PAGE 1

FCS3261 Energy Ecient Homes: Ceiling Fans 1 Hyun-Jeong Lee, Kathleen C. Ruppert, Wendell A. Porter, and Randall A. Cantrell 2 1. This document is FCS3261, one of the Energy Ecient Homes series of the Department of Family, Youth, and Community Sciences, UF/IFAS Extension. Original publication date April 2008. Revised July 2015. This material was initially prepared with the support of the Department of Environmental Protection, Florida Energy Oce, which is now the Oce of Energy, Florida Department of Agriculture and Consumer Services. The revised versions were completed with the support of the Florida Energy Systems Consortium ( http://oridaconserves.org ). Any opinions, ndings, conclusions, or recommendations expressed herein are those of the author(s) and do not necessarily reect the views of the sponsoring organizations. Visit the EDIS website at http://edis.ifas.u.edu 2. Hyun-Jeong Lee, former assistant professor, Department of Family, Youth, and Community Sciences; Kathleen C. Ruppert, Extension scientist, Program for Resource Ecient Communities; Wendell A. Porter, lecturer and P.E., Department of Agricultural and Biological Engineering; and Randall A. Cantrell, assistant professor, Department of Family, Youth, and Community Sciences; UF/IFAS Extension, Gainesville, FL 32611. The Institute of Food and Agricultural Sciences (IFAS) is an Equal Opportunity Institution authorized to provide research, educational information and other services only to individuals and institutions that function with non-discrimination with respect to race, creed, color, religion, age, disability, sex, sexual orientation, marital status, national origin, political opinions or aliations. For more information on obtaining other UF/IFAS Extension publications, contact your countys UF/IFAS Extension oce. U.S. Department of Agriculture, UF/IFAS Extension Service, University of Florida, IFAS, Florida A & M University Cooperative Extension Program, and Boards of County Commissioners Cooperating. Nick T. Place, dean for UF/IFAS Extension. Quick Facts Ceiling fans are appliances wrapped decoratively with unique housings in a variety of nishes, and they oen feature furniture-grade blades and accessories. In the summer, use of a ceiling fan allows for raising the homes thermostat setting by 4F without feeling a dierence in comfort. Even in the winter, most ceiling fans help when operated in the reverse direction by forcing warm air near the ceiling down into your occupied area. Ceiling fan/light combo kits that have earned the ENERGY STAR label are about 60% more ecient than conventional fan/light units. Terms to Help You Get Started Downrod: Extension rod that allows you to set the fan at the proper height from your ceiling for optimum performance CFM: Cubic Feet per Minute CFM/watt: Cubic Feet per Minute/watt measures air ow eciency for ceiling fans; the higher the number, the more ecient the unit. UL: Underwriters Laboratories Can ceiling fans lower my utility bill? One of the myths about ceiling fans is that they lower the temperature in a room. Actually, ceiling fans do not lower room temperature. However, they do create a breeze, making room occupants feel cooler and more comfortable. When a ceiling fan is operating, you can usually raise the thermostat setting by up to four degrees during the cooling season with no reduction in comfort. Increasing the room temperature by even two degrees can cut your cooling costs by at least 4%%, and in some cases by as much as 8%. Should I leave ceiling fans running all the time? No, because fans cool people, not rooms. Ceiling fans are less costly than air conditioning, but they still use electricity. Operating several fans 24 hours a day can add up quickly, especially if no one is home to benet from them. Operate the fan only when someone is in the room.

PAGE 2

2 Energy Ecient Homes: Ceiling Fans What features should I consider? Correct Sizing For maximum eciency, choose a ceiling fan that is the right size for the room. See Table 1 for the guidelines suggested by the American Lighting Association: Motors To ensure long life and quiet operation, purchase fans with motor housings constructed with heavier materials, such as die-cast metal. ese models tend to produce less vibration and provide better stability for downrods. Also look for models with heavy-duty windings, precision-engineered ball bearings, and shock-absorbent internal components. Performance-grade fans are designed for continuous, quiet operation. ey use larger, more powerful motors, and are generally the most expensive models. Medium-grade mod els are designed to operate 12 hours or fewer per day, and economy models are designed to operate 8 hours or fewer per day. You will have to do some research to determine fan grades. Check manufacturers websites for information. Motors come either with sealed and lubricated ball bearings, which require little or no maintenance, or with bearings that operate in an oil bath, which will occasionally require you to add oil. ree-speed motors are recommended for maximum comfort. Most fans (and all ENERGY STARqualied models) can reverse direction via a switch on the housing, so that they can move warm air (which rises up to the ceiling) down into the room during the winter. Blades Blades should be sealed or nished to prevent moisturecaused damage such as warping, peeling, or tarnishing, especially if the fan will be used in a high-humidity situation. More blades do not necessarily move more air. e pitch (angle of the fans blades), balance of the blades, length of the blades, motor design, motor speed, number of blades, etc., are all important in determining how much air a fan can move. Sound Try the fan out in the store using all settings to determine how loud it is. If it is too noisy, try a dierent brand, or a model with blades made of a dierent material. Can I install a ceiling fan in any room? e Energy Eciency and Renewable Energy (EERE) program at the U.S. Department of Energy indicates that for best performance, ceiling fans should only be installed in rooms where ceilings are 8 feet or higher. ey also recom mend installing ceiling fans so that the blades are no less than 8 inches from the ceiling and at least 18 inches from any given wall (Figure 1). Do fan/light combination units save energy? Fan/light units labeled with the ENERGY STAR logo (Figure 2) are about 60% more ecient than standard fan/ light units. is can save you $17 per year on utility bills (in addition to the heating and cooling savings gained by operating the fan properly, as described previously). Lights can also be purchased separately as an add-on to a ceiling fan. Most fans accept add-on light kits, though a number of them are only compatible within brands. Check the package for compatibility information. Separately sold ceiling fan light kits should be labeled ENERGY STAR when consider ing energy eciency. Table 1. Fan sizes suggested by the American Lighting Association Room Size (in ft 2 ) Suggested Fan Size (diameter) Small (up to 75 ft 2 ) 29 Medium (up to 144 ft 2 ) 36 Large (around 225 ft 2 ) 50 Figure 1. Minimum space requirements for a ceiling fan installation recommended by the U.S. Department of Energy Credits: Image created by Hyun-Jeong Lee in Microsoft Oce Visio; converted to .GIF by IFAS Communication Services.

PAGE 3

3 Energy Ecient Homes: Ceiling Fans Note that the Environmental Protection Agency (EPA) has a designation ENERGY STAR Most Ecient 2015 (Figure 3). is label recognizes products that deliver cutting-edge energy eciency along with the latest in technological in novation. e year included on the label designates that the device or appliance meets the criteria for the year indicated. Ceiling fans are one of several appliances or devices that have units meeting these criteria. If interested, begin your search at http://www.energystar.gov/mostecient Can I use a fan in damp areas? If youre installing a fan in a bathroom or other humid location, make sure it is UL-listed with a damp rating. If you are mounting a fan where it may come into direct contact with water (e.g., a porch or patio), be sure it has a UL wet rating. ese fans have features such as sealed or moisture-resistant motors, rust-resistant housings, stainless steel hardware, and all-weather blades (ENERGY STAR, n.d.-a). What are the current ENERGY STAR ceiling fan specications? e following ENERGY STAR ceiling fan specications became eective April 1, 2012 ( http://www.energystar.gov/ index.cfm?c=ceiling_fans.pr_crit_ceiling_fans ): Table 2. Equipment Specication Ceiling Fans Specication denes residential ceiling-fan airow eciency on a performance basis: cubic feet per minute (CFM) of airow per watt of power consumed by the motor and controls. Eciency is measured on each of 3 speeds. At low speed, fans must have a minimum airow of 1,250 CFM and an eciency of 155 CFM/watt. At medium speed, fans must have a minimum airow of 3,000 CFM and an eciency of 100 CFM/ watt. At high speed, fans must have a minimum airow of 5,000 CFM and an eciency of 75 CFM/watt. Qualifying ceiling fan models must come with a minimum 30-year motor warranty; one-year component(s) warranty; and a 2-year light kits warranty. Integral or attachable lighting, including separately sold ceiling fan light kits, must meet certain requirements of the Residential Light Fixtures (RLF) specication. See the Qualied Product Information (QPI) form for specic requirements. To help you evaluate dierent ceiling fans with lighting for purchase, click on the savings calculator link at http://www. energystar.gov/index.cfm?fuseaction=nd_a_product. showProductGroup&pgw_code=CF Note that, as of this writing, the U.S. Department of Energy (DOE) has federal design and test procedures for resi dential ceiling fans but no federal eciency performance standards. is may be changing in the future as the DOE published a notice in September 2014 announcing that they have conducted a preliminary analysis for the purposes of establishing energy conservation standards for ceiling fans. References and Resources American Lighting Association. (n.d.). Selecting a ceiling fan. Retrieved May 6, 2015, from http://www.american lightingassoc.com/Lighting-Your-Home/Ceiling-Fans.aspx ENERGY STAR. (n.d.-a). Ceiling fan basics. Retrieved May 6, 2015, from http://energystar.gov/index.cfm?c=ceiling_ fans.pr_ceiling_fans_basics Figure 2. Sample ENERGY STAR logo for use on qualied products only Credits: Courtesy of http://www.energystar.gov Figure 3. Sample ENERGY STAR Most Ecient logo for use on qualied products only Credits: Courtesy of http://www.energystar.gov

PAGE 4

4 Energy Ecient Homes: Ceiling Fans ENERGY STAR. (n.d.-b). Fans, Ceiling (for Con sumers). Retrieved May 6, 2015, from http://www. energystar.gov/index.cfm?fuseaction=nd_a_product. showProductGroup&pgw_code=CF U.S. Department of Energy. (n.d.-a). Fans for cooling. Retrieved May 6, 2015, from http://energy.gov/energysaver/ articles/fans-cooling U.S. Department of Energy. (n.d.-b). Residential: Ceiling Fans. Retrieved May 6, 2015, from http://eciency.lbl.gov/ product/ceiling-fans