Monthly performance report

MISSING IMAGE

Material Information

Title:
Monthly performance report Saddle Hill trust lot 73
Added title page title:
Saddle Hill trust lot 73
Physical Description:
v. : ill. ; 28 cm.
Language:
English
Creator:
United States -- Dept. of Energy
Publisher:
Dept. of Energy
Place of Publication:
Washington
Publication Date:

Subjects

Subjects / Keywords:
Solar energy -- Massachusetts -- Medway   ( lcsh )
Solar houses -- Massachusetts -- Medway   ( lcsh )
Genre:
federal government publication   ( marcgt )
non-fiction   ( marcgt )

Notes

General Note:
National solar data program.
General Note:
"SOLAR/1039-79/03" ; "SOLAR/1039-79/04" ; "SOLAR/1039-79/05."
General Note:
Monthly Catalog Number: gp 80010077
General Note:
National solar heating and cooling demonstration program.
General Note:
"SOLAR/1039-79/03" ; "SOLAR/1039-79/04" ; "SOLAR/1039-79/05 ; "SOLAR/1039-79/06."

Record Information

Source Institution:
University of Florida
Rights Management:
All applicable rights reserved by the source institution and holding location.
Resource Identifier:
aleph - 027069488
oclc - 05877423
System ID:
AA00013796:00004


This item is only available as the following downloads:


Full Text
I.' -
9 o L


SOLAR/1039-79/05

Monthly

Performance

Report




SADDLE HILL TRUST
LOT 73
MAY 1979


S. Department of Energy

National Solar Heating and
Cooling Demonstration Program


National Solar Data Program


I _


'7":









































NOTICE
This report was prepared as an account of work sponsored by the United States
Government. Neither the United States nor the United States Department of Energy, nor
any of their employees, nor any of their contractors, subcontractors, or their employees,
make any warranty, express or implied, or assume any legal liability or responsibility for
the accuracy, completeness or usefulness of any information, apparatus, product or
process disclosed, or represents that its use would not infringe privately owned rights.







MONTHLY PERFORMANCE REPORT


SADDLE HILL TRUST
LOT 73

MAY 1979


I. SYSTEM DESCRIPTION


Saddle Hill Trust Lot 73 is a single-family residence in Medway, Massachusetts.
Solar energy is used for preheating incoming city water. The system has an
array of flat-plate collectors with a gross area of 45 square feet. The array
faces south at an angle of 45 degrees to the horizontal. A 60 percent glycerol
solution is used as the medium for delivering solar energy from the collector
array to storage. Water is the transport medium that delivers solar energy to
storage and to the domestic-hot-water (DHW) heater. Solar energy is stored in
the basement in an 80-gallon preheat tank. This preheated city water is
supplied, on demand, to a conventional 40-gallon DHW tank. When solar energy
is insufficient to satisfy the hot water requirements, the gas-driven DHW
heater provides auxiliary energy for water heating. The system, shown sche-
matically in Figure 1, has two modes of solar operation.


Mode 1 Collector-to-Storage: This mode activates when a 40OF temperature
difference exists between the collector and the preheat tank. Pump P1 is on.
This mode continues operating until the temperature difference drops to 20F.


Mode 2 Storage-to-DHW Tank: This mode activates when there is a demand for
hot water. Hot water from the top of the preheat tank is transferred to the
DHW tank to replace the amount removed. Simultaneously, city water is auto-
matically supplied to the preheat tank.













V TO01
0 1001


T150


T100


IW100


T202


,a


COLD
WATER
SUPPLY










HOT
*WATER
SERVICE


IT302


F300


Figure 1. SADDLE HILL TRUST, LOT NO. 73 SOLAR ENERGY SYSTEM SCHEMATIC







II. PERFORMANCE EVALUATION


INTRODUCTION


The site was occupied in May and the solar energy system operated contin-
uously during the month. Total solar energy collected was 1.1 million Btu
and the total solar energy used was 0.68 million Btu or 62 percent of the
collected energy. The change in stored energy was 0.01 million Btu, while
the loss from storage amounted to 0.29 million Btu. Solar energy satisfied
57 percent of the DHW requirements. The solar energy system provided fossil
fuel savings of 1.1 million Btu and incurred an electrical expense of 0.17
million Btu.



WEATHER CONDITIONS


During the month, total incident solar energy on the collector array was
1.8 million Btu for a daily average of 1292 Btu per square foot. This was
below the estimated average daily solar radiation for this geographical
area during May of 1433 Btu per square foot for a south-facing plane with a
tilt of 45 degrees to the horizontal. The average ambient temperature
during May was 610F as compared with the long-term average for May of 590F.



THERMAL PERFORMANCE


System During May the solar energy system performed approximately the same
as expected. The expected performance was determined from a modified f-chart
analysis using measured weather and subsystem loads as input. Solar energy
used by the system was estimated by assuming that all energy collected would
be applied to the load. Actual solar energy used was 0.68 million Btu versus
an estimated 0.76 million Btu. System total solar fraction was 57 percent
versus an estimated 64 percent.








Collector The total incident solar radiation on the collector array for
the month of May was 1.8 million Btu. During the period the collector loop
was operating, the total insolation amounted to 1.6 million Btu. The total
collected solar energy for the month of May was 1.1 million Btu, resulting
in a collector array efficiency of 59 percent, based on total incident
insolation. Solar energy delivered from the collector array to storage was
0.98 million Btu. Energy loss during transfer from the collector array to
storage was 0.12 million Btu. This loss represented 11 percent of the
energy collected. Operating energy required by the collector loop was 0.17
million Btu.


Storage Solar energy delivered to storage was 0.98 million Btu. There were
0.68 million Btu delivered from storage to the DHW subsystem. Energy loss
from storage was 0.29 million Btu. This loss represented 29 percent of the
energy delivered to storage. The storage efficiency was 71 percent: This
is calculated as the ratio of the sum of the energy removed from storage and
the change in stored energy, to the energy delivered to storage. The average
storage temperature for the month was 910F.


DHW Load The DHW subsystem consumed 0.68 million Btu of solar energy and
0.86 million Btu of auxiliary fossil fuel energy to satisfy a hot water load
of 1.1 million Btu. The solar fraction of this load was 57 percent.
Losses from the DHW subsystem were 0.098 million Btu. A daily average of 59
gallons of DHW was consumed at an average temperature of 1280F delivered from
the tank.



OBSERVATIONS


There are no significant observations to report.








ENERGY SAVINGS


The solar energy system provided a fossil fuel energy savings of 1.1 million
Btu, while incurring an electrical energy expense of 0.17 million Btu.



III. ACTION STATUS


There are no significant items to report.









SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM


MONTHLY REPORT
SITE SUMMARY


SITE: SADDLE HILLS TRUST LOT #73 MEDkAY, MA 02053 SOLAR/1039-79/05
REPORT PERIOD: MAY,179

SITE/SYSTEM DESCRIPTION:
THE SADDLE HILL TRUST LOT #73 SOLAR ENERGY SYSTEM FURNISHES HOT WATER
YEAR-ROUND TO A SINGLE FAMILY DWELLING. THE COLLECTOR IS A TWO-PANEL
LIQUID COLLECTOR. STORAGE SPACE IS AN 80 GALLCN WATER TANK.
AUXILIARY HOT WATER IS PROVIDED BY A GAS HOT WATER HEATER.


GENERAL SITE DATA:
INCIDENT SOLAR ENERGY


COLLECTED SOLAR EhERGY
AVERAGE AMBIENT TEMPERATURE
AVERAGE BUILDING TEMPERATURE
ECSS SOLAR CONVERSION EFFICIENCY
ECSS OPERATING ENERGY
TOTAL SYSTEM OPERATING ENERGY
TOTAL ENERGY CONSUMED


1.802
40038
1.065
23661
61
N .A.
0.38
0.170
0.170
2. 092


MILLION BTU
BTU/SQ.FT.
MILLION BTU
BTU/SQ.FT.
DEGREES F
DEGREES F
MILLION BTU
MILLION BTU
MILLION BTU


SUBSYSTEM SUMMARY:
LOAD
SOLAR FRACTION
SOLAR ENERGY USED
OPERATING ENERGY
AUX. THERMAL ENERGY
AUX. ELECTRIC FUEL
AUX. FOSSIL FUEL
ELECTRICAL SAVINGS
FOSSIL SAVINGS


HOT WATER
1.097
57
0.681
N.A.
0.514
N.A.
0.857
N.A.
1 .136


HEATING
N.A.
N.A.
N.A.
N. A
N.A.
N.A.
N.A.
N.A.
N.A.


COOLING
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N. A.
N.A.


SYSTEM TOTAL
1.097 MILLION BTU
57 PERCENT
0.681 MILLION BTU
0.170 MILLION BTU
0.514 MILLION BTU
N.A. MILLION BTU
0.857 MILLION BTU
-0.170 MILLION BTU
1.136 MILLION BTU


SYSTEM PERFORMANCE FACTOR:


0.771


* DENOTES UNAVAILABLE DATA
@ DENOTES NULL DATA
N.A. DENOTES NOT APPLICABLE DATA
REFERENCE: USER'S GUIDE TO THE MONTHLY PERFORMANCE REPORT
OF THE NATIONAL SOLAR DATA PRCGRAM,FEBRUARY 28,1978,
SOLAR/0004-78/18








SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM


MONTHLY REPORT
SITE SUMMARY
SITE: SADDLE HILLS TRUST LOT #73 MEDWAY, MA 02053
REPORT PERIOD: MAY,179


SITE/SYSTEM DESCRIPTION:
THE SADDLE HILL TRUST LOT #73 SOLAR ENERGY SYSTEM FURNISHES HOT WATER
YEAR-ROUND TO A SINGLE FAMILY DWELLING. THE COLLECTOR IS A TWO-PANEL
LIQUID COLLECTOR. STORAGE SPACE IS AN 80 GALLON WATER TANK.
AUXILIARY HOT WATER IS PROVIDED BY A GAS HCT WATER HEATER.


GENERAL SITE DATA:
INCIDENT SOLAR ENERGY


COLLECTED SOLAR ENERGY
AVERAGE AMBIENT TEMPERATURE
AVERAGE BUILDING TEMPERATURE
ECSS SOLAR CONVERSION EFFICIENCY
ECSS OPERATING ENERGY
TOTAL SYSTEM OPERATING ENERGY
TOTAL ENERGY CONSUMED


SUBSYSTEM SUMMARY:
LOAD
SOLAR FRACTION
SOLAR ENERGY USED
OPERATING ENERGY
AUX. THERMAL ENG
AUX. ELECTRIC FUEL
AUX. FOSSIL FUEL
ELECTRICAL SAVINGS
FOSSIL SAVINGS


HCT WATER
1.157
57
0.719
N.A.
0.543
N.A.
0.904
N.A.
1.198


HEATING
N.A.
N.A.
N. A.
N.A.
N. A.
N. A.
N.A.
N. A.
N. A.


COOLING
N. A.
NA.
N. A.
N.A.
N.A.
N,A.
NA.
N.A.
N. A.


1.901 GIGA JOULES
454669 KJ/SQ.M.
1.123 GIGA JOULES
268694 KJ/SQ.M.
16 DEGREES C
N.A. DEGREES C
0.38
0.179 GIGA JOULES
0.179 GIGA JOULES
2.207 GIGA JOULES

SYSTEM TOTAL
1.157 GIGA JOULES
57 PERCENT
0.719 GIGA JOULES
0.179 GIGA JOULES
0.543 GIGA JOULES
N.A. GIGA JOULES
0.904 GIGA JOULFS
-0.179 GIGA JOULES
1.198 GIGA JOULES


SYSTEM PERFORMANCE FACTOR:


0.771


* DENOTES UNAVAILABLE DATA
a DENOTES NULL DATA
N.A. DENOTES NOT APPLICABLE DATA
REFERENCE: USER'S GUIDE TO THE MONTHLY PERFORMANCE REPORT
OF THE NATIONAL SOLAR DATA PROGRAM,FEBRUARY 28,1978,
SOLAR/0004-78/18


SOLAR/1039-79/05






SCLAR HEATING AND COOLING CEMCNSTRATION PROGRAM
MONTHLY REPORT
ENERGY COLLECTION AND STORAGE SUBSYSTEM (ECSS)


SITE: SADDLE HILLS TRUST LOT #73 MEDWAY, MA 02053
REPORT PERIOD: MAY,1979


DAY
OF
MONTH


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
SUM
AVG
NBS ID


INCIDENT
SOLAR
ENERGY
MILLION
BTU
0.086
0.105
0.074
0.074
0. 106
0.083
0.099
0.095
0.089
0.086
0.093
0.034
0.020
0.014
0.014
0.066
0.073
0.034
0.019
0.019
0.043
0.097
0.021
0.008
0.017
0.037
0.082
0.016
0.081
0.016
0.099
1.802
0.058
Q001


I-----------
AMBIENT
TEMP

I EG-F
58
54
56
65
57
56
62
65
81
85
64
60
63
62
61
66
57
55
52
54
61
68
55
52
56
55
63
59
67
57
68


61
N113


I----------I
ENERGY
TO
LOADS
MILLION
BTU
0.021
0.030
0.035
0.031
S 0.037
0.026
0.023
0.047
0.031
0.045
0.037
0.019
0.006
0.015
.0.008
0.021
0.018
0.024
0.011
0.008
0.007
0.029
0.018
0.014
0.003
0.012
0.025
0.013
0.011
0.024
0.033
0.681
0.022

--------- I


AUX
THERMAL
TO ECSS
MILLION
BTU
N
C
T
A
P
P
L
I
C
A
B
L
E














N.A.
N.A.


ECSS
ENERGY
REJECTED
MILLION
BTU
N
T

A
P
P
L
I
C
A
B
L
E


ECSS
OPERATING
ENERGY
MILLION
BTU
0.007
0.006
0.005
0.007
0.007
0. 005
0.006
0.007
0.007
0.007
0.007
0.007
0.004
0.005
0.005
0.007
0.007
0.005
0.005
0.005
0.006
0.0007
0.004
0.000
0.005
0.005
0.007
0.003
0.006
0.003
0.007
0.170
0.005
Q102


ECSS SOLAR
CONVERSION
EFFICIENCY


0.249
0.286
0.470
0.414
0.352
0.319
0.236
0.495
0.349
0.525
0. 397
0.544
0.292
1.076
0.556
0.315
0.241
0.716
0.580
0.392
0.160
0.300
0.856
1.731
0. 177
0.321
0.303
0.830
0.133
1 .466
0.338


0.378
N111


* DENOTES UNAVAILABLE DATA.
@ DENOTES NULL DATA.
N.A. DENOTES NOT APPLICABLE CATA.


SOLAR/1039-79/05


N. A.
N.A.





SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM


MONTHLY REPORT
COLLECTOR ARRAY PERFORMANCE
SITE: SADDLE HILLS TRUST LOT #73 MEDWAY, MA 0205SOLAR/1039-79/05
REPORT PERIOD: MAY,1979


DAY
OF
MONTH



2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
SUM
AVG
NBS ID
I ---- ---


INCIDENT
SOLAR
ENERGY
MILLION
BTU
0. C86
0.105
0.074
0.074
0.106
0.083
0 099
0.095
0.089
0.086
0.093
0.034
0.020
0.014
0.014
0.066
0.073
0.034
0.019
0,019
0.043
0.097
0.021
0.008
0.017
0.037
0.082
0.016
0.081
0.016
0.099
1.8C2
0.058
Q001


OPERATIONAL
INCIDENT
ENERGY
MILLION
BTU
0.082
C.099
0.066
0.071
0.103
0.076
0.092
0.090
0.085
0.082
0.089
0.031
0.014
0.010
0.011
0.062
0.068
0.030
0.015
0.014
0.039
0.092
0.015
0.000
0.014
0.032
0.077
0.009
0.074
0.011
0.095
1.648
0.053


COLLECTED
SCLAR
ENERGY
MILLION
BTL
0.057
C. C62
0.045
0.048
0. 65
0.051
C.C57
0.059
0.057
C. C55
0.057
0.018
0.C07
0.005
C CC6
0.0C43
0 042
C. C19
0.008
0.008
C. C26
0.059
O.CC8
0.000
0 009
C.C20
0.047
0.005
0.051
0.006
I 0. 64
1.065
0.034
QlO


---------
DAYTIME
AMBIENT
TEMP
DEG F


72
69
70
80
66
70
75
79
96
99
70
67
67
65
63
79
66
57
54
56
65
81
63
52
59
57
74
60
80
60
84


70
70


COLLECTOR
ARRAY
EFFICIENCY


0.661
0.591
0.609
0.656
0.614
0.619
0.568
0.622
0.642
0.637
0.616
0.531
0.324
0.379
0.425
0.654
0.567
0.552
0.402
0.410
0.602
0.609
0.401
0. 000
0.513
0. 546
0.572
0.347
0.630
0.387
0.642


0.591
SN100


DENOTES UNAVAILABLE DATA.
S DENOTES NULL DATA.
N.A. DENOTES NOT APPLICABLE DATA.





SOLAR HEATING AND COOLING CEMCNSTRATION PROGRAM
MONTHLY REPORT
STORAGE PERFORMANCE
SITE: SADDLE HILLS TRUST LOT #73 MECWAY, MA 0205SOLAR/1039-79/05
REPORT PERIOD: MAY,1979


DAY
OF
MONTH


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
SUM
AVG
NBS ID


ENERGY
TO
STORAGE
MILLION
BTU
0.052
0.055
0.041
0.046
0.061
0.046
0.050
0.054
0.052
0.051
0.053
0.017
0.007
0.005
0.007
0.042
0.039
0.018
0.006
0.006
0.025
0.055
0.007
0.000
0.007
0.019
0.043
0.005
0.047
0.005
0.060
0.981
0.032
Q200
Q200-


ENERGY
FROM
STORAGE
MILLION
BTU
C.021
0.030
0. 035
0.031
0.037
C. 026
0.023
0.047
C.031
0.045
C. 037
0.019
0.006
C. 015
0.008
0.021
C.C18
0.024
C. 011
0.008
0.007
C. 29
0.018
C0.014
C C03
0.012
0. 025
0.013
0.011
C. 024
0.033
C.681
0.022
C201


---------- I
CHANGE
IN STORED
ENERGY
MILLION
BTU
0. C19
0.006
-0.010
0. CC4
0.008
C.CC2
0 009
-0.016
C.CC6
-0.011
-0.001
-0. C06
-0.002
-C. C09
0.012
C. C11
-0.014
-0.005
-C. CC
0.014
C.C07
-0.014
-0.014
C. C06
0.003
0.CC4
-0. 007
0.023
-C.C22
C.C11
C. 12
C.CCO
Q202


STORAGE
EFFICIENCY


STORAGE
AVERAGE
TEMP
DEG F

87
111
102
93
105
105
123
117
113
112
104
89
86
73
68
81
96
85
75
73
79
105
89
69
66
74
94
74
94
87
90


91


0.707
N108


* DENOTES UNAVAILABLE DATA.
@ DENOTES NLLL DATA.
N.A. DENOTES NOT APPLICABLE DATA.


0.782
0.663
0.614
0. 746
0.745
0.607
0. 660
0.582
0.705
0.667
0.682
0.742
0.506
1.204
1. 210
0.771
0.724
0.600
0.952
0.965
0.830
0.667
0. 553
1.000
1.213
0.788
0.672
1.219
0.716
0.310
0.735





SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM
MONTHLY REPORT
HOT WATER SUBSYSTEM


SITE: SADDLE HILLS TRUST LOT
REPORT PERIOD: MAY,1979


#73 MEDWAY, MA 02053


SOLAR/1039-79/05


DAY
OF
MON.


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
SUM
AVG
NBS


HOT
WATER
LOAD
MI LI ON
BTU
0.041
0.034
0.035
0.047
0.052
0.027
0.023
0.044
0.030
0.044
0.042
0.025
0.012
0.047
0.040
0.050
0.028
0.043
0.033
0.031
0.028
0. 040
0.019
0.050
0.027
0.039
0.026
0.028
0.025
0.037
0.048
1.097
0.035
Q302


SOLAR
FR.OF
LOAD
PER
CENT
45
57
85
70
65
85
77
93
98
99
92
85
641
44
27
28
49
55'
36
26
23
42
74
42
18
21
55
56
38
58
58


57
N300
I-~---


SOLAR
ENERGY
USED
MI LLI GN
BTU
0.021
0.030
0.035
0.031
0.0371
0.026
0.023
0.047
0.031
0.0451
0.0371
0. 019
0.0061
0.015
0.008
0.021
0.018
0.024
0.011
0. 008
0.0071
0.029
0 018
0.0141
0.003
0.01.2
0.025
0.013
0.011!
0.024
0.033
0.681
-,RI
0.022
Q300


OPER
ENERGY
MILLION
BTU
N
0
T
A
P
P
L
I
C
Al
B
L
E














N.A.
N.A.i
Q303


AUX
THERMAL
USED
MILLION
BTU
0.020
0.015
0.000
0.019
0.018
0.007
0.000
0.000
0.000
C.000
0.005
0.010
0.008
0.034
0.037
0.032
0.008
0.027
0.029
0.029
0.021
0.016
C.000
0.045
0.030
0.033
0.000
0.022
0.016
0.016
0.017
0.514
0.017
Q301


AUX
ELECT
FUEL
MILLION
BTU
N!
C
T
A
P1
L
I
C
Al
B
L
El














N.A.
N.A.1
Q305


I--------
AUX
FOSSIL
FUEL
MILLION
SBTU
0 .033
0.024
0.000|
0.032
0.031
0.0111
0.000
0.000
0.0001
0.000
0.009|
0.017,
0.014
0.057
0.061
0.053
0.0141
0.045
0.048
0.049
0.036
0.0261
0.000
0.076
0.0501
0.055
0.0001
0,037
0.026
0.0271
0.028
0.857!
0.028
Q306 .


ELECT
ENERGY
SAVINGS
MILLION
BTU
N
0
T
A
P
P
L
I
C
A
B
L
E














N.A.
N.A.
Q311


FOSSIL
ENERGY
SA VI NG S
MILLION
BTU
0.036
0.050
0.058
0.0511
0.062
0.044
0 .039
0.079
0.0521
0.075
0.061
0 .0311
0.010
0.025
0.0131
0.034
0.029
0.040
0.018
0.0131
0.011
0.049
0 .030
0.023
0.005
0.020
0.042
0.022
0.018
0.040
0.056
1.136
0.037
0313


SUP.
WAT.
TEMP
DEG
F
531
54
57
561
57
59
591
59
63'
621
58
61
59
60
611
60
58
601
65
641
61
62
601
59
61
59,
61
62
62
60
601


60
N305


S---I
HOT
WAT.
TEMP
DEG
F
129
12r,
120
1241
126
118
1201
125
124'
1251
128
125
125
135
1411
137
127
127
131
132
132
128
1241
131
132
1301
127
120
133
127
1301


128
N307
---- I


* DENOTES UNAVAILABLE DATA.
@ DENOTES NULL DATA.
N.A. DENOTES NOT APPLICABLE


HOT
WATER
USED
GAL
63
541
63
78
83
51
41
73
52
75
71
44
23
74
641
80
49
74
55
48!
45
67
341
79
44
65
49
48
42
66
831
-
1835
S----- 1
S59
N308 1


DATA.






SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM
MONTHLY REPORT
ENVIRONMENTAL SUMMARY
SITE: SADDLE HILLS TRUST LOT #73 MEDWAY, MA 02053
REPORT PERIOD: MAY,1979


SOLAR/1039-79/05


TOTAL
INSOLATION
BTU/SQ.FT
1917
2330
1642
1640
2366
1843
2210
2117
1975
1908
2066
763
449
310
313
1462
1627
752
422
427
956
2161
460
174
385
824
1828
352
1794
363
2202
40038
1292
Q001


DIFFUSE
INSOLATION
BTU/SQ.FT
N
0
T
A
P
P
L
I
C
A
B
L
E














N.A.
N.A.


AMBIENT
TEMPERATURE,
DEG F
58
54
56
65
57
56
62
65
81
64
60
63
62
61
66
57
55
52
54
61
68
55
52
56
55
63
59
67
57
68


61
N113


DAYTIME
AMBIENT
TEMP
CEG F
72
69
70
80
66
70
75
79
96
99
70
67
67
65
63
79
66
57
54
56
65
81
63
52
59
57
74
60
80
60
84

70---
70


RELATIVE E
HUMIDITY
PERCENT
N
0
T
A
P
P
L
I
C
A
B
L
E


N.A.


WIND
DIRECTION
DEGREES
N
0
T
A
P
P
L
I
C
A
B
L
E













-- ----
N.A.
N115


WIND
SPEED
M.P.H.
N
0
T
A
P
P
L
I
C
A
B
L
E














- --- -
N.A.
N114
I- --------


* DENOTES UNAVAILABLE DATA.
a DENOTES NULL DATA.
N.A. DENOTES NOT APPLICABLE DATA.







UNIVERSITY OF FLORIDA
III111111111111IIII IIIIIl 1111 I IIf II IIIIIHIHII
3 1262 09052 6095


I




Full Text
xml version 1.0 encoding UTF-8
REPORT xmlns http:www.fcla.edudlsmddaitss xmlns:xsi http:www.w3.org2001XMLSchema-instance xsi:schemaLocation http:www.fcla.edudlsmddaitssdaitssReport.xsd
INGEST IEID EI15BG8EG_83K4EY INGEST_TIME 2014-04-10T01:03:06Z PACKAGE AA00013796_00004
AGREEMENT_INFO ACCOUNT UF PROJECT UFDC
FILES