Monthly performance report

MISSING IMAGE

Material Information

Title:
Monthly performance report Saddle Hill trust lot 77
Added title page title:
Saddle Hill trust lot 77
Physical Description:
v. : ill. ; 28 cm.
Language:
English
Creator:
United States -- Dept. of Energy
Publisher:
Dept. of Energy
Place of Publication:
Washington
Publication Date:

Subjects

Subjects / Keywords:
Solar energy -- Massachusetts -- Medway   ( lcsh )
Solar houses -- Massachusetts -- Medway   ( lcsh )
Genre:
federal government publication   ( marcgt )
non-fiction   ( marcgt )

Notes

General Note:
"SOLAR/1040-79/01" ; "SOLAR/1040-79-02" ; "SOLAR/1040-79/03" ; "SOLAR/1040-79/04" ; "SOLAR/1040-79/05."
General Note:
National solar heating and cooling demonstration program, National solar data program.
General Note:
Monthly Catalog Number: gp 80007760
General Note:
"SOLAR/1040-79/01" ; "SOLAR/1040-79/03" ; "SOLAR/1040-79/04" ; "SOLAR/1040-79/05."

Record Information

Source Institution:
University of Florida
Rights Management:
All applicable rights reserved by the source institution and holding location.
Resource Identifier:
aleph - 027035022
oclc - 05855572
System ID:
AA00013795:00002


This item is only available as the following downloads:


Full Text
I L


SOLAR/1040-79/01

Monthly

Performance

Report


SADDLE HILL TRUST
LOT 77
JANUARY 1979


U.S. Department of Energy

National Solar Heating and
Cooling Demonstration Program


National Solar Data Program


I


I







































NOTICE
This report was prepared as an account of work sponsored by the United States
Government. Neither the United States nor the United States Department of Energy, nor
any of their employees, nor any of their contractors, subcontractors, or their employees.
make any warranty, express or implied, or assume any legal liability or responsibility for
the accuracy, completeness or usefulness of any information, apparatus, product or
process disclosed, or represents that its use would not infringe privately owned rights.








MONTHLY PERFORMANCE REPORT


SADDLE HILL TRUST
LOT 77

JANUARY 1979


I. SYSTEM DESCRIPTION

Saddle Hill Trust Lot 77 is a single-family residence in Medway, Massachusetts.
Solar energy is used for preheating incoming city water. The system has an
array of flat-plate collectors with a gross area of 78 square feet. The array
faces south at an angle of 38 degrees to the horizontal. Air is used as the
medium for delivering solar energy from the collector array to an air-to-
liquid heat exchanger located in the collector air duct. Water is the medium
used to transport solar energy from the heat exchanger to storage. Solar
energy is stored in the basement in a 120-gallon preheat storage tank. This
preheated city water is supplied, on demand, to a conventional 40-gallon
domestic-hot-water (DHW) tank. When solar energy is insufficient to satisfy
the hot water requirements, the gas-driven DHW heater provides auxiliary
energy for water heating. The system, shown schematically in Figure i, has
two modes of solar operation.

Mode 1 Collector-to-Storage: This mode activates when the difference be-
tween the temperature of the collector air and the temperature of the water in
the preheat tank exceeds 400F and the temperature of the water in the tank is
below 1400F. Both the fan and pump go on. This mode continues until the
temperature difference drops to 200F.

Mode 2 Storage-to-Space Heating: This mode activates when there is a demand
for hot water. Hot water from the top of the preheat tank is transferred to
the DHW tank to replace water removed. Simultaneously, city water is automatically
supplied to the preheat tank.

II. PERFORMANCE EVALUATION

INTRODUCTION

The site was occupied in January and the solar energy system operated contin-
uously during the month. Solar energy satisfied 17 percent of the DHW require-
ments. The solar energy system provided a fossil fuel energy savings of 0.46
million Btu and incurred an electrical energy expense of 0.050 million Btu.


WEATHER CONDITIONS

During the month, total incident solar energy on the collector array was
1.6 million Btu for a daily average of 671 Btu per square foot. This was
below the estimated average daily solar radiation for this geographical area
during January of 796 Btu per square foot for a south-facing plane with a













1001 COLLECTOR PLANE TOTAL INSOLATION
A T001 OUTDOOR TEMPERATURE

T150













TI T2 W201
W100 W20
IQAL


Figure 1. SADDLE HILL TRUST, LOT NO. 77, SOLAR ENERGY SYSTEM SCHEMA TIC








tilt of 38 degrees to the horizontal. The average ambient temperature during
January was 290F and was equal to the long-term average for January.


THERMAL PERFORMANCE

System During January the solar energy system performed somewhat better than
expected. The expected performance was determined from a modified f-chart
analysis using measured weather and the DHW subsystem load as inputs. Solar
energy collected was 0.36 million Btu versus an estimated 0.21 million Btu.
Solar energy used by the system was estimated by assuming that all energy
collected would be applied to the load. Actual solar energy used was 0.32
million Btu. System total solar fraction was 17 percent versus an estimated
9 percent.

Collector The total incident solar radiation on the collector array for the
month of January was 1.6 million Btu. During the period the collector loop
was operating, the total insolation amounted to 1.2 million Btu. The total
collected solar energy for the month of January was 0.36 million Btu, result-
ing in a collector array efficiency of 22 percent, based on total incident
insolation. Operating energy required by the collector loop was 0.050 million
Btu.

DHW Load The DHW subsystem consumed 0.32 million Btu of solar energy and
3.3 million Btu of auxiliary fossil fuel energy to satisfy a hot water load
of 1.8 million Btu. The solar fraction of this load was 17 percent. Losses
from the DHW subsystem were 0.49 million Btu. A daily average of 72 gallons
of DHW was consumed at an average temperature of 1460F delivered from the
tank.


OBSERVATIONS

A portion of the 0.49 million Btu loss in the DHW subsystem was probably used
to maintain a relatively high temperature in the DHW tank.


ENERGY SAVINGS

The solar energy system incurred an electrical energy expense of 0.05 million
Btu and provided a fossil fuel energy savings of 0.46 million Btu.


III. ACTION STATUS

No action is required at this time.











SOLAR HEATING AND CCCLING DEMONSTRATION PROGRAM


MONTHLY REPORT
SITE SUMMARY


SITE: SADDLE HILLS TRUST LOT 577, MEDWAYMA 02053 SOLAR/1039-79/01
REPORT PERIOD: JANUARY.1979


SITE/SYSTEM DESCRIPTION:
THE SADDLE HILL TRUST. LOT 77. SOLAR SYSTEM PROVIDES YEAR ROUND HOT
WATER TO A SINGLE FAMILY DETACHED HOUSE. THE COLLECTOR IS A SCLAFON
2000 FOUR PANEL AIR COLLECTOR. STORAGE IS A 120 GALLON WATER TANK.
AUXILIARY HOT WATER IS PROVIDED BY A GAS DOMESTIC HOT WATER HEATER.


GENERAL SITE DATA:
INCIDENT SOLAR ENERGY


COLLECTED SOLAR ENERGY

AVERAGE AMBIENT TEMPERATURE
AVERAGE BUILDING TEMPERATURE
ECSS SOLAR CONVERSION EFFICIENCY
ECSS OPERATING ENERGY
TOTAL SYSTEM OPERATING ENERGY
TOTAL ENERGY CONSUMED


1.623
20809
0.355
4555
29
N.A.
0.20
0.050
0.050
3.6;90


MILLION BTU
BTU/SC.FT.
MILLION BTU
BTU/SQ.FT.
DEGREES F
DEGREES F

MILLION BTU
MILLION BTU
MILLION BTU


SUBSYSTEM SUMMARY:

LOAD
SOLAR FRACTION
SOLAR ENERGY USED
OPERATING ENERGY
AUX. THERMAL ENERGY
AUX. ELECTRIC FUEL
AUX. FOSSIL FUEL
ELECTRICAL SAVINGS
FOSSIL SAVINGS


HOT WATER
1.806
17
0.321
N.A.
1.971
N.A.
3.285
-0.050
0 .461


HEATING
N.A.
N.A.
N.A.
N.A.
N.A.
N. A.
N.A.
N. A
N.A.


COOLING
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.


SYSTEM TOTAL
1.800 MILLION BTU
17 PERCENT
0.321 MILLION BTU
0.050 MILLION BTU
1.971 MILLION BTU
h.A. NILLICN BTU
3.2P5 MILLION BTU
-0.050 MILLION BTU
0.461 MILLION BTU


SYSTEM PERFORMANCE FACTOR:


0.524


* DENOTES UNAVAILABLE DATA
M DENOTES NULL DATA
N.A. DENOTES NOT APPLICABLE DATA

REFERENCE: USER'S GUIDE TO THE MONTHLY PERFORMANCE REPORT
OF THE NATIONAL SOLAR DATA PROGRAMFEBRUARY 2891978.
SOLAR/0004-78/18










SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM


MONTHLY REPORT
SITE SUMMARY


SOLAR/1029-79/01


SITE: SADDLE HILLS TRUST LOT #77. MEDWAYMA 02053
REPORT PERIOD: JANUARY.1979


SITE/SYSTEM DESCRIPTION:
THE SADDLE HILL TRUST. LOT 77, SOLAR SYSTEM PROVIDES YEAR ROUND HOT
WATER TO A SINGLE FAMILY DETACHED HOUSE. THE COLLECTOR IS A SCLARON
2000 FOUR PANEL AIR COLLECTOR. STORAGE IS A 120 GALLON WATER TANK.
AUXILIARY HOT WATER IS PROVIDED BY A GAS DOMESTIC HOT WATER HEATER.


GENERAL SITE DATA:
INCIDENT SOLAR ENERGY


COLLECTED SOLAR ENERGY

AVERAGE AMBIENT TEMPERATURE
AVERAGE BUILDING TEMPERATURE
ECSS SOLAR CONVERSION EFFICIENCY
ECSS OPERATING ENERGY
TOTAL SYSTEM OPERATING ENERGY
TOTAL ENERGY CONSUMED


1.712
236308
0.375
51728
-2
N.A.
C.2C
0.052
0.052
3.892


GIGA JOULES
KJ/SQ.M.
GIGA JOULES
KJ/SQ.M.
DEGREES C
DEGREES C


GIGA
GIGA
GIGA


JOULES
JOULES
JOULES


SUBSYSTEM SUMMARY:

LOAD
SOLAR FRACTION
SOLAR ENERGY USED
OPERATING ENERGY
AUX. THERMAL ENG
AUX. ELECTRIC FUEL
AUX. FOSSIL FUEL
ELECTRICAL SAVINGS
FOSSIL SAVINGS


HOT WATER
1.905
17
0.339
N.A.
2.079
N.A.
3.465
-0.052
0.487


HEATING
N.A.
N. A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.


COOLING
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.


SYSTEM TOTAL
1.905 GIGA JOULES
17 PERCENT
0.339 GIGA JCULES
0.052 GIGA .IOULES
2.079 GIGA JOULES
N.A. GIGA JOULES
3.465 GIGA JOULES
-0.052 GIGA JOLLES
0.487 GIGA JOULES


SYSTEM PERFORMANCE FACTOR:


0.524


* DENOTES UNAVAILABLE DATA
a DENOTES NULL DATA
N.A. DENOTES NOT APPLICABLE DATA

REFERENCE: USER'S GUIDE TO THE MONTHLY PERFORMANCE REPORT
OF THE NATIONAL SOLAR DATA PROGRAMFEBRUARY 28,1978,
SOLAR/0004-78/18









SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM

MONTHLY REPORT
ENERGY COLLECTION AND STORAGE SUBSYSTEM (ECSS)


SOLAR/1029-79/01


SITE: SADDLE HILLS TRUST LOT #77. MEDWAYMA 02053
REPORT PERIOD: JANUARY.1979


DAY
OF
MONTH


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

SUM

AVG

NBS ID


INCIDENT
SOLAR
ENERGY
MI LL I ON
BT U

0. 001
0.003
0. 113
0. 118
0. 090
0. 029
0. 006
0. 002
0. 121
0.112
0.129
0. 064
0. 006
0. 004
0.110
0. 062
0.021
0. 055
0.131
0. 052
0.001
0.012
0. 133
0.023
0.001
0. 009
0. 018
0. 028
0. 057
0.048
0.063

1.623

0. 052

0001


AMBIENT
TEMP

DEG-F

53
57
25
15
16
24
30
42
25
20
14
14
28
36
22
24
16
15
11
19
40
35
32
32
40
36
39
37
40
37
31


29

N113


ENERGY
TO
LOADS
MILLION
BTU

0.000
0.000
0 030
0.028
0.023
0.000
0.000
0.000
0.032
0. 020
0.019
0. 006
0.000
0.000
0.027
0.013
0. 000
0.000
0.028
0.008
0.000
0.000
0.038
0.000
0.000
0.000
0.000
0.007
0.017
0.011
0.014

0.321

0.010
-~-~~~ I


AUX
THERMAL
TO ECSS
MILLION
BTU

N
O
T

A
P
P
L
I
C
A
B
L
E


N.A.

N.A.


ECSS
OPERATING
ENERGY
MILLION
BTU

0.000
0.000
0.004
0.004
0.003
0.000
0.000
0.000
0.004
0.004
0.004
0.002
0.000
0.000
0.004
0.002
0.000
0.001
0.004
0.002
0.000
0.000
0.005
0.000
0.000
0.000
0.000
0.001
0.002
0.001
0.002

0.050

0.002

0102


ECSS
ENERGY
REJECTED
MILLION
BTU

N
0
T

A
P
P
L
I
C
A
B
L
E


N.A.
N.A.
No A*


ECSS SOLAR
CONVERSION
EFFICIENCY


0.000
0.000
0.266
0.239
0.254
0.000
0. 00
0.000
0.26?
0.181
0.150
0.088
0.000
0.000
0.244
0.211
0.018
0.000
0.212
0. 150
0.000
0.000
0.286
0.000
0.000
0.000
0 000
0.261
0.300
0.221
0.223


0.198

N111
---------I~


* DENOTES UNAVAILABLE DATA.
a DENOTES NULL DATA.
N.A. DENOTES NOT APPLICABLE CATA.






I"'


MONTHLY REPORT
COLLECTOR ARRAY PERFORMANCE

SITE: SADDLE HILLS TRUST LOT #77, MEDWAYMA 02053SOLAR/1039-79/01
REPORT PERIOD: JANUARY,1979


i----------
DAY
OF
MONTH


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

SUM

AVG

NBSID


INCIDENT
SOLAR
ENERGY
MILLION
BTU

0.001
00003
0.113
0.118
0.090
0 029
0.006
00002
0.121
0.112
0.129
0.064
0.006
0.004
0.110
0.062
0.021
0.055
0.131
0.052
0.001
0.012
0 133
0.023
0.001
00009
0.018
0.028
0 057
0.048
0,063

1.623

0.052

QO01


-----------
OPERATIONAL
INCIDENT
ENERGY
MILLION
BTU

0.000
0.000
0.103
0.100
0.078
0.000
0.000
0.000
0.108
0.095
0.111
0.040
0.000
0.000
0.094
0.043
0.001
0.003
0.099
0.035
0.000
0.000
0. 125
0.000
0.000
0.000
0.000
0.017
0.043
0.034
0.042

1.171
-0.038

i----------


DAYTIME- I COLLECT
DAYTIME IC OLLECTOR


AMPIENT
TEMP
DEG F


COLLECTED
SOLAR
ENERGY
MILLION
BTU
i----------
0.000
0.000
0.033
0.031
0.025
0.000
0. 000
0.000
0.035
0.024
0.023
0.008
0.000
C.000
0.028
0.014
0.000
-0.000
0.030
0.009
C.000
0.000
0.042
0.000
0.000
00000
0.000
0.000
0.007
0.018
0.012
0.016

0.355

0.011
Q100
-----------


55
58
24
21
4*
30
32
39
28
26
21
22
28
37
24
30
21
19
19
27
40
36
37

41
35
41
42
45
39
34


33


* DENOTES UNAVAILABLE DATA.
& DENOTES NULL DATA.
N.A. DENOTES NOT APPLICABLE DATA.


ARRAY
EFFICIENCY


0 000
0.000
0 294
0 260
0 279
0 000
0.000
0 000
0.290
0,211
0 181
0.119
0.000
0 000
0 256
0.220
0.018
-0 000
0.228
0.178
C. 000
0.000
0.315
0.000
0.000
0.000
0.000
0 264
0.311
0 250
0.260


0.219

N1 00


SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM








SOLAR HEATING AND CCCLING DEMONSTRATION PROGRAM

MONTHLY REPORT
STORAGE PERFORMANCE

SITE: SADDLE HILLS TRUST LOT #77, MEDWAYMA 02053SOLAR/1039-79/01
REPORT PERIOD: JANUARY,1979
------------------------------------ ------------- ------- -
DAY ENERGY ENERGY CHANGE STORAGE STORAGE
OF TO FROM IN STORED AVERAGE EFFICIENCY
MONTH STORAGE STORAGE ENERGY TEMP
MILLION MILLION MILLION DEC F
BTU BTU BTU

1 N N N N N
2 O 0 o 0 0
3 T T T T T
4
5 A A A A A
6 P P P P P
7 P P P P P
8 L L L L L
9 I I I I I
10 C C C C C
11 A A A A A
0o 12 B B B B B
13 L L L L L
14 E E E E E
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
------------------------------------ ------- ----------- ---------- -------
SUM N.A. N.A. N.A. -

AVG N.A. N.A. N.A. I N.A. I N.A.
I . --I
NBS ID Q200 Q201 Q202 N108

DENOTES UNAVAILABLE DATA.
8 DENOTES NULL DATA.
N.A. DENOTES NOT APPLICABLE DATA.





SOLAR HEATING AND COOLING DEMONSTRATING PROGRAM


MONTHLY REPORT
HOT WATER SUBSYSTEM


SOLAR/1039-79/01


SITE: SADDLE HILLS TRUST LOT #77, MEDWAYVMA 02053
REPORT PERIOD: JANUARY,1979


---,I
DAY
OF
MON.


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

SUM

AVG

NBS-
NBS


HOT
WATER
LOAD
MILLION
BTU

0.104
0 090
0.064
0 099
0.104
0.086
0.026
0.000
0.000
0.000
0.000
0.029
0.097
0 032
0. 049
0.068
0.093
0.054
0.061
0.010
0.055
0.112
0.053
0 059
0.084
0,046
S0042
0.159
0.025
0 077
0 028

1.806

0.058

Q302


SOLAR
FR .OF
LOAD
PER
CENT

40
9
11
21
22
18
13
0
0
0
0
36
30
8
9
19
17
7
5
8
20
15
7
32
16
5
3
10
4
15
16


17

N300


SOLAR
ENERGY
USED
MILLION
BTU

0.000
0.000
0.030
0.028
0.023
0.000
0 000
0.0000
0.032
0.020
0.019
0.006
0,000
C.000
0.027
0.013
0.000
0.000
0.028
0.008
0.000
0.000
0 038
0.000
0.000
0.000
0.000
0.007
0.017
0.011
0.014'

0.321

0.010

0300


OPER
ENERGY

MILLION
BTU

N
0
T

A
P
P
L
I
C
A
B
L
E
















N.A.

N.A.

0303


AUX
THERMAL
USED
MILLION
BTU

0.049
0.093
0.069
0.110
0.073
0.087
0.036
0.017
0.016
0.016
0.016
0.037
0.087
0.044
0.054
0.065
0 103
0.061
0 082
0.040
0,061
0 096
0.094
0 052
0.086
0.065
0.063
0.134
0.060
0 071
0.034

1.971

0.064

0301


N.A.

N0A.

0305


AUX
ELECT
FUEL
MILLION
BTU

N
O
T

A
P
P
L
I
C
A
B
L
E


AUX
FOSSIL
FUEL
MILLION
BTU

0.082
0.156
0.115
0.184
0.122
0 144
0 060
0.028
00027
0 027
0.027
0.061
0.145
0.074
0.090
0.108
0.171
0.101
0.136
00067
0.102
0 160
0.157
0.087
0.143
0.108
0.105
09223
0 099
0.118
0.056

3.285

0.106

0306


ELECT
ENERGY
SAVINGS
MILLION
BTU

0.000
0.000
-0.004
-0.004
-0 003
0.000
0.000
0.000
-0.004
-0.004
-0.004
-0.002
0.000
0.000
-0.004
-0 0021
-0.0000
-00001
-0 004
-0.002
0.000



00000
-0.001
-0.000


-0.001
0.000
0.0 Co


-0.0015
-0.002
0.000
00000
-0.001
-0.002
-0.001
-0.002

-0.050

-0.002

0311


- ------- I-'---'-- ----I


FCSSIL
ENERGY
SAVINGS
MILLION
BTU

0.018
0.010
0.017
0.037
0 032
0 027
0.005
00000
0 000
0. 000
0. 000
0 020
0. 041
0 004
0 007
0. 026
0.023
0.005
00 007
0. 005
0.023
0. 020
0.014
0. 036
0.020
0.004
0.002
0.020
0.004
0 024
0.009

0.461

0. CIE

0313


* DENOTES UNAVAILABLE DATA.
8 DENOTES NULL DATA.
N.A. DENOTES NOT APPLICABLE DATA.


I


SUP.
%AT.
TEMP
DEG
F

50
47
48
50
46
46
44
45
45
45
45
45
44
51
47
44
43
46
45
47
44
48
45
44
45
46
42
44
45
45
45


46

N305


HOT
WAT.
TEMP'
DEG
F

142
141
142
148
149
149
154
154
154
154
154
1521
146
144
142
143
148
142
147
144
146
139
142
142
143
1451
140
144
148
146
142


146

N307


HOT
WATER
USED

GAL

132
115
79
149
104
94
29
0
0
0
0
33
112
38
64
80
107
65
82
19
62
166
91
71
99
54
51
181
29
86
34

2228

72

N308









SOLAR HEATING AND COOLING DEMONSTRATION PROGRAM

MONTHLY REPORT
ENVIRONMENTAL SUMMARY

SITE: SADDLE HILLS TRUST LOT #77, MEDWAYMA 02053
REPORT PERIOD: JANUARY 1979

DAY TOTAL DIFFUSE AMBIENT DAYTIME RELATIVE
OF INSOLATION INSOLATION TEMPERATURE AMBIENT HUMIDITY DIRI
MONTH TEMF
BTU/SQ.FT BTU/SQ.FT DEG F DEG F PERCENT DF

1 19 N 53 55 N
2 44 0 57 58 0
3 1450 T 25 24 T
4 1509 15 21
5 1159 A 16 A
6 375 P 24 30 P
7 73 P 30 32 P
8 31 L 42 39 L
9 1547 I 25 28 I
10 1438 C 20 26 C
11 1653 A 14 21 A
12 821 B 14 22 B
13 78 L 28 28 L
14 51 E 36 37 E
15 1404 22 24
16 797 24 30
17 266 16 21
18 707 15 19
19 1677 11 19
20 672 19 27
21 10 40 40
22 153 35 36
23 1711 32 37
24 298 32
25 9 40 41
26 114 36 35
27 233 39 41
28 356 37 42
29 732 40 45
30 611 37 39
31 811 31 34

SUM 20809 N.A.
------------- --------- -------------------------- --
AVG 671 N.A. 29 33 N.A.

NBS ID 0001 N113

* DENOTES UNAVAILABLE DATA.
a DENOTES NULL DATA.
N.A. DENOTES NOT APPLICABLE DATA.


SOLAR/1039-79/01


W IND
SECTION

GREFS

N
0
T

A
P
P
L
I
C
A
E
L
E


















N.A.
N115


I-------------
WIND
SPEED

M.P.H.

N
0
T

A
P
P
L
I
C
A
B
L
E


















N.A.
N114






























1411






UNIVERSITY OF FLORIDA
11111111111111111111111112 09052 0871111111111111111111
3 1262 09052 6087




Full Text
xml version 1.0 encoding UTF-8
REPORT xmlns http:www.fcla.edudlsmddaitss xmlns:xsi http:www.w3.org2001XMLSchema-instance xsi:schemaLocation http:www.fcla.edudlsmddaitssdaitssReport.xsd
INGEST IEID E6XXS5DR6_JSBEU2 INGEST_TIME 2014-04-09T23:54:09Z PACKAGE AA00013795_00002
AGREEMENT_INFO ACCOUNT UF PROJECT UFDC
FILES