of the location of
restrooms.

Door Handle
Florida Building Code requires that door hardware comply with section 11-
4.13.9 of the FBC. The section states that "handles, pulls, latches, locks, and
other operating devices on accessible doors shall have a shape that is easy to
grasp with one hand and does not require tight grasping, tight pinching, or
twisting of the wrist to operate. Lever-operated mechanisms, push-type
mechanisms, and U-shaped handles are acceptable designs."

All public areas should all have compliant door hardware, no matter the age of
the facility.

Door hardware does not seem to be an issue at the present time.

Restroom Accessibility
Visitors to the area should have access to accessible restrooms. There are
only 3 public restrooms (Government House, Gonzalez Restrooms, Public











restrooms near Salcedo Kitchen) available within the facilities under review.
For specific information about the deficiencies of each restroom refer to
individual facility review documents.

Recommendations:

15. Install family style restrooms in all three areas.


Historic Facility Policy Development

General Statement on Accessibility
When working with disability related issues it is a wise practice to have
reasons and justification for why things are done in a certain way. This way,
if complaints are filed the University does not come off as arbitrary and
capricious in its decisions. It is a wise practice to think ahead and develop and
implement policies that will provide an opportunity for people with
disabilities to have equal access to the programs, services and activities
sponsored by the University. It is always better to be proactive then reactive.
With the development of good, sound policies the disabled community will be
afforded better access and the University will have more consistent and well
thought out responses for its constituents.

Educational Areas Access Policy
It is recommended that the University develop a facility-wide policy that
addresses educational and demonstration access within the properties. The
policy should address overall program and service access, existing educational
space, future space, funding, alternate to those areas that may not currently be
accessible. The committee should also outline the procedures for the
oversight of assuring that all programs and services are accessible, whether
that means upgrading facilities or providing a procedure by which, alternate
access to non-accessible areas is provided. Ultimately the goal is to provide
equal access to all programs, services and activities offered by the University.

World Wide Web Access Policy
Any website design dedicated to the facilities shall comply with ADA
standards for accessibility. Provide accessibility statement on the facilities
under UF's direction.

Parking Lot Access Policy
Usually the first contact anyone will have with an educational program like
the St. Augustine properties is when they try to park their cars. As such, the
first impression is often set before they even get out of their cars and visit or
take part in any activity associated with the program. You can never satisfy











all the people all the time, but with good policies and consistent oversight and
implementation of those policies many problems can be eliminated. Disabled
parking availability is no exception, and the best way to handle the issue is for
the University to constantly review its parking inventory; especially the
placement of disabled parking spaces.

Currently parking is limited within the historic district. All parking within the
facilities in question are reserved for staff and tenants.

Recommendation:

16. Review parking areas within the facilities in question to determine if it is
possible to provided disabled parking spaces.


Facility-Wide Committee Review Process

Facility Design and Development Review Team
One of the most important components of any campus has to be the facility
review process that is in place. I say this, because of the amount of money
that goes into design, development and construction of new facilities. With
that said, it then stands to reason that when mistakes are made in the process,
those mistakes are generally very costly. Costly in that the project opening
can be delayed, and extra funds might be needed to correct the deficiencies
discovered. As a result it is very important to involve as many staff as
possible in the design and review development phase of all construction
projects. The process should be in place for both major projects (over $1
million) and minor projects (under $1 million).

One of the biggest mistakes made in the design and review process is to
assume that the architects, construction managers and various subcontractors
will design, develop and build to code. Even with all the review phases in
place, there are always going to be items that slip by and cause problems
during the review phase of any project. The University should dictate what
they want and expect in their facilities during the design and construction
phases and not leave it to the architect, construction manager and
subcontractors. Those individuals are after all, advisors to the University.
Hence, it is important to have as many people as possible review the design
submittals for all aspects of code compliance and special interest needs. That
review should not only involve the Facilities Planning, Physical Plant, Code
Compliance, and ADA staff but also other key staff involved in issues related
to facilities. In case of ADA compliance the review should also involve
members from the community with disabilities.














References


Equal Employment Opportunity Commission & U.S. Department of Justice
(October 1991), The Americans with Disabilities Act Handbook: Title I & II.

34 CFR 104 (1980)

Public Law 101-336, 42 U.S.C., 1201-12132

Florida Building Code, Chapter 11 Florida Accessibility Code for Building
Construction
































Appendix A


Facility Inventory with building-by-building deficiencies






























Appendix B


Florida Building Code, Chapter 11 (Accessibililty) Sections 11-4.1.7(2) & (3) Accessible buildings:
Historic Preservation

Section 11-4.1.7(2)(a)- Alterations to qualified hsitoric buildings and facilities subject to Section 106
of the National Historic Preservation Act

Section 11-4.1.7(2)(b) Alterations to qualified historic buildings and facilities not subject to Section
106 of the National Historic Preservation Act

Section 11-4.1.7(3) Historic preservation; Minimum requirements



(next page is Appendix C)




























Appendix C


Reports provided to review team prior to the onsite audit.

February 9, 2007 report compiled by Dr. William R. Adams, Director Department of
Heritage Tourism "Description and Photographs of the State-Owned Buildings in St.
Augustine Managed by the City of St. Augustine".

December 1, 2006 report by the Special Task Force on St. Augustine State-Owned